Design and Validation of a High-Throughput Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry Method for Quantification of Hepcidin in Human Plasma

被引:19
作者
Anderson, Damon S. [1 ,5 ,7 ]
Kirchner, Marc [1 ,5 ,7 ]
Kellogg, Mark [2 ,5 ]
Kalish, Leslie A. [3 ,6 ]
Jeong, Jee-Yeong [4 ]
Vanasse, Gary [4 ]
Berliner, Nancy [4 ]
Fleming, Mark D. [1 ,5 ]
Steen, Hanno [1 ,5 ,7 ]
机构
[1] Childrens Hosp Boston, Dept Pathol, Boston, MA 02115 USA
[2] Childrens Hosp Boston, Dept Lab Med, Boston, MA 02115 USA
[3] Childrens Hosp Boston, Clin Res Program, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Dept Med, Boston, MA 02115 USA
[5] Harvard Univ, Sch Med, Dept Pathol, Boston, MA 02115 USA
[6] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
[7] Childrens Hosp Boston, Prote Ctr, Boston, MA 02115 USA
关键词
SERUM HEPCIDIN; HUMAN URINE; PEPTIDE; DISEASE; INFLAMMATION; HORMONE; ANEMIA; COHORT; BLOOD;
D O I
10.1021/ac2020905
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Disorders of iron metabolism affect over a billion people worldwide. The circulating peptide hormone hepcidin, the central regulator of iron distribution in mammals, holds great diagnostic potential for an array of iron-associated disorders, including iron loading (beta-thalassemia), iron overload (hereditary hemochromatosis), and iron deficiency diseases. We describe a novel high-throughput matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry assay for quantification of hepcidin in human plasma. This assay involves enrichment using a functionalized MALDI chip, a novel solvent-detergent precipitation buffer, and quantification using a stable isotope labeled internal standard. The linear range of hepcidin in plasma was 1-120 nM, with a low limit of quantification (LOQ) (1 nM), high accuracy (<15% relative error (RE)), and high precision (intraday average 5.52-18.48% coefficient of variation (CV) and interday 9.32-14.83% CV). The assay showed strong correlation with an established hepcidin immunoassay (Spearman; R-2 = 0.839 n = 93 ethylenediaminetetraacetic acid (EDTA) plasma). A collection of normal healthy pediatric samples (range 3.8-32.5 ng/mL; mean 12.9 ng/mL; n = 119) showed significant differences from an adult collection (range 1.8-48.7 ng/mL; mean 16,1 ng/mL; n = 95; P = 0.0096). We discuss these preliminary reference ranges and correlations with additional parameters in light of the utility and limitations of hepcidin measurements as a stand-alone diagnostic and as a tool for therapeutic intervention.
引用
收藏
页码:8357 / 8362
页数:6
相关论文
共 31 条
  • [1] High-Throughput Matrix-Assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry Method for Quantification of Hepcidin in Human Urine
    Anderson, Damon S.
    Heeney, Matthew M.
    Roth, Udo
    Menzel, Christoph
    Fleming, Mark D.
    Steen, Hanno
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (04) : 1551 - 1555
  • [2] [Anonymous], 2010, HEM CLIN REF RANG RE
  • [3] Plasma hepcidin levels are elevated but responsive to erythropoietin therapy in renal disease
    Ashby, Damien R.
    Gale, Daniel P.
    Busbridge, Mark
    Murphy, Kevin G.
    Duncan, Neill D.
    Cairns, Tom D.
    Taube, David H.
    Bloom, Stephen R.
    Tam, Frederick W. K.
    Chapman, Richard S.
    Maxwell, Patrick H.
    Choi, Peter
    [J]. KIDNEY INTERNATIONAL, 2009, 75 (09) : 976 - 981
  • [4] Quantification of hepcidin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Bansal, Sukhvinder S.
    Halket, John M.
    Fusova, Jane
    Bomford, Adrian
    Simpson, Robert J.
    Vasavda, Nisha
    Thein, Swee Lay
    Hider, Robert C.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (11) : 1531 - 1542
  • [5] Quantitation of hepcidin in human urine by liquid chromatography-mass spectrometry
    Bansal, Sukhvinder S.
    Halket, John M.
    Bomford, Adrian
    Simpson, Robert J.
    Vasavda, Nisha
    Thein, Swee Lay
    Hider, Robert C.
    [J]. ANALYTICAL BIOCHEMISTRY, 2009, 384 (02) : 245 - 253
  • [6] Solvent/detergent treatment of human plasma -: A very robust method for virus inactivation.: Validated virus safety of OCTAPLAS®
    Blesert, L
    Suhartono, H
    [J]. VOX SANGUINIS, 1998, 74 : 207 - 212
  • [7] Bozzini C, 2002, CLIN CHEM, V48, P622
  • [8] Robustness of solvent/detergent treatment of plasma derivatives: a data collection from Plasma Protein Therapeutics Association member companies
    Dichtelmueller, Herbert O.
    Biesert, Lothar
    Fabbrizzi, Fabrizio
    Gajardo, Rodrigo
    Groener, Albrecht
    von Hoegen, Ilka
    Jorquera, Juan I.
    Kempf, Christoph
    Kreil, Thomas R.
    Pifat, Dominique
    Osheroff, Wendy
    Poelsler, Gerhard
    [J]. TRANSFUSION, 2009, 49 (09) : 1931 - 1943
  • [9] Hepcidin - a regulator of intestinal iron absorption and iron recycling by macrophages
    Ganz, T
    [J]. BEST PRACTICE & RESEARCH CLINICAL HAEMATOLOGY, 2005, 18 (02) : 171 - 182
  • [10] Immunoassay for human serum hepcidin
    Ganz, Tomas
    Olbina, Gordana
    Girelli, Domenico
    Nemeth, Elizabeta
    Westerman, Mark
    [J]. BLOOD, 2008, 112 (10) : 4292 - 4297