Integrated readout electronics:: Enabling advanced applications of position-sensitive solid-state radiation detectors

被引:0
|
作者
Cajipe, VB [1 ]
Calderwood, RF [1 ]
Clajus, M [1 ]
Hayakawa, S [1 ]
Tümer, TO [1 ]
Yin, S [1 ]
机构
[1] NOVA R&D Inc, Riverside, CA 92507 USA
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
As applications of advanced solid-state radiation detector arrays proliferate across disciplines ranging from x-ray astronomy and medical imaging to security and industrial inspection, the relative scarcity of low-noise, multi-channel integrated circuits (ICs) needed to read out these arrays has become increasingly apparent. In fact, readout ICs are now regarded to be an integral part of position-sensitive semiconductor detectors for x-ray and gamma-ray imaging. Because the requirements of various detector applications tend to be diverse, a custom IC is typically designed for a specific detector array. This often lengthens the time and raises the cost of system development. To help close the readout technology gap and facilitate advances in this field, NOVA has been formulating strategies for instrumenting different detectors of a given application category with the same "generic" IC which embodies common functions as well as selectable features. A brief overview of possible approaches to such generic ICs will be given. Within this context, accomplishments and ongoing efforts at NOVA in developing front-end ICs for various detector architectures and signal-processing scenarios will be described. We will especially consider the case of ICs used in conjunction with position sensitive CZT detectors, implemented in traditional soldered lead or flip-chip connection geometries, to perform spectroscopic, energy-binning or current-mode type measurements.
引用
收藏
页码:4342 / 4346
页数:5
相关论文
共 50 条
  • [1] POSITION-SENSITIVE SOLID-STATE DETECTORS
    SCHNATTERLY, SE
    HUSK, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 517 - 522
  • [2] Test results of the readout electronics for nuclear applications (RENA) chip developed for position-sensitive solid state detectors
    Kravis, SD
    Tümer, TO
    Visser, GJ
    Maeding, DG
    Yin, S
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 374 - 382
  • [3] Development and applications of position-sensitive solid-state gamma ray detectors
    Kurfess, JD
    Johnson, WN
    Kroeger, RA
    Phlips, BF
    Wulf, EA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 256 - 264
  • [4] An advanced Compton telescope based on thick, position-sensitive solid-state detectors
    Kurfess, JD
    Johnson, WN
    Kroeger, RA
    Novikova, EI
    Phlips, BF
    Strickman, MS
    Wulf, EA
    NEW ASTRONOMY REVIEWS, 2004, 48 (1-4) : 293 - 298
  • [5] Readout electronics for position-sensitive gas filled detectors at the European Synchrotron Radiation Facility
    Hervé, C
    Le Caër, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 226 - 231
  • [6] New readout integrated circuits for position sensitive solid state detectors
    Tümer, TO
    Cajipe, VB
    Calderwood, RF
    Clajus, M
    Hayakawa, S
    Yin, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1436 - 1439
  • [7] POSITION DETERMINATION AND RESOLUTION OF 2-DIMENSIONAL POSITION-SENSITIVE SOLID-STATE DETECTORS
    BRUNO, M
    DAGOSTINO, M
    FIANDRI, ML
    FUSCHINI, E
    MILAZZO, PM
    OSTUNI, S
    GRAMEGNA, F
    IORI, I
    MANDUCI, L
    MORONI, A
    SCARDAONI, R
    BUTTAZZO, P
    MARGAGLIOTTI, GV
    VANNINI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (1-2): : 189 - 194
  • [8] A front end readout electronics ASIC chip for position sensitive solid state detectors
    Kravis, SD
    Tumer, TO
    Visser, GJ
    Maeding, DG
    Yin, S
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 579 - 584
  • [9] Performance of RENA-3 IC with Position-Sensitive Solid-State Detectors
    Turner, Tumay O.
    Cajipe, Victoria B.
    Clajus, Martin
    Hayakawa, Satoshi
    Volkovskii, Alexander
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
  • [10] Alpha-particle spectrometry using position-sensitive solid-state track detectors
    Dyachkov, V. V.
    Yushkov, A. V.
    Shakirov, A. L.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2013, 56 (05) : 521 - 524