Experimental study on wedge-bonded anchors for CFRP tendons under cyclic loading

被引:9
|
作者
Xie, Gui-hua [1 ,2 ]
Bian, Yu-long [1 ]
Feng, Qian-hong [1 ]
Wang, C. M. [2 ]
Liu, Rong-gui [1 ]
机构
[1] Jiangsu Univ, Fac Civil Engn & Mech, Dept Civil Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Univ Queensland, Sch Civil Engn, St Lucia, Qld 4072, Australia
基金
中国国家自然科学基金;
关键词
Wedge-bonded anchor; CFRP tendon; Fatigue damage; Stress level; Stress ratio; COMPOSITE ANCHORS; FATIGUE BEHAVIOR; RC BEAMS; FRP; PERFORMANCE; STEEL; SYSTEM; OPTIMIZATION; BRIDGES;
D O I
10.1016/j.conbuildmat.2019.117599
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is concerned with an experimental study on a wedge-bonded anchor for carbon fibre reinforced polymer (CFRP) tendons under cyclic loading. The adhesive reinforced by quartz sand was tested to be superior as a bonding material for the anchor when compared to the adhesive reinforced by ferrous powder or aluminate powder. Structural responses of the wedge-bonded anchor under cyclic loading were analyzed with regard to system slip, sleeve strain, temperature rise in the anchor zone and residual tensile load capacity. The results indicate that the maximum stress level and stress ratio influence significantly the fatigue performance of wedge-bonded anchors. A cyclic loading with a high stress ratio and low stress level is beneficial due to the synergetic effect of the components in the wedge-bonded anchors. However, enhancing the stress level or lowering the stress ratio leads to a larger slip, greater damage and more loading cycles are needed for the stabilization of wedge-bonded anchors. When the stress ratio exceeds 0.4 and the maximum stress is less than 0.5, damage in anchor zone is initiated and developed in the early stage of cyclic loading, but the anchor becomes stable finally. A large decrease in stress ratio may result in a continuous development of microstructural damage and the eventual failure of the anchor, accompanied by continuously increasing energy dissipation under cyclic loading. The axial strain of sleeve in a wedge-bonded anchor is influenced by the extent of damage evolution and the synergetic effect of anchor assemblies: thereby resulting in different trends in sleeve strain-cycle curves under different stress ratios and stress levels. The temperature rise may be pronounced at a loading frequency of 10 Hz or less, which is related to the stress ratio. The damage development in the wedge-bonded anchor with an infinite fatigue life was analyzed. The mechanism of fatigue damage in wedge-bonded anchors is different from that of adhesively bonded anchors. Moreover, wedge-bonded anchors have a stronger resistance against fatigue due to the interaction between the wedges and the other assemblies. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Prediction and optimization of stress distribution in bonded anchors for CFRP tendons
    Xie, Gui-hua
    Feng, Qian-hong
    Wang, C. M.
    Tang, Yong-sheng
    Liu, Rong-gui
    ENGINEERING STRUCTURES, 2019, 180 : 50 - 66
  • [2] Experimental Study on CFRP-to-Steel Bonded Interfaces under Quasi-Static Cyclic Loading
    Doroudi, Y.
    Fernando, D.
    Nguyen, V. T.
    Torres, J. P.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2019, 23 (04)
  • [3] CFRP-to-steel bonded joints subjected to cyclic loading: An experimental study
    Yang, Yongming
    Silva, Manuel A. G.
    Biscaia, Hugo
    Chastre, Carlos
    COMPOSITES PART B-ENGINEERING, 2018, 146 : 28 - 41
  • [4] Experimental study of precast segmental columns with unbonded tendons under cyclic loading
    Li, Chao
    Hao, Hong
    Zhang, Xihong
    Bi, Kaiming
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (03) : 319 - 334
  • [5] Experimental study on the bond behavior of CFRP-steel interfaces under quasi-static cyclic loading
    Pang, Yuyang
    Wu, Gang
    Wang, Haitao
    Su, Zhilong
    He, Xiaoyuan
    THIN-WALLED STRUCTURES, 2019, 140 : 426 - 437
  • [6] Bond-Slip Relationship for CFRP Sheets Externally Bonded to Concrete under Cyclic Loading
    Li, Ke
    Cao, Shuangyin
    Yang, Yue
    Zhu, Juntao
    MATERIALS, 2018, 11 (03):
  • [7] Experimental and analytical investigation into the stress performance of composite anchors for CFRP tendons
    Cai, Dong-sheng
    Yin, Jie
    Liu, Rong-gui
    COMPOSITES PART B-ENGINEERING, 2015, 79 : 530 - 534
  • [8] Experimental investigation of RC shear walls with openings under cyclic loading repaired with externally bonded CFRP strips
    Ozdemir, Anil
    Kopraman, Yagmur
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2023, 24 (01)
  • [9] Optimal Design Method and Experiment for Improved Wedge-Type Anchors of Large-Diameter Smooth CFRP Tendons
    Zhuge, Ping
    Tao, Guocheng
    Jie, Zhiyu
    Ding, Yong
    Wang, Bing
    APPLIED COMPOSITE MATERIALS, 2021, 28 (06) : 1997 - 2019
  • [10] Behavior of cracked steel plates strengthened with adhesively bonded CFRP laminates under fatigue Loading: Experimental and analytical study
    Doroudi, Y.
    Fernando, D.
    Hosseini, A.
    Ghafoori, E.
    COMPOSITE STRUCTURES, 2021, 266