Design and Validation of a High-Throughput Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry Method for Quantification of Hepcidin in Human Plasma

被引:19
作者
Anderson, Damon S. [1 ,5 ,7 ]
Kirchner, Marc [1 ,5 ,7 ]
Kellogg, Mark [2 ,5 ]
Kalish, Leslie A. [3 ,6 ]
Jeong, Jee-Yeong [4 ]
Vanasse, Gary [4 ]
Berliner, Nancy [4 ]
Fleming, Mark D. [1 ,5 ]
Steen, Hanno [1 ,5 ,7 ]
机构
[1] Childrens Hosp Boston, Dept Pathol, Boston, MA 02115 USA
[2] Childrens Hosp Boston, Dept Lab Med, Boston, MA 02115 USA
[3] Childrens Hosp Boston, Clin Res Program, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Dept Med, Boston, MA 02115 USA
[5] Harvard Univ, Sch Med, Dept Pathol, Boston, MA 02115 USA
[6] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
[7] Childrens Hosp Boston, Prote Ctr, Boston, MA 02115 USA
关键词
SERUM HEPCIDIN; HUMAN URINE; PEPTIDE; DISEASE; INFLAMMATION; HORMONE; ANEMIA; COHORT; BLOOD;
D O I
10.1021/ac2020905
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Disorders of iron metabolism affect over a billion people worldwide. The circulating peptide hormone hepcidin, the central regulator of iron distribution in mammals, holds great diagnostic potential for an array of iron-associated disorders, including iron loading (beta-thalassemia), iron overload (hereditary hemochromatosis), and iron deficiency diseases. We describe a novel high-throughput matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry assay for quantification of hepcidin in human plasma. This assay involves enrichment using a functionalized MALDI chip, a novel solvent-detergent precipitation buffer, and quantification using a stable isotope labeled internal standard. The linear range of hepcidin in plasma was 1-120 nM, with a low limit of quantification (LOQ) (1 nM), high accuracy (<15% relative error (RE)), and high precision (intraday average 5.52-18.48% coefficient of variation (CV) and interday 9.32-14.83% CV). The assay showed strong correlation with an established hepcidin immunoassay (Spearman; R-2 = 0.839 n = 93 ethylenediaminetetraacetic acid (EDTA) plasma). A collection of normal healthy pediatric samples (range 3.8-32.5 ng/mL; mean 12.9 ng/mL; n = 119) showed significant differences from an adult collection (range 1.8-48.7 ng/mL; mean 16,1 ng/mL; n = 95; P = 0.0096). We discuss these preliminary reference ranges and correlations with additional parameters in light of the utility and limitations of hepcidin measurements as a stand-alone diagnostic and as a tool for therapeutic intervention.
引用
收藏
页码:8357 / 8362
页数:6
相关论文
共 31 条
[1]   High-Throughput Matrix-Assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry Method for Quantification of Hepcidin in Human Urine [J].
Anderson, Damon S. ;
Heeney, Matthew M. ;
Roth, Udo ;
Menzel, Christoph ;
Fleming, Mark D. ;
Steen, Hanno .
ANALYTICAL CHEMISTRY, 2010, 82 (04) :1551-1555
[2]  
[Anonymous], 2010, HEM CLIN REF RANG RE
[3]   Plasma hepcidin levels are elevated but responsive to erythropoietin therapy in renal disease [J].
Ashby, Damien R. ;
Gale, Daniel P. ;
Busbridge, Mark ;
Murphy, Kevin G. ;
Duncan, Neill D. ;
Cairns, Tom D. ;
Taube, David H. ;
Bloom, Stephen R. ;
Tam, Frederick W. K. ;
Chapman, Richard S. ;
Maxwell, Patrick H. ;
Choi, Peter .
KIDNEY INTERNATIONAL, 2009, 75 (09) :976-981
[4]   Quantification of hepcidin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Bansal, Sukhvinder S. ;
Halket, John M. ;
Fusova, Jane ;
Bomford, Adrian ;
Simpson, Robert J. ;
Vasavda, Nisha ;
Thein, Swee Lay ;
Hider, Robert C. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (11) :1531-1542
[5]   Quantitation of hepcidin in human urine by liquid chromatography-mass spectrometry [J].
Bansal, Sukhvinder S. ;
Halket, John M. ;
Bomford, Adrian ;
Simpson, Robert J. ;
Vasavda, Nisha ;
Thein, Swee Lay ;
Hider, Robert C. .
ANALYTICAL BIOCHEMISTRY, 2009, 384 (02) :245-253
[6]   Solvent/detergent treatment of human plasma -: A very robust method for virus inactivation.: Validated virus safety of OCTAPLAS® [J].
Blesert, L ;
Suhartono, H .
VOX SANGUINIS, 1998, 74 :207-212
[7]  
Bozzini C, 2002, CLIN CHEM, V48, P622
[8]   Robustness of solvent/detergent treatment of plasma derivatives: a data collection from Plasma Protein Therapeutics Association member companies [J].
Dichtelmueller, Herbert O. ;
Biesert, Lothar ;
Fabbrizzi, Fabrizio ;
Gajardo, Rodrigo ;
Groener, Albrecht ;
von Hoegen, Ilka ;
Jorquera, Juan I. ;
Kempf, Christoph ;
Kreil, Thomas R. ;
Pifat, Dominique ;
Osheroff, Wendy ;
Poelsler, Gerhard .
TRANSFUSION, 2009, 49 (09) :1931-1943
[9]   Hepcidin - a regulator of intestinal iron absorption and iron recycling by macrophages [J].
Ganz, T .
BEST PRACTICE & RESEARCH CLINICAL HAEMATOLOGY, 2005, 18 (02) :171-182
[10]   Immunoassay for human serum hepcidin [J].
Ganz, Tomas ;
Olbina, Gordana ;
Girelli, Domenico ;
Nemeth, Elizabeta ;
Westerman, Mark .
BLOOD, 2008, 112 (10) :4292-4297