Experimental Assessment of Lithium Hydride's Space Radiation Shielding Performance and Monte Carlo Benchmarking

被引:19
|
作者
Schuy, Christoph [1 ]
La Tessa, Chiara [2 ,3 ]
Horst, Felix [1 ,4 ]
Rovituso, Marta [2 ]
Durante, Marco [2 ,3 ]
Giraudo, Martina [5 ]
Bocchini, Luca [5 ,7 ]
Baricco, Marcello [6 ,8 ,9 ]
Castellero, Alberto [8 ,9 ]
Fiore, Gianluca [8 ,9 ]
Weber, Uli [1 ]
机构
[1] GSI Helmholtz Ctr Heavy Ion Res, Planckstr 1, D-64291 Darmstadt, Germany
[2] TIFPA, Povo, Italy
[3] Univ Trento, Dept Phys, Povo, Italy
[4] THM Univ Appl Sci Giessen, Inst Med Phys & Radiat Protect IMPS, Giessen, Germany
[5] Thales Alenia Space, Turin, Italy
[6] Politecn Torino, Dept Appl Sci & Technol, Turin, Italy
[7] Univ Torino, Dept Phys, Turin, Italy
[8] Univ Torino, Dept Chem, Turin, Italy
[9] Univ Torino, NIS, Turin, Italy
关键词
CARBON-ION THERAPY; PROTON; FRAGMENTATION; PROTECTION; WATER;
D O I
10.1667/RR15123.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The harmful effects of space radiation pose a serious health risk to astronauts participating in future long-term missions. Such radiation effects must be considered in the design phase of space vessels as well as in mission planning. Crew radioprotection during long periods in deep space (e.g., transit to Mars) represents a major challenge, especially because of the strong restrictions on the passive shielding load allowed on-board the vessel. Novel materials with better shielding performance compared to the "gold standard" high-density polyethylene are therefore greatly needed. Because of the high hydrogen content of hydrides, lithium hydride has been selected as a starting point for further studies of promising candidates to be used as passive shielding materials. In the current experimental campaign, the shielding performance of lithium hydride was assessed by measuring normalized dose, primary beam attenuation and neutron ambient dose equivalent using 430 MeV/u C-12, 600 MeV/u C-12 and 228 MeV proton beams. The experimental data were then compared to predictions from the Monte Carlo transport codes PHITS and GRAS. The experimental results show an increased shielding effectiveness of lithium hydride compared to reference materials like polyethylene. For instance, the attenuation length for 600 MeV/u C-12 primary particles in lithium hydride is approximately 20% shorter compared to polyethylene. Furthermore, the comparison results between both transport codes indicates that the standard Tripathi-based total reaction cross-section model of PHITS cannot accurately reproduce the presented experimental data, whereas GRAS shows reasonable agreement. (C) 2019 by Radiation Research Society
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [1] MULASSIS - Monte Carlo radiation shielding simulation for space applications made easy
    Truscott, P
    Lei, F
    Dyer, C
    Quaghebeur, B
    Heyndericks, D
    Nieminen, P
    Evans, H
    Daly, E
    Mohammadzadeh, A
    Hopkinson, G
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2004, 536 : 191 - 196
  • [2] LITHIUM HYDRIDE - SPACE AGE SHIELDING MATERIAL
    WELCH, FH
    NUCLEAR ENGINEERING AND DESIGN, 1974, 26 (03) : 444 - 460
  • [3] Structural and nuclear radiation shielding properties of bauxite ore doped lithium borate glasses: Experimental and Monte Carlo study
    Kavaz, E.
    Tekin, H. O.
    Yorgun, N. Yildiz
    Ozdemir, O. F.
    Sayyed, M. I.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 162 : 187 - 193
  • [4] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Da-Eun Kwon
    Dong-Hee Han
    Kyung-Hwan Jung
    Seung-Jae Lee
    Jang-Oh Kim
    Cheol-Ha Baek
    Journal of the Korean Physical Society, 2023, 82 : 813 - 817
  • [5] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Kwon, Da-Eun
    Han, Dong-Hee
    Jung, Kyung-Hwan
    Lee, Seung-Jae
    Kim, Jang-Oh
    Baek, Cheol-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 82 (08) : 813 - 817
  • [6] Application of The Monte Carlo Simulation Method to Simulate the Radiation Shielding Capacity of Lithium Tungstate Composites
    Mahmoud, K. A.
    Tashlykov, O. L.
    VII INTERNATIONAL YOUNG RESEARCHERS' CONFERENCE - PHYSICS, TECHNOLOGY, INNOVATIONS (PTI-2020), 2020, 2313
  • [7] Geant4 - A new Monte Carlo toolkit for simulating space radiation shielding and effects
    Truscott, P
    Lei, F
    Dyer, C
    Ferguson, C
    Gurriaran, R
    Nieminen, P
    Daly, E
    Apostolakis, J
    Giani, S
    Pia, MG
    Urban, L
    Maire, M
    2000 IEEE RADIATION EFFECTS DATA WORKSHOP - WORKSHOP RECORD, 2000, : 147 - 152
  • [8] SPACE REACTOR SHIELDING - LITHIUM-HYDRIDE LABORATORY STUDIES
    WELCH, FH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 139 - &
  • [9] Monte Carlo Simulation of radiation effects in space
    Wang, Tongquan
    Shen, Yongping
    Zhang, Ruoqi
    Wang, Shangwu
    Zhang, Shufa
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2000, 12 (03): : 339 - 342
  • [10] Borax effect on gamma and neutron shielding features of lithium borate glasses: an experimental and Monte Carlo studies
    Yorgun, N. Yildiz
    Kavaz, E.
    Tekin, H. O.
    Sayyed, M., I
    Ozdemir, O. F.
    MATERIALS RESEARCH EXPRESS, 2019, 6 (11)