Effect of Radial Head Implant Shape on Radiocapitellar Joint Congruency

被引:5
|
作者
Lalone, Emily A. [1 ]
Shannon, Hannah L. [1 ]
Deluce, Simon R. [1 ]
Giles, Joshua W. [1 ]
King, Graham J. W. [1 ,2 ]
Johnson, James A. [1 ,3 ]
机构
[1] Univ Western Ontario, St Josephs Hosp, Roth McFarlane Hand & Upper Limb Ctr, Bioengn Lab, London, ON, Canada
[2] Univ Western Ontario, Dept Surg, London, ON, Canada
[3] Univ Western Ontario, Dept Mech & Mat Engn, Claudette MacKay Lassonde Pavil,Room 1307, London, ON N6A 5B9, Canada
来源
关键词
Radius; arthroplasty; 3-dimensional reconstruction; computed tomographic imaging; joint contact mechanics; IMAGE-BASED TECHNIQUE; IN-VITRO; CONTACT MECHANICS; ELBOW FLEXION; ARTHROPLASTY; PROSTHESIS; DESIGN; KINEMATICS; STABILITY; REPAIR;
D O I
10.1016/j.jhsa.2017.03.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Radial head arthroplasty is indicated in displaced fractures in which comminution precludes successful internal fixation. Many types of radial head implants have been developed varying in material, methods of fixation, and degrees of modularity and geometry. The purpose of this study was to investigate the effect of radial head implant shape on radiocapitellar joint congruency. Methods Joint congruency was quantified in 7 cadaveric specimens employing a registration and inter-surface distance algorithm and 3-dimensional models obtained using computed tomography. Forearm rotation was simulated after computer-guided implantation of an axisymmetric radial head, a population-based quasi-anatomic radial head implant, and a reverse-engineered anatomic radial head implant. Inter-surface distances were measured to investigate the relative position of the radial head implant and displayed on 3-dimensional color-contour maps. Surface area was measured for inter-surface distances (1.5 mm) and compared for each radial head geometry. Results There were no statistical differences in the contact surface area between radial head implants during active or passive forearm rotation. The joint was more congruent (larger contact surface area) during active forearm rotation compared with passive forearm rotation. Conclusions This study investigated the effect of implant geometry on the radiocapitellar joint contact mechanics by examining a commercially available radial head system (axisymmetric), a quasi-anatomic design, and an anatomic reverse-engineered radial head implant. We found no statistical differences in radiocapitellar joint contact mechanics as measured by 3-dimensional joint congruency in cadaveric specimens undergoing continuous simulated forearm rotation. Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:476.e1 / 476.e11
页数:11
相关论文
共 50 条
  • [1] The effect of radial head implant shape on radiocapitellar kinematics during in vitro forearm rotation
    Shannon, Hannah L.
    Deluce, Simon R.
    Giles, Joshua W.
    Johnson, James A.
    King, Graham J. W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (02) : 258 - 264
  • [2] The effect of radial head fracture size on radiocapitellar joint stability
    Beingessner, DM
    Dunning, CE
    Beingessner, CJ
    Johnson, JA
    King, GJW
    CLINICAL BIOMECHANICS, 2003, 18 (07) : 677 - 681
  • [3] The effect of metallic radial head arthroplasty on radiocapitellar joint contact area
    Liew, VS
    Cooper, IC
    Ferreira, LM
    Johnson, JA
    King, GJW
    CLINICAL BIOMECHANICS, 2003, 18 (02) : 115 - 118
  • [4] The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint
    Van Riet, R. P.
    Van Glabbeek, F.
    Baumfeld, J. A.
    Neale, P. G.
    Morrey, B. F.
    O'Driscoll, S. W.
    An, K. N.
    CLINICAL BIOMECHANICS, 2006, 21 (06) : 554 - 559
  • [5] Effect of radial head malunion on radiocapitellar stability
    Shukla, Dave R.
    Fitzsimmons, James S.
    An, Kai-Nan
    O'Driscoll, Shawn W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (06) : 789 - 794
  • [6] The Effect of Prosthetic Radial Head Geometry on the Distribution and Magnitude of Radiocapitellar Joint Contact Pressures
    Bachman, Daniel R.
    Thaveepunsan, Sutee
    Park, Sangeun
    Fitzsimmons, James S.
    An, Kai-Nan
    O'Driscoll, Shawn W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (02): : 281 - 288
  • [7] The Effect of Radial Head Implant Length on Radiocapitellar Articular Properties and Load Transfer Within the Forearm
    Lanting, Brent A.
    Ferreira, Louis M.
    Johnson, James A.
    King, Graham J. W.
    Athwal, George S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (06) : 348 - 353
  • [8] Radiocapitellar Joint Contact Pressures Following Radial Head Arthroplasty
    Cohn, Michael
    Glait, Sergio A.
    Sapienza, Anthony
    Kwon, Young W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (08): : 1566 - 1571
  • [9] Radiocapitellar joint contacts after bipolar radial head arthroplasty
    Moungondo, Fabian
    El Kazzi, Wissam
    van Riet, Roger
    Feipel, Veronique
    Rooze, Marcel
    Schuind, Frederic
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (02) : 230 - 235
  • [10] Effect of Radial Head Implant Shape on Joint Contact Area and Location During Static Loading
    Shannon, Hannah L.
    Deluce, Simon R.
    Lalone, Emily A.
    Willing, Ryan
    King, Graham J. W.
    Johnson, James A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (04): : 716 - 722