Experimental Assessment of Lithium Hydride's Space Radiation Shielding Performance and Monte Carlo Benchmarking

被引:19
|
作者
Schuy, Christoph [1 ]
La Tessa, Chiara [2 ,3 ]
Horst, Felix [1 ,4 ]
Rovituso, Marta [2 ]
Durante, Marco [2 ,3 ]
Giraudo, Martina [5 ]
Bocchini, Luca [5 ,7 ]
Baricco, Marcello [6 ,8 ,9 ]
Castellero, Alberto [8 ,9 ]
Fiore, Gianluca [8 ,9 ]
Weber, Uli [1 ]
机构
[1] GSI Helmholtz Ctr Heavy Ion Res, Planckstr 1, D-64291 Darmstadt, Germany
[2] TIFPA, Povo, Italy
[3] Univ Trento, Dept Phys, Povo, Italy
[4] THM Univ Appl Sci Giessen, Inst Med Phys & Radiat Protect IMPS, Giessen, Germany
[5] Thales Alenia Space, Turin, Italy
[6] Politecn Torino, Dept Appl Sci & Technol, Turin, Italy
[7] Univ Torino, Dept Phys, Turin, Italy
[8] Univ Torino, Dept Chem, Turin, Italy
[9] Univ Torino, NIS, Turin, Italy
关键词
CARBON-ION THERAPY; PROTON; FRAGMENTATION; PROTECTION; WATER;
D O I
10.1667/RR15123.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The harmful effects of space radiation pose a serious health risk to astronauts participating in future long-term missions. Such radiation effects must be considered in the design phase of space vessels as well as in mission planning. Crew radioprotection during long periods in deep space (e.g., transit to Mars) represents a major challenge, especially because of the strong restrictions on the passive shielding load allowed on-board the vessel. Novel materials with better shielding performance compared to the "gold standard" high-density polyethylene are therefore greatly needed. Because of the high hydrogen content of hydrides, lithium hydride has been selected as a starting point for further studies of promising candidates to be used as passive shielding materials. In the current experimental campaign, the shielding performance of lithium hydride was assessed by measuring normalized dose, primary beam attenuation and neutron ambient dose equivalent using 430 MeV/u C-12, 600 MeV/u C-12 and 228 MeV proton beams. The experimental data were then compared to predictions from the Monte Carlo transport codes PHITS and GRAS. The experimental results show an increased shielding effectiveness of lithium hydride compared to reference materials like polyethylene. For instance, the attenuation length for 600 MeV/u C-12 primary particles in lithium hydride is approximately 20% shorter compared to polyethylene. Furthermore, the comparison results between both transport codes indicates that the standard Tripathi-based total reaction cross-section model of PHITS cannot accurately reproduce the presented experimental data, whereas GRAS shows reasonable agreement. (C) 2019 by Radiation Research Society
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [31] Monte Carlo phase space integration for initial state radiation
    Redouane-Salahand, E.
    Bauer, C. W.
    19TH INTERNATIONAL WORKSHOP ON ADVANCED COMPUTING AND ANALYSIS TECHNIQUES IN PHYSICS RESEARCH, 2020, 1525
  • [32] Monte Carlo track structure for radiation biology and space applications
    Nikjoo, H
    Uehara, S
    Khvostunov, IG
    Cucinotta, FA
    Wilson, WE
    Goodhead, DT
    PHYSICA MEDICA, 2001, 17 : 38 - 44
  • [33] Characterization of Ultramafic-Alkaline-Carbonatite complex for radiation shielding competencies: An experimental and Monte Carlo study with lithological mapping
    Libeesh, N. K.
    Naseer, K. A.
    Arivazhagan, S.
    Abd El-Rehim, A. F.
    ALMisned, Ghada
    Tekin, H. O.
    ORE GEOLOGY REVIEWS, 2022, 142
  • [34] Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector
    Nagata, Y.
    Kuroda, N.
    Kolbinger, B.
    Fleck, M.
    Malbrunot, C.
    Maeckel, V
    Sauerzopf, C.
    Simon, M. C.
    Tajima, M.
    Zmeskal, J.
    Breuker, H.
    Higaki, H.
    Kanai, Y.
    Matsuda, Y.
    Ulmer, S.
    Venturelli, L.
    Widmann, E.
    Yamazaki, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 910 : 90 - 95
  • [35] Assessment of neutron shielding performance of nano-TiO2-incorporated cement paste by Monte Carlo simulation
    Park, Jaeyeon
    Suh, Heongwon
    Woo, Seung Min
    Jeong, Keunhong
    Seok, Seungwook
    Bae, Sungchul
    PROGRESS IN NUCLEAR ENERGY, 2019, 117
  • [36] Implementation, capabilities, and benchmarking of Shift, a massively parallel Monte Carlo radiation transport code
    Pandya, Tara M.
    Johnson, Seth R.
    Evans, Thomas M.
    Davidson, GregoryG.
    Hamilton, Steven P.
    Godfrey, Andrew T.
    JOURNAL OF COMPUTATIONAL PHYSICS, 2016, 308 : 239 - 272
  • [37] IORT: Monte Carlo simulation of Mobetron accelerator and experimental comparison of shielding disk
    Toscano, L.
    Severgnini, M.
    Longo, F.
    Mario, D. D.
    Beorchia, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S987 - S988
  • [38] Space radiation transport, shielding, and risk assessment models
    Cucinotta, Francis A.
    Benton, Eugene V.
    RADIATION MEASUREMENTS, 2006, 41 (9-10) : 1051 - 1051
  • [39] Nuclear physics issues in space radiation risk assessment-the FLUKA Monte Carlo transport code used for space radiation measurement and protection
    Lee, K. T.
    VI Latin American Symposium on Nuclear Physics and Applications, 2007, 884 : 231 - 236
  • [40] Space neutron radiation shielding property of continuous fiber and functional filler reinforced polymer composite using Monte Carlo simulation
    Liu, Benben
    Gu, Yizhuo
    Liu, Yushun
    Wang, Shaokai
    Li, Min
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2023, 168