Impact of different building ventilation modes on occupant expectations of the main IEQ factors

被引:64
|
作者
Kim, Jungsoo [1 ]
de Dear, Richard [1 ]
机构
[1] Univ Sydney, Fac Architecture Design & Planning, Sydney, NSW 2006, Australia
关键词
Indoor environmental quality; Occupant satisfaction; Kano's model; Adaptive opportunity; Natural ventilation; Thermal comfort; THERMAL COMFORT; CUSTOMER SATISFACTION; OFFICE BUILDINGS; BEHAVIOR; ADAPTATION;
D O I
10.1016/j.buildenv.2012.05.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study explores the relationship between the perceived performance of specific IEQ factors and occupants' overall satisfaction with their workspace. In particular we examine the influence of ventilation system type (i.e. Air-Conditioned AC, Mixed-Mode MM, Naturally Ventilated NV) on that relationship. Statistical analyses were conducted on the post-occupancy survey database from the University of California at Berkeley's Center for Built Environment (CBE) to estimate the relative importance of individual IEQ factors on occupants' overall satisfaction, depending on whether or not the occupants were satisfied with the IEQ factor in question. Based on these analyses, 15 IEQ factors were classified as Basic Factors, Bonus Factors or Proportional Factors, according to their relationship with overall satisfaction, as described in Kano's satisfaction model. We found that the classification of some IEQ factors differed for the occupants of AC, MM and NV buildings, suggesting that occupants of buildings with different ventilation types have different expectations, and respond in different ways to various aspects of the indoor environment. A noticeable difference was in thermal environmental conditions: in NV buildings, good thermal conditions were associated with significantly enhanced overall satisfaction (i.e. strong positive impact), but there was little discernible adverse impact, even when thermal performance was deemed to be poor. In AC buildings, on the other hand, thermal conditions were more directly associated with negative overall evaluations of workspace by occupants (i.e. greater negative impact than positive impact). Finally, in MM buildings, thermal conditions exerted both positive and negative impacts of comparable intensities on overall satisfaction. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 193
页数:10
相关论文
共 15 条
  • [1] Occupant Expectations on the Main IEQ Factors at Workspace: The Studies of Private Preschool Buildings
    Salleh, Naziah Muhamad
    Salim, Nuzaihan Aras Agus
    Kamaruzzaman, Syahrul Nizam
    4TH INTERNATIONAL BUILDING CONTROL CONFERENCE 2016 (IBCC 2016), 2016, 66
  • [2] Impact of Heating Control Strategy and Occupant Behavior on the Energy Consumption in a Building with Natural Ventilation in Poland
    Kaminska, Aniela
    ENERGIES, 2019, 12 (22)
  • [3] Respiratory Physiology and the Impact of Different Modes of Ventilation on the Photoplethysmographic Waveform
    Alian, Aymen A.
    Shelley, Kirk H.
    SENSORS, 2012, 12 (02): : 2236 - 2254
  • [4] Ventilation rates in naturally ventilated primary schools in the UK; Contextual, Occupant and Building-related (COB) factors
    Korsavi, Sepideh Sadat
    Montazami, Azadeh
    Mumovic, Dejan
    BUILDING AND ENVIRONMENT, 2020, 181 (181)
  • [5] Exploring the impact of different parameterisations of occupant-related internal loads in building energy simulation
    Ward, Rebecca
    Choudhary, Ruchi
    Heo, Yeonsook
    Rysanek, Adam
    ENERGY AND BUILDINGS, 2016, 123 : 92 - 105
  • [6] Impact of different supply modes of stratum ventilation on airflow and contaminant distribution characteristics
    Lu, Yalin
    Liu, Jian
    Lin, Zhang
    BUILDING AND ENVIRONMENT, 2023, 236
  • [7] Field measurements on indoor air quality of a residential building in Xi'an under different ventilation modes in winter
    Sui, Xuemin
    Tian, Zhongjie
    Liu, Huitao
    Chen, Hao
    Wang, Dong
    JOURNAL OF BUILDING ENGINEERING, 2021, 42
  • [8] The impact of different modes of noninvasive ventilation on hemodynamics and regional cerebral and splanchnic oximetry in the premature newborn
    Ali, Yaser A. H.
    Elsayed, Yasser N.
    Srinivasan, Ganesh
    Seshia, Mary M. K.
    Al-Ethawi, Yahya
    Baier, Ronald John
    JOURNAL OF CLINICAL NEONATOLOGY, 2016, 5 (03) : 179 - 182
  • [9] The Effects of Ecological Factors on the Main Medicinal Components of Dendrobium officinale under Different Cultivation Modes
    Yuan, Yingdan
    Tang, Xinggang
    Jia, Zhaohui
    Li, Chong
    Ma, Jieyi
    Zhang, Jinchi
    FORESTS, 2020, 11 (01):
  • [10] THE IMPACT OF DIFFERENT VENTILATION LEVELS AND FLUORESCENT LIGHTING TYPES ON BUILDING ILLNESS - AN EXPERIMENTAL-STUDY
    STERLING, E
    STERLING, T
    CANADIAN JOURNAL OF PUBLIC HEALTH-REVUE CANADIENNE DE SANTE PUBLIQUE, 1983, 74 (06): : 385 - 392