A Simple Open-Circuit Detection Strategy for a Single-Phase Grid-Connected PV Inverter Fed From Power Optimizers
被引:18
作者:
Dong, Mi
论文数: 0引用数: 0
h-index: 0
机构:
Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R ChinaCent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
Dong, Mi
[1
]
Dong, Hui
论文数: 0引用数: 0
h-index: 0
机构:
Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R ChinaCent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
Dong, Hui
[1
]
Wang, Lina
论文数: 0引用数: 0
h-index: 0
机构:
Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R ChinaCent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
Wang, Lina
[2
]
Yang, Jian
论文数: 0引用数: 0
h-index: 0
机构:
Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R ChinaCent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
Yang, Jian
[1
]
Li, Li
论文数: 0引用数: 0
h-index: 0
机构:
Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R ChinaCent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
Li, Li
[1
]
Wang, Yinghua
论文数: 0引用数: 0
h-index: 0
机构:
State Grid Huangshi Elect Power Supply Co, Huangshi 435000, Peoples R ChinaCent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
Wang, Yinghua
[3
]
机构:
[1] Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
[2] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
[3] State Grid Huangshi Elect Power Supply Co, Huangshi 435000, Peoples R China
Grid-connected photovoltaic (PV) system;
inverter;
maximum power point (MPP);
open-circuit fault (OCF);
power optimizer (PO);
MOTOR DRIVE SYSTEMS;
FAULT;
DIAGNOSIS;
DESIGN;
D O I:
10.1109/TPEL.2017.2751508
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
A simple and real-time open-circuit fault(OCF) detection method is proposed for a single-phase grid-connected photovoltaic inverter fed by series-connected power optimizers (POs). To implement the proposed method, PO controllers periodically monitor POs' output voltage variations and calculate output voltage residual errors. Then, on the PO side, the OCF identification rule for the inverter is developed, which is based on the amount of voltage variation and the improved judgment criterion derived from voltage residual error and power. The proposed OCF detection method is of low cost and is real time, needing no extra hardware and no communication between the inverter and POs. Generally speaking, the method provides a reliable and fast solution to detect OCFs in the series-connected distributed dc power or energy storage systems. Its effectiveness and reliability are verified by experimental results.