Laboratory calibration of time domain reflectometry to determine moisture content in undisturbed peat samples

被引:25
作者
Nagare, R. M. [1 ]
Schincariol, R. A. [1 ]
Quinton, W. L. [2 ]
Hayashi, M. [3 ]
机构
[1] Univ Western Ontario, Dept Earth Sci, London, ON N6A 5B7, Canada
[2] Wilfrid Laurier Univ, Cold Reg Res Ctr, Waterloo, ON N2L 3C5, Canada
[3] Univ Calgary, Dept Geol & Geophys, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
SOIL-WATER CONTENT; ELECTRICAL-CONDUCTIVITY; ELECTROMAGNETIC DETERMINATION; DIELECTRIC-CONSTANT; TDR; PERMITTIVITY; BEHAVIOR; PROBES;
D O I
10.1111/j.1365-2389.2011.01351.x
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Time domain reflectometry (TDR), while widely used to measure volumetric water content (theta) and bulk electrical conductivity (BEC) in unsaturated granular soils, remains less studied in peat than mineral soils. Empirical models commonly used in mineral soils are not applicable to peat for accurate determination of theta from measured apparent dielectric permittivity (epsilon). Past studies for peat report highly variable calibrations, and suggest differences in origin of organic matter, degree of decomposition and bound water to explain such variability. This study shows that bound water appears to have minimal impact on calibration because of its negligible volumetric fraction at the low bulk densities of peat. Increased volumetric air fraction at the same theta values attributed to high porosity of peat makes the epsilon-theta relationships of mineral soils inapplicable. Temperature effects on e resulted in a correction factor for theta. The temperature correction factor decreased with decreasing theta and was determined experimentally to lie between -0.0021 m(3) m(-3) per degrees C for theta >= 0.79 m(3) m(-3) and -0.0005 m(3) m(-3) per degrees C for theta = 0.35 m(3) m(-3). The decreasing value of the correction factor with theta can be explained by dependence of the epsilon-theta relationship on properties of free water alone. Temperature dependence of BEC was close to that of soil solution. Maxwell-De Loor's four-phase mixing model (MDL) based on physical properties of the multiphase soil system can efficiently simulate the effect of increased air volume and varying soil temperature on the epsilon-theta relationship in peat. In addition, linear epsilon-theta calibration in peat can be improved when BEC is included in the calibration equation.
引用
收藏
页码:505 / 515
页数:11
相关论文
共 50 条
[31]   Design, calibration, and validation of an inline green coffee moisture estimation system using time-domain reflectometry [J].
Anokye-Bempah, Laudia ;
Phetpan, Kittisak ;
Slaughter, David ;
Donis-Gonzalez, Irwin R. .
JOURNAL OF FOOD ENGINEERING, 2023, 341
[32]   Effects of Temperature on Measurements of Soil Water Content with Time Domain Reflectometry [J].
Schanz, Tom ;
Baille, Wiebke ;
Long Nguyen Tuan .
GEOTECHNICAL TESTING JOURNAL, 2011, 34 (01) :1-8
[33]   Time Domain Reflectometry for Water Content Measurement of Municipal Solid Waste [J].
Chen, Renpeng ;
Chen, Yun ;
Chen, Wei ;
Chen, Yunmin .
ENVIRONMENTAL ENGINEERING SCIENCE, 2012, 29 (06) :486-493
[34]   Time domain reflectometry for water content and density of soils: study of soil-dependent calibration constants [J].
Drnevich, VP ;
Ashmawy, AK ;
Yu, X ;
Sallam, AM .
CANADIAN GEOTECHNICAL JOURNAL, 2005, 42 (04) :1053-1065
[35]   Complex Permittivity Model for Time Domain Reflectometry Soil Water Content Sensing: II. Calibration [J].
Schwartz, R. C. ;
Evett, S. R. ;
Bell, J. M. .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2009, 73 (03) :898-909
[36]   Spatially characterizing apparent electrical conductivity and water content of surface soils with time domain reflectometry [J].
Wraith, JA ;
Robinson, DA ;
Jones, SB ;
Long, DS .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2005, 46 (1-3) :239-261
[37]   Evaluation of Water Content in an Active Layer Using Penetration-Type Time Domain Reflectometry [J].
Lee, Jong-Sub ;
Hong, Won-Taek ;
Park, Keunbo ;
Hong, Seung Seo ;
Lee, Sang-Ho ;
Byun, Yong-Hoon .
APPLIED SCIENCES-BASEL, 2018, 8 (06)
[38]   Calibration for time domain reflectometry modular in digital communication analyzer [J].
Lu Fumin .
PROCEEDINGS OF 2017 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL 1, 2017, :259-262
[39]   IMPROVED CALIBRATION OF FREQUENCY DOMAIN REFLECTOMETRY PROBES FOR VOLUMETRIC WATER CONTENT MEASUREMENTS OF THREE MEDIA [J].
Ting, Y. ;
Chen, C. .
TRANSACTIONS OF THE ASABE, 2012, 55 (01) :51-60
[40]   Application of time domain reflectometry to high suspended sediment concentration measurements: Laboratory validation and preliminary field observations in a steep mountain stream [J].
Miyata, Shusuke ;
Mizugaki, Shigeru ;
Naito, Shuya ;
Fujita, Masaharu .
JOURNAL OF HYDROLOGY, 2020, 585