A facile microdialysis interface for on-line desalting and identification of proteins by nano-electrospray ionization mass spectrometry

被引:21
作者
Sun, Liangliang [1 ,2 ]
Duan, Jicheng [1 ,2 ]
Tao, Dingyin [1 ,2 ]
Liang, Zhen [1 ,2 ]
Zhang, Weibing [1 ]
Zhang, Lihua [1 ]
Zhang, Yukui [1 ]
机构
[1] Chinese Acad Sci, Natl Chromatog Res & Anal Ctr, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
关键词
D O I
10.1002/rcm.3622
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The adverse effect of salts, especially inorganic salts, on electrospray ionization mass spectrometry (ESI-MS) is one of the most serious obstacles that might limit its application. Among the numerous desalting approaches, the microdialysis technique is favorable for large molecules, such as proteins. In this work, employing a hollow fiber membrane of cellulose acetate (MWCO 3000 Da), a simple, facile and efficient microdialysis interface with the dead volume of less than 1 mu L was constructed for the on-line desalting and identification of proteins dissolved in high salt concentration buffer by nano-ESI-MS. Furthermore, with counterflow added, the desalting procedure was accelerated, and could be finished within 1 min. This system was successfully applied to the analysis of myoglobin dissolved in either high concentration ammonium acetate or sodium chloride buffer. The experimental results showed that, by using such a microdialysis interface, the salt concentration, even as high as 1 M, could be decreased by at least 2 orders of magnitude, while sample loss was less than 10%, demonstrating the potential of such an interface in broadening the application of nano-ESI-MS in the analysis of large molecules. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:2391 / 2397
页数:7
相关论文
共 30 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P244, DOI 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO
[2]  
2-0
[3]   On-line microdialysis for enhanced resolution and sensitivity during electrospray mass spectrometry of non-covalent complexes and competitive binding studies [J].
Benkestock, K ;
Edlund, PO ;
Roeraade, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (21) :2054-2059
[4]   Microfluidic gradient formation for nanoflow chip LC [J].
Brennen, Reid A. ;
Yin, Hongfeng ;
Killeen, Kevin P. .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9302-9309
[5]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[6]   Optimizing TiO2-based phosphopeptide enrichment for automated multidimensional liquid chromatography coupled to tandem mass spectrometry [J].
Cantin, Greg T. ;
Shock, Teresa R. ;
Park, Sung Kyu ;
Madhani, Hiten D. ;
Yates, John R., III .
ANALYTICAL CHEMISTRY, 2007, 79 (12) :4666-4673
[7]   In-line desalting mass spectrometry for the study of noncovalent biological complexes [J].
Cavanagh, J ;
Benson, LM ;
Thompson, R ;
Naylor, S .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3281-3286
[8]   Integrated sample processing system involving on-column protein adsorption, sample washing, and enzyme digestion for protein identification by LC-ESI MS/MS [J].
Craft, D ;
Li, L .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2649-2655
[9]   Poly(dimethylsiloxane)-based microchip for two-dimensional solid-phase extraction-capillary electrophoresis with an integrated electrospray emitter tip [J].
Dahlin, AP ;
Bergström, SK ;
Andrén, PE ;
Markides, KE ;
Bergquist, J .
ANALYTICAL CHEMISTRY, 2005, 77 (16) :5356-5363
[10]   Rapid protein digestion and identification using monolithic enzymatic microreactor coupled with nano-liquid chromatography-electro spray ionization mass spectrometry [J].
Duan, JC ;
Sun, LL ;
Liang, Z ;
Zhang, J ;
Wang, H ;
Zhang, LH ;
Zhang, WB ;
Zhang, YK .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1106 (1-2) :165-174