Effect of Radial Head Implant Shape on Radiocapitellar Joint Congruency

被引:5
|
作者
Lalone, Emily A. [1 ]
Shannon, Hannah L. [1 ]
Deluce, Simon R. [1 ]
Giles, Joshua W. [1 ]
King, Graham J. W. [1 ,2 ]
Johnson, James A. [1 ,3 ]
机构
[1] Univ Western Ontario, St Josephs Hosp, Roth McFarlane Hand & Upper Limb Ctr, Bioengn Lab, London, ON, Canada
[2] Univ Western Ontario, Dept Surg, London, ON, Canada
[3] Univ Western Ontario, Dept Mech & Mat Engn, Claudette MacKay Lassonde Pavil,Room 1307, London, ON N6A 5B9, Canada
来源
关键词
Radius; arthroplasty; 3-dimensional reconstruction; computed tomographic imaging; joint contact mechanics; IMAGE-BASED TECHNIQUE; IN-VITRO; CONTACT MECHANICS; ELBOW FLEXION; ARTHROPLASTY; PROSTHESIS; DESIGN; KINEMATICS; STABILITY; REPAIR;
D O I
10.1016/j.jhsa.2017.03.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Radial head arthroplasty is indicated in displaced fractures in which comminution precludes successful internal fixation. Many types of radial head implants have been developed varying in material, methods of fixation, and degrees of modularity and geometry. The purpose of this study was to investigate the effect of radial head implant shape on radiocapitellar joint congruency. Methods Joint congruency was quantified in 7 cadaveric specimens employing a registration and inter-surface distance algorithm and 3-dimensional models obtained using computed tomography. Forearm rotation was simulated after computer-guided implantation of an axisymmetric radial head, a population-based quasi-anatomic radial head implant, and a reverse-engineered anatomic radial head implant. Inter-surface distances were measured to investigate the relative position of the radial head implant and displayed on 3-dimensional color-contour maps. Surface area was measured for inter-surface distances (1.5 mm) and compared for each radial head geometry. Results There were no statistical differences in the contact surface area between radial head implants during active or passive forearm rotation. The joint was more congruent (larger contact surface area) during active forearm rotation compared with passive forearm rotation. Conclusions This study investigated the effect of implant geometry on the radiocapitellar joint contact mechanics by examining a commercially available radial head system (axisymmetric), a quasi-anatomic design, and an anatomic reverse-engineered radial head implant. We found no statistical differences in radiocapitellar joint contact mechanics as measured by 3-dimensional joint congruency in cadaveric specimens undergoing continuous simulated forearm rotation. Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:476.e1 / 476.e11
页数:11
相关论文
共 50 条
  • [21] Elbow Biomechanics, Radiocapitellar Joint Pressure, and Interosseous Membrane Strain Before and After Radial Head Arthroplasty
    Hemmingsen, Chalotte K.
    Thillemann, Theis M.
    Elmengaard, Brian
    de Raedt, Sepp
    Nielsen, Emil T.
    Mosegaard, Sebastian B.
    Stentz-Olesen, Kasper
    Stilling, Maiken
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (03) : 510 - 522
  • [22] Unique application of a metacarpophalangeal joint implant as a radial head prosthesis
    Duncan, Scott F. M.
    Briski, David C.
    Steinmann, Scott P.
    Adams, Julie
    Kakinoki, Ryosuke
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (12) : E308 - E312
  • [23] The role of radial head morphology in proximal radioulnar joint congruency during forearm rotation
    Zhang, Hailong
    Yang, Guang
    Lu, Yi
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (04)
  • [24] Radial head translation measurement in healthy individuals: the radiocapitellar ratio
    Rouleau, Dominique M.
    Sandman, Emilie
    Canet, Fanny
    Djahangiri, Ali
    Laflamme, Yves
    Athwal, George S.
    Petit, Yvan
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (05) : 574 - 579
  • [25] Radiocapitellar and Ulnotrochlear Pressures Increase in a Radial Head Fracture Model
    France, Thomas
    Lockwood, Winthrop
    Gu, Songyuan
    Tucker, Nick
    Baldini, Todd
    Lauder, Alexander
    Catalano III, Louis W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2024, 106 (07): : 600 - 607
  • [26] Incarceration of the Radial Head Associated With a Radial Head Fracture, Radiocapitellar Dislocation, and Proximal Radioulnar Translocation In Response
    Min, William
    McLaurin, Toni M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (09) : E94 - E94
  • [27] The biomechanical effect of radial shortening on the radiocapitellar articulation
    Diab, M
    Poston, JM
    Huber, P
    Tencer, AF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 879 - 883
  • [28] Radiocapitellar contact characteristics during prosthetic radial head subluxation
    Sahu, Dipit
    Fitzsimmons, James S.
    Thoreson, Andrew R.
    An, Kai-Nan
    O'Driscoll, Shawn W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (01) : 170 - 177
  • [29] Radiocapitellar stability: the effect of soft tissue integrity on bipolar versus monopolar radial head prostheses
    Chanlalit, Cholawish
    Shukla, Dave R.
    Fitzsimmons, James S.
    Thoreson, Andrew R.
    An, Kai-Nan
    O'Driscoll, Shawn W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (02) : 219 - 225
  • [30] The impact of anatomic alignment on radiocapitellar pressure following radial head arthroplasty
    Heifner, John J.
    Lacau, Gustavo E.
    Forro, Stephen D.
    Davis, Ty A.
    Mercer, Deana M.
    Rubio, Francisco