FAR-WALL PSEUDOENHANCEMENT DURING CONTRAST-ENHANCED ULTRASOUND OF THE CAROTID ARTERIES: CLINICAL DESCRIPTION AND IN VITRO REPRODUCTION

被引:60
作者
ten Kate, Gerrit L. [1 ,2 ]
Renaud, Guillaume G. J. [3 ]
Akkus, Zeynettin [3 ]
van den Oord, Stijn C. H. [2 ,3 ]
ten Cate, Folkert J. [2 ]
Shamdasani, Vijay [4 ]
Entrekin, Rob R. [4 ]
Sijbrands, Eric J. G. [1 ]
de Jong, Nico [3 ]
Bosch, Johan G. [3 ]
Schinkel, Arend F. L. [1 ,2 ]
van der Steen, Antonius F. W. [3 ]
机构
[1] Erasmus MC, Dept Internal Med, Div Pharmacol Vasc & Metab Dis, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[3] Erasmus MC, Dept Biomed Engn, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[4] Philips Healthcare, Bothell, WA USA
关键词
Attenuation; Carotid artery; Contrast-enhanced ultrasound; Imaging artifact; Microbubbles; Nonlinear propagation; Pseudoenhancement; Vascular ultrasound; PRESSURE-DEPENDENT ATTENUATION; VASA VASORUM; MICROBUBBLES; SCATTERING; AGENTS;
D O I
10.1016/j.ultrasmedbio.2011.12.019
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The present study describes the presence of pseudoenhancement during contrast-enhanced ultrasound (CEUS) imaging of human carotid arteries and the reproduction of this pseudoenhancement in vitro. Seventy patients underwent bilateral CEUS examination of the carotid arteries using a Philips iU22 ultrasound system equipped with a L9-3 ultrasound probe and SonoVue microbubble contrast. During CEUS of the carotid arteries, we identified enhancement in close proximity to the far wall, parallel to the main lumen. The location of this enhancement does not correlate to the anatomical location of a parallel vessel. To corroborate the hypothesis that this is a pseudoenhancement artifact, the enhancement was recreated in a tissue-mimicking material phantom, using the same ultrasound system, settings and contrast agent as the patient study. The phantom study showed that pseudoenhancement may be present during vascular CEUS and that the degree of pseudoenhancement is influenced by the size and concentration of the microbubbles. During vascular CEUS, identification of the artifact is important to prevent misinterpretation of enhancement in and near the far wall. (E-mail: g.l.tenkate@erasmusmc.nl) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:593 / 600
页数:8
相关论文
共 19 条
  • [1] On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent
    Bouakaz, A
    de Jong, N
    Cachard, C
    Jouini, K
    [J]. ULTRASONICS, 1998, 36 (1-5) : 703 - 708
  • [2] Pressure-dependent attenuation in ultrasound contrast agents
    Chen, Q
    Zagzebski, J
    Wilson, T
    Stiles, T
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (08) : 1041 - 1051
  • [3] PRESSURE-DEPENDENT ATTENUATION AND SCATTERING OF PHOSPHOLIPID-COATED MICROBUBBLES AT LOW ACOUSTIC PRESSURES
    Emmer, Marcia
    Vos, Hendrik J.
    Goertz, David E.
    van Wamel, Annemieke
    Versluis, Michel
    de Jong, Nico
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (01) : 102 - 111
  • [4] Contrast ultrasound imaging of the carotid artery vasa vasorum and atherosclerotic plaque neovascularization
    Feinstein, Steven B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) : 236 - 243
  • [5] Influence of bubble size distribution on the echogenicity of ultrasound contrast agents -: A study of SonoVue™
    Gorce, JM
    Arditi, M
    Schneider, M
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (11) : 661 - 671
  • [6] Carotid arteries: Contrast-enhanced US angiography preliminary clinical experience
    Kono, Y
    Pinnell, SP
    Sirlin, CB
    Sparks, SR
    Georgy, B
    Wong, W
    Mattrey, RF
    [J]. RADIOLOGY, 2004, 230 (02) : 561 - 568
  • [7] Effect of contrast enhancement on measurement of carotid artery intimal medial thickness
    Macioch, JE
    Katsamakis, CD
    Robin, J
    Liebson, PR
    Meyer, PM
    Geohas, C
    Raichlen, JS
    Davidson, MH
    Feinstein, SB
    [J]. VASCULAR MEDICINE, 2004, 9 (01) : 7 - 12
  • [8] The vasa vasorum in diseased and nondiseased arteries
    Mulligan-Kehoe, Mary Jo
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2010, 298 (02): : H295 - H305
  • [9] Principles of Cerebral Ultrasound Contrast Imaging
    Powers, Jeff
    Averkiou, Michalakis
    Bruce, Matthew
    [J]. CEREBROVASCULAR DISEASES, 2009, 27 (SUPPL 2) : 14 - 24
  • [10] The dynamic vasa vasorum
    Ritman, Erik L.
    Lerman, Amir
    [J]. CARDIOVASCULAR RESEARCH, 2007, 75 (04) : 649 - 658