Integrated readout electronics:: Enabling advanced applications of position-sensitive solid-state radiation detectors

被引:0
|
作者
Cajipe, VB [1 ]
Calderwood, RF [1 ]
Clajus, M [1 ]
Hayakawa, S [1 ]
Tümer, TO [1 ]
Yin, S [1 ]
机构
[1] NOVA R&D Inc, Riverside, CA 92507 USA
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
As applications of advanced solid-state radiation detector arrays proliferate across disciplines ranging from x-ray astronomy and medical imaging to security and industrial inspection, the relative scarcity of low-noise, multi-channel integrated circuits (ICs) needed to read out these arrays has become increasingly apparent. In fact, readout ICs are now regarded to be an integral part of position-sensitive semiconductor detectors for x-ray and gamma-ray imaging. Because the requirements of various detector applications tend to be diverse, a custom IC is typically designed for a specific detector array. This often lengthens the time and raises the cost of system development. To help close the readout technology gap and facilitate advances in this field, NOVA has been formulating strategies for instrumenting different detectors of a given application category with the same "generic" IC which embodies common functions as well as selectable features. A brief overview of possible approaches to such generic ICs will be given. Within this context, accomplishments and ongoing efforts at NOVA in developing front-end ICs for various detector architectures and signal-processing scenarios will be described. We will especially consider the case of ICs used in conjunction with position sensitive CZT detectors, implemented in traditional soldered lead or flip-chip connection geometries, to perform spectroscopic, energy-binning or current-mode type measurements.
引用
收藏
页码:4342 / 4346
页数:5
相关论文
共 50 条
  • [41] Novel position-sensitive gaseous detectors with solid photo-cathodes
    Francke, T
    Peskov, V
    Rodionov, I
    Sokolova, T
    Sharma, A
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 945 - 950
  • [42] POSITION SENSITIVE SOLID STATE DETECTORS.
    Schnatterly, S.E.
    Husk, D.
    Nuclear instruments and methods in physics research, 1985, A246 (1-3): : 517 - 522
  • [43] Charge-coupled instruments as position-sensitive detectors of X radiation
    Inst Innovatsionnykh i, Termoyadernykh Issledovanij, Troitsk, Russia
    Prib Tekh Eksp, 3 (119-127):
  • [44] Position-sensitive radiation detectors made of single crystal CVD diamond
    Pomorski, M.
    Ciobanu, M.
    Mer, C.
    Rebisz-Pomorska, M.
    Tromson, D.
    Bergonzo, R.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2009, 206 (09): : 2109 - 2114
  • [45] Position-sensitive detectors of nuclear radiation and a study of their current−voltage characteristic
    Yo. K. Toshmurodov
    Instruments and Experimental Techniques, 2017, 60 : 605 - 607
  • [46] Radiation hard position-sensitive cryogenic silicon detectors:: the Lazarus effect
    Palmieri, VG
    Abreu, MC
    Bell, WH
    Berglund, P
    de Boer, W
    Borchi, E
    Borer, K
    Bruzzi, M
    Buontempo, S
    Casagrande, L
    Chapuy, S
    Cindro, V
    D'Ambrosio, N
    Da Viá, C
    Devine, S
    Dezillie, B
    Dimcovski, Z
    Eremin, V
    Esposito, A
    Granata, V
    Grigoriev, E
    Hauler, F
    Heijne, E
    Heising, S
    Janos, S
    Jungermann, L
    Konorov, I
    Li, Z
    Lourenço, C
    Mikuz, M
    Niinikoski, TO
    O'Shea, V
    Pagano, S
    Paul, S
    Pirollo, S
    Pretzl, K
    Rato, P
    Ruggiero, G
    Smith, K
    Sonderegger, P
    Sousa, P
    Verbitskaya, E
    Watts, S
    Zavrtanik, M
    PHYSICA B-CONDENSED MATTER, 2000, 280 (1-4) : 532 - 534
  • [47] HODOSCOPE READOUT SYSTEM AND OPTICAL BINARY CODED POSITION-SENSITIVE RADIATION DETECTOR
    LEE, LY
    ALLRED, JC
    GOODMAN, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 719 - 719
  • [48] Advanced data readout technique for Multianode Position Sensitive Photomultiplier Tube applicable in radiation imaging detectors
    Popov, V.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [49] A Low-power Continuous- Reset CMOS Charge-Sensitive Amplifier for the Readout of Solid-State Radiation Detectors
    Beikahmadi, Mohammad
    Iniewski, Krzysztof
    Mirabbasi, Shahriar
    2016 14TH IEEE INTERNATIONAL NEW CIRCUITS AND SYSTEMS CONFERENCE (NEWCAS), 2016,
  • [50] OPTICAL DEFLECTOR WITH POSITION READOUT AND SOLID-STATE DRIVE
    SCHLAFER, J
    REICH, S
    FOWLER, V
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1969, QE 5 (06) : 351 - &