Quantitative Mapping of Tumor Vascularity Using Volumetric Contrast-Enhanced Ultrasound

被引:80
|
作者
Hoyt, Kenneth [1 ,2 ,3 ]
Sorace, Anna [2 ]
Saini, Reshu [2 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Ctr Comprehens Canc, Birmingham, AL 35294 USA
关键词
contrast agent; microbubbles; perfusion imaging; volumetric ultrasound imaging; BLOOD-FLOW; ANGIOGENESIS; BREAST; MODEL; US; MICROCIRCULATION; THERAPY;
D O I
10.1097/RLI.0b013e318234e6bc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal of this research project was to develop a volumetric strategy for real-time monitoring and characterization of tumor blood flow using microbubble contrast agents and ultrasound (US) imaging. Materials and Methods: Volumetric contrast-enhanced US (VCEUS) imaging was implemented on a SONIX RP US system (Ultrasonix Medical Corp, Richmond, BC) equipped with a broadband 4DL14-5/38 probe. Using a microbubble-sensitive harmonic imaging mode (transducer transmits at 5 MHz and receives at 10 MHz), acquisition of postscan-converted VCEUS data was achieved at a volume rate of 1 Hz. After microbubble infusion, custom data processing software was used to derive microbubble time-intensity curve-specific parameters, namely, blood volume (I PK), transit time (T1/2PK), flow rate (S PK), and tumor perfusion (AUC). Results: Using a preclinical breast cancer animal model, it is shown that millimeter-sized deviations in transducer positioning can have profound implications on US-based blood flow estimators, with errors ranging from 6.4% to 40.3% and dependent on both degree of misalignment (offset) and particular blood flow estimator. These errors indicate that VCEUS imaging should be considered in tumor analyses, because they incorporate the entire mass and not just a representative planar cross-section. After administration of an antiangiogenic therapeutic drug (bevacizumab), tumor growth was significantly retarded compared with control tumors (P > 0.03) and reflects observed changes in VCEUS-based blood flow measurements. Analysis of immunohistologic data revealed no differences in intratumoral necrosis levels (P = 0.70), but a significant difference was found when comparing microvessel density counts in control with therapy group tumors (P = 0.05). Conclusions: VCEUS imaging was shown to be a promising modality for monitoring changes in tumor blood flow. Preliminary experimental results are encouraging, and this imaging modality may prove clinically feasible for detecting and monitoring the early antitumor effects in response to cancer drug therapy.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [31] Assessing tumor angiogenesis in colorectal cancer by quantitative contrast-enhanced endoscopic ultrasound and molecular and immunohistochemical analysis
    Cartana, Elena-Tatiana
    Gheonea, Dan Ionut
    Cherciu, Irina Florina
    Streata, Ioana
    Uscatu, Constantin-Daniel
    Nicoli, Elena-Raluca
    Ioana, Mihai
    Pirici, Daniel
    Georgescu, Claudia-Valentina
    Alexandru, Dragos-Ovidiu
    Surlin, Valeriu
    Gruionu, Gabriel
    Saftoiu, Adrian
    ENDOSCOPIC ULTRASOUND, 2018, 7 (03) : 175 - 183
  • [32] Development of a Fluid Dynamic Model for Quantitative Contrast-Enhanced Ultrasound Imaging
    de Senneville, Baudouin Denis
    Novell, Anthony
    Arthuis, Chloe
    Mendes, Vanda
    Dujardin, Paul-Armand
    Patat, Frederic
    Bouakaz, Ayache
    Escoffre, Jean-Michel
    Perrotin, Franck
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (02) : 372 - 383
  • [33] Contrast-Enhanced Gray-Scale Ultrasound for Quantitative Evaluation of Tumor Response to Chemotherapy: Preliminary Results With a Mouse Hepatoma Model
    Zhou, Jian-Hua
    Cao, Long-Hui
    Zheng, Wei
    Liu, Min
    Han, Feng
    Li, An-Hua
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (01) : 13 - 17
  • [34] Correlation of Quantified Contrast-Enhanced Sonography With In Vivo Tumor Response
    Hwang, Misun
    Hariri, Ghazal
    Lyshchik, Andrej
    Hallahan, Dennis E.
    Fleischer, Arthur C.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (04) : 597 - 607
  • [35] Contrast-enhanced Ultrasound Imaging of Antiangiogenic Tumor Therapy
    Klotz, Laura V.
    Clevert, Dirk-Andre
    Scheckinger, Siiri
    Strieth, Sebastian
    Eichhorn, Martin E.
    ANTICANCER RESEARCH, 2015, 35 (05) : 2571 - 2576
  • [36] Contrast-Enhanced Ultrasound
    Hunt, David
    Romero, Javier
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (04) : 725 - +
  • [37] Brain tumor classification on intraoperative contrast-enhanced ultrasound
    Ritschel, Kai
    Pechlivanis, Ioannis
    Winter, Susanne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (05) : 531 - 540
  • [38] Baseline and Contrast-Enhanced Ultrasound of the Liver in Tumor Patients
    Oldenburg, A.
    Albrecht, T.
    ULTRASCHALL IN DER MEDIZIN, 2008, 29 (05): : 488 - 498
  • [39] LONGITUDINAL CHANGES IN KNEE JOINT SYNOVIAL VASCULARITY IN A RABBIT MODEL OF RHEUMATOID ARTHRITIS: QUANTIFICATION USING POWER DOPPLER ULTRASOUND AND CONTRAST-ENHANCED ULTRASOUND
    Liu, Hui
    Chen, Shuqiang
    Huang, Chao
    Zheng, Qing
    Ye, Yuhong
    Ye, Zhen
    Lyu, Guorong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (08) : 2430 - 2441
  • [40] Brain tumor classification on intraoperative contrast-enhanced ultrasound
    Kai Ritschel
    Ioannis Pechlivanis
    Susanne Winter
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 531 - 540