Quantitative Mapping of Tumor Vascularity Using Volumetric Contrast-Enhanced Ultrasound

被引:80
|
作者
Hoyt, Kenneth [1 ,2 ,3 ]
Sorace, Anna [2 ]
Saini, Reshu [2 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Ctr Comprehens Canc, Birmingham, AL 35294 USA
关键词
contrast agent; microbubbles; perfusion imaging; volumetric ultrasound imaging; BLOOD-FLOW; ANGIOGENESIS; BREAST; MODEL; US; MICROCIRCULATION; THERAPY;
D O I
10.1097/RLI.0b013e318234e6bc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal of this research project was to develop a volumetric strategy for real-time monitoring and characterization of tumor blood flow using microbubble contrast agents and ultrasound (US) imaging. Materials and Methods: Volumetric contrast-enhanced US (VCEUS) imaging was implemented on a SONIX RP US system (Ultrasonix Medical Corp, Richmond, BC) equipped with a broadband 4DL14-5/38 probe. Using a microbubble-sensitive harmonic imaging mode (transducer transmits at 5 MHz and receives at 10 MHz), acquisition of postscan-converted VCEUS data was achieved at a volume rate of 1 Hz. After microbubble infusion, custom data processing software was used to derive microbubble time-intensity curve-specific parameters, namely, blood volume (I PK), transit time (T1/2PK), flow rate (S PK), and tumor perfusion (AUC). Results: Using a preclinical breast cancer animal model, it is shown that millimeter-sized deviations in transducer positioning can have profound implications on US-based blood flow estimators, with errors ranging from 6.4% to 40.3% and dependent on both degree of misalignment (offset) and particular blood flow estimator. These errors indicate that VCEUS imaging should be considered in tumor analyses, because they incorporate the entire mass and not just a representative planar cross-section. After administration of an antiangiogenic therapeutic drug (bevacizumab), tumor growth was significantly retarded compared with control tumors (P > 0.03) and reflects observed changes in VCEUS-based blood flow measurements. Analysis of immunohistologic data revealed no differences in intratumoral necrosis levels (P = 0.70), but a significant difference was found when comparing microvessel density counts in control with therapy group tumors (P = 0.05). Conclusions: VCEUS imaging was shown to be a promising modality for monitoring changes in tumor blood flow. Preliminary experimental results are encouraging, and this imaging modality may prove clinically feasible for detecting and monitoring the early antitumor effects in response to cancer drug therapy.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [41] SPLANCHNIC HEMODYNAMICS AND INTESTINAL VASCULARITY IN CROHN'S DISEASE: AN IN VIVO EVALUATION USING DOPPLER AND CONTRAST-ENHANCED ULTRASOUND AND BIOCHEMICAL PARAMETERS
    Maconi, Giovanni
    Asthana, Anil K.
    Bolzacchini, Elena
    Dell'Era, Alessandra
    Furfaro, Federica
    Bezzio, Cristina
    Salvatore, Veronica
    Maier, Jeanette A. M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (01) : 150 - 158
  • [42] Quantitative dynamic contrast-enhanced ultrasound for the functional evaluation of the skeletal muscle microcirculation in systemic sclerosis
    Partovi, Sasan
    Kaspar, Mathias
    Aschwanden, Markus
    Robbin, Mark R.
    Bilecen, Deniz
    Walker, Ulrich A.
    Staub, Daniel
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 62 (01) : 35 - 44
  • [43] Evaluation of finger joint synovial vascularity in patients with rheumatoid arthritis using contrast-enhanced ultrasound with water immersion and a stabilized probe
    Stramare, Roberto
    Raffeiner, Bernd
    Ciprian, Luca
    Scagliori, Elena
    Coran, Alessandro
    Perissinotto, Egle
    Fiocco, Ugo
    Beltrame, Valeria
    Rubaltelli, Leopoldo
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (03) : 147 - 154
  • [44] Reducing tumor growth and angiogenesis using a triple therapy measured with Contrast-enhanced ultrasound (CEUS)
    Paprottka, Philipp Marius
    Rosspunt, Svenja
    Ingrisch, Michael
    Cyran, Clemens C.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Mack, Brigitte
    Gires, Olivier
    Clevert, Dirk A.
    Zengel, Pamela
    BMC CANCER, 2015, 15 : 1
  • [45] Contrast-enhanced ultrasound for guidance of local tumor ablation
    Brown, JM
    Chaloupka, J
    Taylor, KJW
    Quedens-Case, C
    Alderman, J
    Greener, Y
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08) : 1213 - 1219
  • [46] Contrast-enhanced ultrasound of skeletal muscle
    Weber, M. -A.
    Wormsbecher, S.
    Krix, M.
    RADIOLOGE, 2011, 51 (06): : 497 - 505
  • [47] Intravascular Targets for Molecular Contrast-Enhanced Ultrasound Imaging
    Moestue, Siver A.
    Gribbestad, Ingrid S.
    Hansen, Rune
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2012, 13 (06): : 6679 - 6697
  • [48] Analysis of early response to chemotherapy for non-Hodgkin's lymphoma by quantitative contrast-enhanced ultrasound: A prospective case-control crossectional study
    Lu, Wenjuan
    Deng, Hongyan
    Chen, Wenqin
    Zhou, Yasu
    Wu, Liuxi
    Shu, Hua
    Zhang, Pingyang
    Ye, Xinhua
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 176
  • [49] Tumor vascularity: Evaluation in a murine model with contrast-enhanced color Doppler US - Effect of angiogenesis inhibitors
    Iordanescu, I
    Becker, C
    Zetter, B
    Dunning, P
    Taylor, GA
    RADIOLOGY, 2002, 222 (02) : 460 - 467
  • [50] A Comprehensive and Repeatable Contrast-Enhanced Ultrasound Quantification Approach for Clinical Evaluations of Tumor Blood Flow
    Krolak, Connor
    Wei, Angela
    Shumaker, Marissa
    Dighe, Manjiri
    Averkiou, Michalakis
    INVESTIGATIVE RADIOLOGY, 2025, 60 (04) : 281 - 290