Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease

被引:28
作者
Gustafsson, Ingemar [1 ]
Bergstrom, Anders [1 ]
Myers, Anna Cardiakides [2 ]
Ivarsen, Anders [3 ]
Hjortdal, Jesper [3 ]
机构
[1] Lund Univ, Skane Univ Hosp, Dept Clin Sci Lund, Ophthalmol, Lund, Sweden
[2] Lund Univ, Fac Med, Dept Clin Sci, Lund, Sweden
[3] Aarhus Univ Hosp, Dept Ophthalmol, Aarhus, Denmark
来源
PLOS ONE | 2020年 / 15卷 / 02期
关键词
COLLAGEN CROSS-LINKING; ULTRAVIOLET; RIBOFLAVIN;
D O I
10.1371/journal.pone.0228992
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. Methods Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). Results Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11-1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46-0.56 D) and the AK (0.54 D, 95% CI 0.48-0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. Conclusions The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.
引用
收藏
页数:10
相关论文
共 26 条
  • [1] [Anonymous], PLOS ONE
  • [2] A nationwide population-based study of social demographic factors, associated diseases and mortality of keratoconus patients in Denmark from 1977 to 2015
    Bak-Nielsen, Sashia
    Ramlau-Hansen, Cecilia H.
    Ivarsen, Anders
    Plana-Ripoll, Oleguer
    Hjortdal, Jesper
    [J]. ACTA OPHTHALMOLOGICA, 2019, 97 (05) : 497 - 504
  • [3] Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables
    Bartlett, J. W.
    Frost, C.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) : 466 - 475
  • [4] Tomographic Parameters for the Detection of Keratoconus: Suggestions for Screening and Treatment Parameters
    Belin, Michael W.
    Villavicencio, Ovette F.
    Ambrosio, Renato R., Jr.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (06): : 326 - 330
  • [5] Bland J M., 1996, BMJ
  • [6] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [7] Statistics notes: Measurement error proportional to the mean .23.
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 313 (7049) : 106 - 106
  • [8] Differential precision of corneal Pentacam HR measurements in early and advanced keratoconus
    Flynn, Tom H.
    Sharma, Daya P.
    Bunce, Catey
    Wilkins, Mark R.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) : 1183 - 1187
  • [9] Age-specific Incidence and Prevalence of Keratoconus: A Nationwide Registration Study
    Godefrooij, Daniel A.
    De Wit, G. Ardine
    Uiterwaal, Cuno S.
    Imhof, Saskia M.
    Wisse, Robert P. L.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 175 : 169 - 172
  • [10] Nationwide reduction in the number of corneal transplantations for keratoconus following the implementation of cross-linking
    Godefrooij, Daniel A.
    Gans, Renze
    Imhof, Saskia M.
    Wisse, Robert P. L.
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (07) : 675 - 678