Objective: A randomized study was performed to compare the efficacy, safety and acceptability of a new model of an intracervical/intrauterine contraceptive device (ICD) releasing 20 mu g of levonorgestrel (LNG) per day. Methods: The LNG-ICD was inserted in Group I into the cervical canal and in Group II into the uterine cavity. Group I included 151 women (age, 18-43 years) whereas Group II included 147 (age, 19-43 years). The number of nulliparous women was 145. Results: The 5-year results are presented here. The results showed a total continuation rate of 50%; the continuation rate in the cervical group and that in the uterine group were 53.6% and 46.3%, respectively - the difference being statistically insignificant (P = .3593). The main reason for termination was a wish for pregnancy, which is explained by the relatively young age and degree of milliparity of the study population. During the first year, two pregnancies occurred in both groups. Two of these were ectopic, one in each group. The other two occurred after unnoticed expulsions. Thereafter, no pregnancies occurred. The cumulative gross rate for pregnancy was 1.3 and the Pearl index at 5 years was 0.425. The total expulsion rate was relatively high (11.1%). Expulsions occurring during the first few months of the first year were related to insertion. Removals because of bleeding and because of amenorrhea were low, the combined gross rate being 5.7 and the Pearl rate 1.8 at 5 years. Also, the gross rate of infection was low (0.7). The continuation was high in spite of a high rate of removals for planning pregnancy (15.4). Conclusions: The method is safe and effective. There were only minor differences between the groups. There were no perforations and the incidence of infection was low. The device can also be used by young nulliparous women. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:342 / 345
页数:4
相关论文
共 50 条
  • [21] Use of the levonorgestrel-releasing intrauterine system: an Austrian perspective
    Concin, Hans
    Boesch, Hubert
    Hintermueller, Peter
    Hohlweg, Thomas
    Mursch-Edlmayr, Gerhard
    Pinnisch, Bettina
    Schmidl-Amann, Sigrid
    Schulz-Greinwald, Gunda
    Unterlerchner, Dagmar
    Wagner, Teresa
    Mattle, Verena
    Wildt, Ludwig
    Fiala, Christian
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2009, 21 : S1 - S9
  • [22] Levonorgestrel-Releasing Intrauterine Device Use Can Be a Treatment Option in Symptomatic Patients with Isthmocele
    Fatma Ketenci Gencer
    Burcu Dincgez
    Semra Yuksel
    Reproductive Sciences, 2022, 29 : 2977 - 2982
  • [23] Simple and Novel Technique of Fixation for Levonorgestrel-Releasing Intrauterine Device for the Treatment of Uterine Adenomyosis
    Zhou, Jieli
    Han, Wenling
    Xie, Xiaoying
    Li, Longyu
    Chen, Jinshi
    INDIAN JOURNAL OF SURGERY, 2024, 86 (06) : 1259 - 1261
  • [24] Levonorgestrel-Releasing Intrauterine Device Use Can Be a Treatment Option in Symptomatic Patients with Isthmocele
    Gencer, Fatma Ketenci
    Dincgez, Burcu
    Yuksel, Semra
    REPRODUCTIVE SCIENCES, 2022, 29 (10) : 2977 - 2982
  • [25] The impact of using the levonorgestrel-releasing intrauterine device on the incidence of acne in adolescents and young women
    de Oliveira, Elaine Cristina Fontes
    Senra, Janaina Campos
    Rocha, Ana Luiza Lunardi
    EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2024, 29 (05) : 233 - 238
  • [26] COMPARISON OF PAIN LEVEL DURING AND AFTER INTRAUTERINE DEVICE INSERTION: LEVONORGESTREL-RELEASING INTRAUTERINE SYSTEM VERSUS THE COPPER T INTRAUTERINE DEVICE
    Cirstoiu, Monica
    Munteanu, Octavian
    Antoniac, Iulian
    Cirstoiu, Catalin
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2016, 15 (05): : 965 - 972
  • [27] Levonorgestrel-releasing intrauterine device can be used in oocyte donors during ovarian stimulation
    SoderstromAnttila, V
    Tiitinen, A
    Hovatta, O
    HUMAN REPRODUCTION, 1997, 12 (03) : 491 - 495
  • [28] Experience and levels of satisfaction with the levonorgestrel-releasing intrauterine system in China: a prospective multicenter survey
    Zhao, Shuping
    Deng, Jihong
    Wang, Yan
    Bi, Shiliang
    Wang, Xiaoye
    Qin, Wen
    Huang, Zirong
    Li, Li
    Mi, Xin
    Han, Liping
    Chang, Qing
    Li, Jian
    PATIENT PREFERENCE AND ADHERENCE, 2014, 8 : 1449 - 1455
  • [29] Experience with same-day placement of the 52 mg levonorgestrel-releasing intrauterine system
    Castano, Paula M.
    Westhoff, Carolyn L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (04)
  • [30] Pain Perception during Levonorgestrel-releasing Intrauterine Device Insertion in Nulliparous Women: A Systematic Review
    Anthoulakis, Christos
    Iordanidou, Eirini
    Vatopoulou, Anastasia
    JOURNAL OF PEDIATRIC AND ADOLESCENT GYNECOLOGY, 2018, 31 (06) : 549 - +