Effect of Radial Head Implant Shape on Radiocapitellar Joint Congruency

被引:5
|
作者
Lalone, Emily A. [1 ]
Shannon, Hannah L. [1 ]
Deluce, Simon R. [1 ]
Giles, Joshua W. [1 ]
King, Graham J. W. [1 ,2 ]
Johnson, James A. [1 ,3 ]
机构
[1] Univ Western Ontario, St Josephs Hosp, Roth McFarlane Hand & Upper Limb Ctr, Bioengn Lab, London, ON, Canada
[2] Univ Western Ontario, Dept Surg, London, ON, Canada
[3] Univ Western Ontario, Dept Mech & Mat Engn, Claudette MacKay Lassonde Pavil,Room 1307, London, ON N6A 5B9, Canada
来源
关键词
Radius; arthroplasty; 3-dimensional reconstruction; computed tomographic imaging; joint contact mechanics; IMAGE-BASED TECHNIQUE; IN-VITRO; CONTACT MECHANICS; ELBOW FLEXION; ARTHROPLASTY; PROSTHESIS; DESIGN; KINEMATICS; STABILITY; REPAIR;
D O I
10.1016/j.jhsa.2017.03.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Radial head arthroplasty is indicated in displaced fractures in which comminution precludes successful internal fixation. Many types of radial head implants have been developed varying in material, methods of fixation, and degrees of modularity and geometry. The purpose of this study was to investigate the effect of radial head implant shape on radiocapitellar joint congruency. Methods Joint congruency was quantified in 7 cadaveric specimens employing a registration and inter-surface distance algorithm and 3-dimensional models obtained using computed tomography. Forearm rotation was simulated after computer-guided implantation of an axisymmetric radial head, a population-based quasi-anatomic radial head implant, and a reverse-engineered anatomic radial head implant. Inter-surface distances were measured to investigate the relative position of the radial head implant and displayed on 3-dimensional color-contour maps. Surface area was measured for inter-surface distances (1.5 mm) and compared for each radial head geometry. Results There were no statistical differences in the contact surface area between radial head implants during active or passive forearm rotation. The joint was more congruent (larger contact surface area) during active forearm rotation compared with passive forearm rotation. Conclusions This study investigated the effect of implant geometry on the radiocapitellar joint contact mechanics by examining a commercially available radial head system (axisymmetric), a quasi-anatomic design, and an anatomic reverse-engineered radial head implant. We found no statistical differences in radiocapitellar joint contact mechanics as measured by 3-dimensional joint congruency in cadaveric specimens undergoing continuous simulated forearm rotation. Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:476.e1 / 476.e11
页数:11
相关论文
共 50 条
  • [41] Screw placement in arthroscopically assisted osteosynthesis of radial head fractures using a reference k-wire in the radiocapitellar joint: a cadaveric study
    Camenzind, Roland S.
    Cucchi, Davide
    Leschinger, Tim
    Hackl, Michael
    Mueller, Lars P.
    Wegmann, Kilian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4111 - 4116
  • [42] Screw placement in arthroscopically assisted osteosynthesis of radial head fractures using a reference k-wire in the radiocapitellar joint: a cadaveric study
    Roland S. Camenzind
    Davide Cucchi
    Tim Leschinger
    Michael Hackl
    Lars P. Müller
    Kilian Wegmann
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4111 - 4116
  • [43] The noncircular shape of the radial head
    van Riet, RP
    Van Glabbeek, F
    Neale, PG
    Bortier, H
    An, KN
    O'Driscoll, SW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (06): : 972 - 978
  • [44] Type A ganglion cysts of the radiocapitellar joint may involve compression of the superficial radial nerve
    Miralles, J. Rodriguez
    Cisneros, L. Natera
    Escola, A.
    Fallone, J. C.
    Cots, M.
    Espiga, X.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (06) : 791 - 794
  • [45] Effect of Radiocapitellar Joint Over/Under Stuffing on Elbow Joint Contact Pressure
    Ramazanian, Taghi
    Mueller-Lebschi, Julia A.
    Merlet, Marie-Caroline H.
    Lee, HoMin
    Vaichinger, Anthony M.
    Fitzsimmons, James S.
    Driscoll, Shawn W. O'
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (04): : 403.e1 - 403.e9
  • [46] Arthroscopic matched osteoplasty of the radial head for painful radiocapitellar osteoarthritis: surgical technique and case series
    Rotman, Dani
    Watts, Adam C.
    CLINICS IN SHOULDER AND ELBOW, 2024, 27 (03): : 309 - 315
  • [47] Arthroscopic Radial Head Implant Removal and Resection
    Bhatia, Deepak N.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (04): : E705 - E711
  • [48] The Effect of Malunited Scaphoid Fractures on Joint Congruency
    Ranota, Puneet
    Seltser, Anna
    Suh, Nina
    Grewal, Ruby
    MacDermid, Joy C.
    Lalone, Emily
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (11): : 1024.e1 - 1024.e8
  • [49] RADIAL HEAD FRACTURES AND THEIR EFFECT ON THE DISTAL RADIOULNAR JOINT - A RATIONALE FOR TREATMENT
    GEEL, CW
    PALMER, AK
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (275) : 79 - 84
  • [50] The effect of stem fit on the radiocapitellar contact mechanics of a metallic axisymmetric radial head hemiarthroplasty: is loose fit better than rigidly fixed?
    Szmit, Jakub
    King, Graham J. W.
    Johnson, James A.
    Langohr, Daniel G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (12) : 2394 - 2399