A Novel Stationary CT Scheme Based on High-Density X-Ray Sources Device

被引:11
作者
Duan, Yiting [1 ]
Cheng, Haitao [1 ]
Wang, Kai [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect & Informat Engn, Xian 710049, Peoples R China
关键词
Computed tomography; Detectors; Image reconstruction; X-ray imaging; Reconstruction algorithms; Iterative methods; Zinc oxide; Stationary CT scheme; high-density X-ray sources devices; source-detector plate; iterative reconstruction; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; CARBON NANOTUBES;
D O I
10.1109/ACCESS.2020.3003308
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the introduction of cold electron sources such as nanotubes, X-ray sources became small in size so that many sources are installed in array to form stationary CT, which brings benefits of simplicity in mechanism and fast response. However, the nanotube-based X-ray source is still singly packaged and hence density of X-ray sources is limited, which introduces severe sparse-view artifacts and could not be used in practice. With the invention of X-ray sources device based on ZnO nanowires as cold electron emitters, a large amount of X-ray sources is first integrated in a flat panel device. In this study, we design a stationary CT architecture using high-density sources devices, called HD-SCT, and develop corresponding reconstruction algorithm. Specifically, several flat panel detectors and X-ray sources devices are spliced together to form a source-detector plate. Multiple source-detector plates are organized as a polygon that encloses object to complete CT scanning. In HD-SCT, X-ray sources are close to object which can significantly decrease CT device volume. The X-ray beam emitted by each source just cover part of object and the spot sources alternately light to completely scan object. Simultaneously, we propose a reconstruction method for the specific configuration which adopts an iterative algorithm to resolve the reconstruction based on alterative part projections, as well as a novel correction process of projection completion for the shadowed area of placing X-ray source devices. To validate the design of the proposed HD-SCT, we execute a series of simulation experiments, which show that the proposed HD-SCT and corresponding reconstruction method effectively remove the artifacts caused by the embed X-ray source device. The results also disclose that with the increase of density of X-ray sources, the resolution of reconstruction has been dramatically improved, which demonstrates the practical value of introducing high-density X-ray sources device into stationary CT design.
引用
收藏
页码:112910 / 112921
页数:12
相关论文
共 50 条
  • [21] Distribution of electron density using dual-energy X-ray CT
    Tsunoo, T
    Torikoshi, M
    Sasaki, M
    Endo, M
    Yagi, N
    Uesugi, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1678 - 1682
  • [22] High-resolution x-ray tomography using laboratory sources
    Tkachuk, Andrei
    Feser, Michael
    Cui, Hongtao
    Duewer, Fred
    Chang, Hauyee
    Yuri, Wenbing
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [23] Nanomaterial-based x-ray sources
    Cole, Matthew T.
    Parmee, R. J.
    Milne, William I.
    NANOTECHNOLOGY, 2016, 27 (08)
  • [24] LOW-DOSE X-RAY CT RECONSTRUCTION BASED ON JOINT SINOGRAM SMOOTHING AND LEARNED DICTIONARY-BASED REPRESENTATION
    Stojanovic, Ivana
    Pien, Homer
    Do, Synho
    Karl, W. Clem
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1012 - 1015
  • [25] Development of high-energy and high-resolution X-ray CT
    Sato, Katsutoshi
    Abe, Makoto
    Takatsuji, Toshiyuki
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2018, 54 : 276 - 283
  • [26] High-Quality Parallel-Ray X-Ray CT Back Projection Using Optimized Interpolation
    McCann, Michael T.
    Unser, Michael
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2017, 26 (10) : 4639 - 4647
  • [27] High-Performance Hybrid Bismuth-Carbon Nanotube Based Contrast Agent for X-ray CT Imaging
    Hernandez-Rivera, Mayra
    Kumar, Ish
    Cho, Stephen Y.
    Cheong, Benjamin Y.
    Pulikkathara, Merlyn X.
    Moghaddam, Sakineh E.
    Whitmire, Kenton H.
    Wilson, Lon J.
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (07) : 5709 - 5716
  • [28] l0 regularization based on a prior image incorporated non-local means for limited-angle X-ray CT reconstruction
    Zhang, Lingli
    Zeng, Li
    Guo, Yumeng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (03) : 481 - 498
  • [29] Metal Artifact Reduction in X-ray CT Imaging based on Iterative Reconstruction Approach
    Nawaz, Shoukat
    Jian, Fu
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2420 - 2425
  • [30] Regularization Analysis and Design for Prior-Image-Based X-Ray CT Reconstruction
    Zhang, Hao
    Gang, Grace J.
    Dang, Hao
    Stayman, J. Webster
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (12) : 2675 - 2686