FAR-WALL PSEUDOENHANCEMENT DURING CONTRAST-ENHANCED ULTRASOUND OF THE CAROTID ARTERIES: CLINICAL DESCRIPTION AND IN VITRO REPRODUCTION

被引:60
作者
ten Kate, Gerrit L. [1 ,2 ]
Renaud, Guillaume G. J. [3 ]
Akkus, Zeynettin [3 ]
van den Oord, Stijn C. H. [2 ,3 ]
ten Cate, Folkert J. [2 ]
Shamdasani, Vijay [4 ]
Entrekin, Rob R. [4 ]
Sijbrands, Eric J. G. [1 ]
de Jong, Nico [3 ]
Bosch, Johan G. [3 ]
Schinkel, Arend F. L. [1 ,2 ]
van der Steen, Antonius F. W. [3 ]
机构
[1] Erasmus MC, Dept Internal Med, Div Pharmacol Vasc & Metab Dis, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[3] Erasmus MC, Dept Biomed Engn, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[4] Philips Healthcare, Bothell, WA USA
关键词
Attenuation; Carotid artery; Contrast-enhanced ultrasound; Imaging artifact; Microbubbles; Nonlinear propagation; Pseudoenhancement; Vascular ultrasound; PRESSURE-DEPENDENT ATTENUATION; VASA VASORUM; MICROBUBBLES; SCATTERING; AGENTS;
D O I
10.1016/j.ultrasmedbio.2011.12.019
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The present study describes the presence of pseudoenhancement during contrast-enhanced ultrasound (CEUS) imaging of human carotid arteries and the reproduction of this pseudoenhancement in vitro. Seventy patients underwent bilateral CEUS examination of the carotid arteries using a Philips iU22 ultrasound system equipped with a L9-3 ultrasound probe and SonoVue microbubble contrast. During CEUS of the carotid arteries, we identified enhancement in close proximity to the far wall, parallel to the main lumen. The location of this enhancement does not correlate to the anatomical location of a parallel vessel. To corroborate the hypothesis that this is a pseudoenhancement artifact, the enhancement was recreated in a tissue-mimicking material phantom, using the same ultrasound system, settings and contrast agent as the patient study. The phantom study showed that pseudoenhancement may be present during vascular CEUS and that the degree of pseudoenhancement is influenced by the size and concentration of the microbubbles. During vascular CEUS, identification of the artifact is important to prevent misinterpretation of enhancement in and near the far wall. (E-mail: g.l.tenkate@erasmusmc.nl) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:593 / 600
页数:8
相关论文
共 19 条
  • [11] Characteristics of SonoVue™
    Schneider, M
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (07): : 743 - 746
  • [12] Contrast-Enhanced Ultrasound Imaging of the Vasa Vasorum
    Staub, Daniel
    Schinkel, Arend F. L.
    Coll, Blai
    Coli, Stefano
    van der Steen, Antonius F. W.
    Reed, Jess D.
    Krueger, Christian
    Thomenius, Kai E.
    Adam, Dan
    Sijbrands, Eric J.
    ten Cate, Folkert J.
    Feinstein, Steven B.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2010, 3 (07) : 761 - 771
  • [13] Frequency and pressure dependent attenuation and scattering by microbubbles
    Tang, Meng-Xing
    Eckersley, Robert J.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (01) : 164 - 168
  • [14] Nonlinear propagation of ultrasound through microbubble contrast agents and implications for Imaging
    Tang, Meng-Xing
    Eckersley, Robert J.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (12) : 2406 - 2415
  • [15] EFFECTS OF NONLINEAR PROPAGATION IN ULTRASOUND CONTRAST AGENT IMAGING
    Tang, Meng-Xing
    Kamiyama, Naohisa
    Eckersley, Robert J.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (03) : 459 - 466
  • [16] Pressure-dependent attenuation with microbubbles at low mechanical index
    Tang, MX
    Eckersley, RJ
    Noble, JA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03) : 377 - 384
  • [17] Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories
    Teirlinck, CJPM
    Bezemer, RA
    Kollmann, C
    Lubbers, J
    Hoskins, PR
    Fish, P
    Fredfeldt, KE
    Schaarschmidt, UG
    [J]. ULTRASONICS, 1998, 36 (1-5) : 653 - 660
  • [18] Measurements of the nonlinearity parameter B/A of contrast agents
    Wu, JR
    Tong, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01) : 153 - 159
  • [19] Pseudoenhancement Within the Local Ablation Zone of Hepatic Tumors Due to a Nonlinear Artifact on Contrast-Enhanced Ultrasound
    Yu, Hojun
    Jang, Hyun-Jung
    Kim, Tae Kyoung
    Khalili, Korosh
    Williams, Ross
    Lueck, Gord
    Hudson, John
    Burns, Peter N.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) : 653 - 659