Quantitative Mapping of Tumor Vascularity Using Volumetric Contrast-Enhanced Ultrasound

被引:80
|
作者
Hoyt, Kenneth [1 ,2 ,3 ]
Sorace, Anna [2 ]
Saini, Reshu [2 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Ctr Comprehens Canc, Birmingham, AL 35294 USA
关键词
contrast agent; microbubbles; perfusion imaging; volumetric ultrasound imaging; BLOOD-FLOW; ANGIOGENESIS; BREAST; MODEL; US; MICROCIRCULATION; THERAPY;
D O I
10.1097/RLI.0b013e318234e6bc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal of this research project was to develop a volumetric strategy for real-time monitoring and characterization of tumor blood flow using microbubble contrast agents and ultrasound (US) imaging. Materials and Methods: Volumetric contrast-enhanced US (VCEUS) imaging was implemented on a SONIX RP US system (Ultrasonix Medical Corp, Richmond, BC) equipped with a broadband 4DL14-5/38 probe. Using a microbubble-sensitive harmonic imaging mode (transducer transmits at 5 MHz and receives at 10 MHz), acquisition of postscan-converted VCEUS data was achieved at a volume rate of 1 Hz. After microbubble infusion, custom data processing software was used to derive microbubble time-intensity curve-specific parameters, namely, blood volume (I PK), transit time (T1/2PK), flow rate (S PK), and tumor perfusion (AUC). Results: Using a preclinical breast cancer animal model, it is shown that millimeter-sized deviations in transducer positioning can have profound implications on US-based blood flow estimators, with errors ranging from 6.4% to 40.3% and dependent on both degree of misalignment (offset) and particular blood flow estimator. These errors indicate that VCEUS imaging should be considered in tumor analyses, because they incorporate the entire mass and not just a representative planar cross-section. After administration of an antiangiogenic therapeutic drug (bevacizumab), tumor growth was significantly retarded compared with control tumors (P > 0.03) and reflects observed changes in VCEUS-based blood flow measurements. Analysis of immunohistologic data revealed no differences in intratumoral necrosis levels (P = 0.70), but a significant difference was found when comparing microvessel density counts in control with therapy group tumors (P = 0.05). Conclusions: VCEUS imaging was shown to be a promising modality for monitoring changes in tumor blood flow. Preliminary experimental results are encouraging, and this imaging modality may prove clinically feasible for detecting and monitoring the early antitumor effects in response to cancer drug therapy.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [1] Assessment and Monitoring Tumor Vascularity With Contrast-Enhanced Ultrasound Maximum Intensity Persistence Imaging
    Pysz, Marybeth A.
    Foygel, Kira
    Panje, Cedric M.
    Needles, Andrew
    Tian, Lu
    Willmann, Juergen K.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (03) : 187 - 195
  • [2] Volumetric Contrast-Enhanced Ultrasound for Characterizing Tumor Vascularity: Preliminary Studies in an Animal Model
    Hoyt, Kenneth
    Sorace, Anna G.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1292 - 1295
  • [3] Tumor Perfusion and Neovascular Morphology Measurements using Dynamic Contrast-Enhanced Ultrasound Imaging
    Hoyt, Kenneth
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 197 - 200
  • [4] Assessment of tumour angiogenesis using Contrast-Enhanced Ultrasound
    Cosgrove, D.
    Lassau, N.
    JOURNAL DE RADIOLOGIE, 2009, 90 (01): : 156 - 164
  • [5] Up-to-date Doppler techniques for breast tumor vascularity: superb microvascular imaging and contrast-enhanced ultrasound
    Park, Ah Young
    Seo, Bo Kyoung
    ULTRASONOGRAPHY, 2018, 37 (02) : 98 - 106
  • [6] Quantitative evaluation of microvascular blood flow by contrast-enhanced ultrasound (CEUS)
    Greis, Christian
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) : 137 - 149
  • [7] Volumetric Contrast-Enhanced Ultrasound Imaging of Renal Perfusion
    Mahoney, Marshall
    Sorace, Anna
    Warram, Jason
    Samuel, Sharon
    Hoyt, Kenneth
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (08) : 1427 - 1437
  • [8] Quantitative Volumetric Perfusion Mapping of the Microvasculature Using Contrast Ultrasound
    Feingold, Steven
    Gessner, Ryan
    Guracar, Ismayil M.
    Dayton, Paul A.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (10) : 669 - 674
  • [9] Quantitative Nonlinear Contrast-Enhanced Ultrasound of the Breast
    Sridharan, Anush
    Eisenbrey, John R.
    Dave, Jaydev K.
    Forsberg, Flemming
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (02) : 274 - 281
  • [10] VALIDATION OF DYNAMIC CONTRAST-ENHANCED ULTRASOUND IN RODENT KIDNEYS AS AN ABSOLUTE QUANTITATIVE METHOD FOR MEASURING BLOOD PERFUSION
    Kogan, Paul
    Johnson, Kennita A.
    Feingold, Steven
    Garrett, Nicholas
    Guracar, Ismayil
    Arendshorst, William J.
    Dayton, Paul A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (06) : 900 - 908