Research on the Installation Lengths of Zero Block Concrete Segment in Prestressed Concrete Box-girder Beams with Corrugated Steel Webs

被引:0
作者
Zhao, Pin [1 ]
Ye, Jianshu [1 ]
机构
[1] Southeast Univ, Inst Bridge Engn, Nanjing 210096, Jiangsu, Peoples R China
来源
ADVANCES IN CIVIL ENGINEERING, PTS 1-6 | 2011年 / 255-260卷
关键词
prestressed concrete box-girder beams with corrugated steel webs; zero block of concrete segment; reasonable installation lengths; finite element analysis;
D O I
10.4028/www.scientific.net/AMR.255-260.1147
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
in order to study the reasonable installation lengths of zero block concrete segment in prestressed concrete box-girder beams with corrugated steel webs, a numerical analysis on the length of different zero blocks in PC box girder beams with corrugated steel webs is made by the finite element software ANSYS. The influence of the installation lengths of zero block concrete segment On the structure control section's internal forces and deformation is discussed. The results indicate: the impact of length changes of zero block on box girder deflection is greater than its impact on internal forces; in terms of deflection, the displacement influence in quarter-section in middle span is the largest; and in terms of internal forces, the internal forces influence of the junction section formed by zero block concrete segment and beam segment with corrugated steel webs is the largest. According to the above results and the relevant information of constructed bridges, the reasonable setting length of zero block concrete segment has been provided, that the ratio L-0/L of installation lengths and span for zero block of box girder should be in the range of 0.05 to 0.10.
引用
收藏
页码:1147 / 1153
页数:7
相关论文
共 6 条