MR angiography of the renal arteries: Intraindividual comparison of double-dose contrast enhancement at 1.5 T with standard dose at 3 T

被引:7
作者
Herborn, Christoph U. [1 ,2 ]
Runge, Val M. [2 ]
Watkins, David M. [2 ]
Gendron, Jilene M. [2 ]
Naul, L. Gill [2 ]
机构
[1] Med Univ Ctr Hamburg, Med Prevent Ctr, D-20251 Hamburg, Germany
[2] Scott & White Mem Hosp & Clin, Dept Radiol, Temple, TX USA
关键词
high magnetic field strength; MR angiography; renal arterial stenosis;
D O I
10.2214/AJR.07.2486
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare prospectively and within subjects use of 0.1 mmol/kg of gadodiamide at 3 T with use of 0.2 mmol/kg of gadodiamide at 1.5 T for MR angiography of the renal arteries. SUBJECTS AND METHODS. Twenty-two patients ( 14 men, eight women; mean age, 66.5 years) underwent two MR angiographic examinations of the renal arteries separated by at least 24 hours on whole-body 1.5- and 3-T MRI systems with a phase-encoded 3D spoiled breath-hold pulse sequence. Two radiologists blinded to the dose of contrast material assessed all image data in consensus for renal arterial disease and for image quality on a five-point Lik-ert-type scale. Quantitative evaluation ( vessel signal-to-noise ratio and vessel-muscle contrast-to-noise ratio) was performed by a third radiologist. RESULTS. Five renal arterial stenoses were detected with both techniques. The difference in mean image quality for the two doses and field strengths was not statistically significant. Overall vessel length and intraparenchymal branches, however, were better visualized with the double dose at 1.5 T. Signal-to-noise and contrast-to-noise ratios were significantly higher (both, p < 0.05) with the double dose at 1.5 T ( 125.7 and 64.2, respectively) compared with the standard dose at 3 T (112.3 and 59.7). CONCLUSION. MR angiography can be performed with high diagnostic image quality at 3 T with 0.1 mmol/kg of gadodiamide. Signal-to-noise and contrast-to-noise ratios are higher with a double dose at 1.5 T.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 40 条
[21]   High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE) [J].
Walter, C ;
Philippi, G ;
Westerhausen, R ;
Kooijman, H ;
Hoffmann, HG ;
Busch, HP .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (09) :1244-1250
[22]   MR Angiography at 3 T of Peripheral Arterial Disease: A Randomized Prospective Comparison of Gadoterate Meglumine and Gadobutrol [J].
Loewe, Christian ;
Arnaiz, Javier ;
Krause, Denis ;
Marti-Bonmati, Luis ;
Haneder, Stefan ;
Kramer, Ulrich .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) :1311-1321
[23]   Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function [J].
Park, Sung Yoon ;
Kim, Chan Kyo ;
Kim, EunJu ;
Park, Byung Kwan .
EUROPEAN RADIOLOGY, 2015, 25 (02) :533-540
[24]   Vascular Thoracic Outlet Syndrome: Protocol Design and Diagnostic Value of Contrast-Enhanced 3D MR Angiography and Equilibrium Phase Imaging on 1.5-and 3-T MRI Scanners [J].
Ersoy, Hale ;
Steigner, Michael L. ;
Coyner, Karl B. ;
Gerhard-Herman, Marie D. ;
Rybicki, Frank J. ;
Bueno, Raphael ;
Nguyen, Louis L. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) :1180-1187
[25]   Comparison of 1.5 T and 3 T magnetic resonance angiography for detecting cerebral aneurysms using deep learning-based computer-assisted detection software [J].
Tajima, Taku ;
Akai, Hiroyuki ;
Yasaka, Koichiro ;
Kunimatsu, Akira ;
Yoshioka, Naoki ;
Akahane, Masaaki ;
Ohtomo, Kuni ;
Abe, Osamu ;
Kiryu, Shigeru .
NEURORADIOLOGY, 2023, 65 (10) :1473-1482
[26]   Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT) for Fast Imaging of Extracranial Arteries in Acute Ischemic Stroke at 3T [J].
Pennig, Lenhard ;
Kabbasch, Christoph ;
Hoyer, Ulrike Cornelia Isabel ;
Lennartz, Simon ;
Zopfs, David ;
Goertz, Lukas ;
Laukamp, Kai Roman ;
Wagner, Anton ;
Grunz, Jan-Peter ;
Doerner, Jonas ;
Persigehl, Thorsten ;
Weiss, Kilian ;
Borggrefe, Jan .
CLINICAL NEURORADIOLOGY, 2021, 31 (03) :815-826
[27]   Performance of 3-T Nonenhanced Whole-Heart bSSFP Coronary MR Angiography: A Comparison with 3-T Modified Dixon Water-Fat Separation Sequence [J].
Yuan, Yong ;
Jiang, Yue ;
Lu, Guang Ming ;
Jin, Dongsheng ;
Chen, Wei Bo ;
Wang, Baijun ;
Chen, Tong ;
Hu, Qiuju ;
Zhu, Jiajia ;
Zhao, Yane .
RADIOLOGY-CARDIOTHORACIC IMAGING, 2025, 7 (02)
[28]   Low-Dose, Time-Resolved, Contrast-Enhanced 3D MR Angiography in the Assessment of the Abdominal Aorta and Its Major Branches at 3 Tesla [J].
Kramer, Ulrich ;
Fenchel, Michael ;
Laub, Gerhard ;
Seeger, Achim ;
Klumpp, Bernhard ;
Bretschneider, Christiane ;
Finn, J. Paul ;
Claussen, Claus D. ;
Miller, Stephan .
ACADEMIC RADIOLOGY, 2010, 17 (05) :564-576
[29]   Contrast Material for Abdominal Dynamic Contrast-Enhanced 3D MR Angiography With Parallel Imaging: Intraindividual Equimolar Comparison of a Macrocyclic 1.0 M Gadolinium Chelate and a Linear Ionic 0.5 M Gadolinium Chelate [J].
Hadizadeh, Dariusch Reza ;
Von Falkenhausen, Marcus ;
Kukuk, Guido Matthias ;
Schoeneseiffen, Katherina ;
Gieseke, Juergen ;
Schild, Hans Heinz ;
Willinek, Winfried Albert .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) :821-829
[30]   Whole-body MR Angiography with Body Coil Acquisition at 3 T in Patients with Peripheral Arterial Disease Using the Contrast Agent Gadofosveset Trisodium [J].
Nielsen, Yousef W. ;
Eiberg, Jonas P. ;
Logager, Vibeke B. ;
Hansen, Marc A. ;
Schroeder, Torben V. ;
Thomsen, Henrik S. .
ACADEMIC RADIOLOGY, 2009, 16 (06) :654-661