Will naturally ventilated dwellings remain safe during heatwaves?

被引:15
作者
Alessandrini, Jean-Marie [1 ]
Riberon, Jacques [2 ]
Da Silva, David [1 ]
机构
[1] CSTB, Environm & Energy Dept, 84 Ave Jean Jaures, F-77447 Champs Sur Marne, Marne La Vallee, France
[2] CSTB, Hlth & Comfort Dept, 84 Ave Jean Jaures, F-77447 Champs Sur Marne, Marne La Vallee, France
关键词
Thermal comfort; Heat stress; Natural ventilative cooling; Health; Climate change; HEAT-WAVE; HEALTH; FRANCE;
D O I
10.1016/j.enbuild.2018.10.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heatwaves are responsible for many deaths due to hot weather. Natural ventilation is promoted as a cooling solution to reduce the impacts of climate change because of its energy-saving potential. This paper addresses the prediction of heat-related health risk situations in naturally ventilated dwellings, where indoor thermal conditions depend on external climate and occupant behaviour. Thus, the operating limits of a dwelling vary according to its dynamic thermal response to indoor and outdoor stresses. To secure a building design, a method to improve the prediction of heat-related health risks is proposed that links predicted percentage dissatisfied (PPD) and wet-bulb globe temperature (WBGT) indicators to distinguish a moderately warm situation from a heat stress situation (WBGT > 29 degrees C). Simulations are performed for a dwelling during the 2015 heatwave in Paris (France) to test the method. In the example, natural ventilation was found to reduce the indoor temperature, but there remains ambiguity regarding the ability of natural ventilation to provide moderate conditions. According to the scope of the ergonomic standards, "moderate thermal environment" and "heat stress" temperature ranges are not contiguous. Bridging of this gap requires establishing thermal comfort ranges and heat stress thresholds adapted to people according to their acclimatisation level and their sensitivity to heat. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:408 / 417
页数:10
相关论文
共 52 条
[1]  
[Anonymous], 2007, Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics
[2]  
[Anonymous], 2001, 140 ASHRAE ANSIASHRA, P92
[3]  
[Anonymous], 2001, 11399 ISO AFNOR
[4]  
[Anonymous], 2008, REUSSIR PROJET EFFIN
[5]  
[Anonymous], 2014, PANTIN ECOLE FRAICHE
[6]  
[Anonymous], 2007, 15242 EN AFNOR
[7]  
[Anonymous], 1994, 7243 ISO AFNOR
[8]  
[Anonymous], 2004, 15265 ISO AFNOR
[9]  
[Anonymous], 2002, 7726 ISO
[10]  
[Anonymous], 2016, GUID ADDR CLIM CHANG, P42