Binding Studies of Cationic Conjugated Polymers and DNA for Label-Free Fluorescent Biosensors

被引:10
|
作者
Zhang, Pengbo [1 ]
Lu, Chang [2 ]
Niu, Chenqi [2 ]
Wang, Xiaoyu [3 ]
Li, Zhengping [1 ]
Liu, Juewen [2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Chem & Biol Engn, Beijing 100083, Peoples R China
[2] Univ Waterloo, Waterloo Inst Nanotechnol, Dept Chem, Waterloo, ON N2L 3G1, Canada
[3] Univ Sci & Technol Beijing, Sch Mat Sci & Engn, Beijing 100083, Peoples R China
来源
ACS APPLIED POLYMER MATERIALS | 2022年 / 4卷 / 08期
基金
加拿大自然科学与工程研究理事会;
关键词
cationic conjugated polymers; DNA detection; biosensors; aptamers; fluorescence; OPTICAL-DETECTION; METHYLATION; PHOTOPHYSICS; MERCURY(II); PROBE;
D O I
10.1021/acsapm.2c00986
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cationic conjugated polymers (CCPs), especially polythiophene, have been extensively used as probes for developing DNA and aptamer-based biosensors. Although many interesting applications have been achieved, a fundamental understanding of this system remains quite limited. In this work, we performed systematic binding assays to understand the interactions between poly(3-(3 & PRIME;- N,N,N-triethylamino-1 & PRIME;-propyloxy) -4-methyl-2, 5-thiop hene ) (PMNT) and DNA. The fluorescence of PMNT at 530 nm initially decreased and then a peak at 580 nm emerged after binding with single-stranded DNA (ssDNA). The binding force between PMNT and DNA was dominated by electrostatic interactions at first and then DNA base-mediated interactions also became important. Since the bases in double-stranded DNA (dsDNA) were shielded, their fluorescence changes were quite different. To best differentiate ssDNA and dsDNA, the optimal pH was between 6 and 8, and the optimal NaCl concentration was around 0.3 M. Moreover, by changing the sequence and length of ssDNA, poly-T had the largest fluorescence shift and poly-A had the smallest change. Under the optimized conditions, the PMNT-based biosensor had a detection limit of 1 nM DNA, which was similar to the SYBR Green I-based assay.
引用
收藏
页码:6211 / 6218
页数:8
相关论文
共 50 条
  • [21] Asymmetric Concentric Microring Resonator Label-Free Biosensors
    Chamorro-Posada, Pedro
    PHOTONICS, 2022, 9 (01)
  • [22] Biosensors with label-free detection designed for diagnostic applications
    Bastian E. Rapp
    Friederike J. Gruhl
    Kerstin Länge
    Analytical and Bioanalytical Chemistry, 2010, 398 : 2403 - 2412
  • [23] A Label-Free Fluorescent DNA Machine for Sensitive Cyclic Amplification Detection of ATP
    Zhang, Jingjing
    Han, Jialun
    Feng, Shehong
    Niu, Chaoqun
    Liu, Chen
    Du, Jie
    Chen, Yong
    MATERIALS, 2018, 11 (12)
  • [24] Water-soluble fluorescent conjugated polymers and their interactions with biomacromolecules for sensitive biosensors
    Feng, Xuli
    Liu, Libing
    Wang, Shu
    Zhu, Daoben
    CHEMICAL SOCIETY REVIEWS, 2010, 39 (07) : 2411 - 2419
  • [25] Label-Free Fluorescent Functional DNA Sensors Using Unmodified DNA: A Vacant Site Approach
    Xiang, Yu
    Wang, Zidong
    Xing, Hang
    Wong, Ngo Yin
    Lu, Yi
    ANALYTICAL CHEMISTRY, 2010, 82 (10) : 4122 - 4129
  • [26] Cationic-perylene-G-quadruplex complex based fluorescent biosensor for label-free detection of Pb2+
    Zhao, Xu-Hua
    Gong, Liang
    Wu, Yuan
    Zhang, Xiao-Bing
    Xie, Jun
    TALANTA, 2016, 149 : 98 - 102
  • [27] Label-Free Multiplex DNA Detection Utilizing Projected Capacitive Touchscreen
    Lee, Joon Young
    Won, Byoung Yeon
    Park, Hyun Gyu
    BIOTECHNOLOGY JOURNAL, 2018, 13 (02)
  • [28] A label-free and signal-on supersandwich fluorescent platform for Hg2+ sensing
    Yuan, Tao
    Hu, Lianzhe
    Liu, Zhongyuan
    Qi, Wenjing
    Zhu, Shuyun
    Aziz-ur-Rehman
    Xu, Guobao
    ANALYTICA CHIMICA ACTA, 2013, 793 : 86 - 89
  • [29] Conjugated Polymer Nanoparticles for Label-Free and Bioconjugate-Recognized DNA Sensing in Serum
    Bao, Biqing
    Ma, Mingfeng
    Zai, Huafeng
    Zhang, Lei
    Fu, Nina
    Huang, Wei
    Wang, Lianhui
    ADVANCED SCIENCE, 2015, 2 (03)
  • [30] Optical Fiber Sensors for Label-Free DNA Detection
    Barozzi, Matteo
    Manicardi, Alex
    Vannucci, Armando
    Candiani, Alessandro
    Sozzi, Michele
    Konstantaki, Maria
    Pissadakis, Stavros
    Corradini, Roberto
    Selleri, Stefano
    Cucinotta, Annamaria
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2017, 35 (16) : 3461 - 3472