A Novel Stationary CT Scheme Based on High-Density X-Ray Sources Device

被引:11
|
作者
Duan, Yiting [1 ]
Cheng, Haitao [1 ]
Wang, Kai [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect & Informat Engn, Xian 710049, Peoples R China
关键词
Computed tomography; Detectors; Image reconstruction; X-ray imaging; Reconstruction algorithms; Iterative methods; Zinc oxide; Stationary CT scheme; high-density X-ray sources devices; source-detector plate; iterative reconstruction; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; CARBON NANOTUBES;
D O I
10.1109/ACCESS.2020.3003308
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the introduction of cold electron sources such as nanotubes, X-ray sources became small in size so that many sources are installed in array to form stationary CT, which brings benefits of simplicity in mechanism and fast response. However, the nanotube-based X-ray source is still singly packaged and hence density of X-ray sources is limited, which introduces severe sparse-view artifacts and could not be used in practice. With the invention of X-ray sources device based on ZnO nanowires as cold electron emitters, a large amount of X-ray sources is first integrated in a flat panel device. In this study, we design a stationary CT architecture using high-density sources devices, called HD-SCT, and develop corresponding reconstruction algorithm. Specifically, several flat panel detectors and X-ray sources devices are spliced together to form a source-detector plate. Multiple source-detector plates are organized as a polygon that encloses object to complete CT scanning. In HD-SCT, X-ray sources are close to object which can significantly decrease CT device volume. The X-ray beam emitted by each source just cover part of object and the spot sources alternately light to completely scan object. Simultaneously, we propose a reconstruction method for the specific configuration which adopts an iterative algorithm to resolve the reconstruction based on alterative part projections, as well as a novel correction process of projection completion for the shadowed area of placing X-ray source devices. To validate the design of the proposed HD-SCT, we execute a series of simulation experiments, which show that the proposed HD-SCT and corresponding reconstruction method effectively remove the artifacts caused by the embed X-ray source device. The results also disclose that with the increase of density of X-ray sources, the resolution of reconstruction has been dramatically improved, which demonstrates the practical value of introducing high-density X-ray sources device into stationary CT design.
引用
收藏
页码:112910 / 112921
页数:12
相关论文
共 50 条
  • [11] ROBUST FRAME BASED X-RAY CT RECONSTRUCTION
    Li, Jia
    Miao, Chuang
    Shen, Zuowei
    Wang, Ge
    Yu, Hengyong
    JOURNAL OF COMPUTATIONAL MATHEMATICS, 2016, 34 (06) : 683 - 704
  • [12] Noise reduction for low-dose X-ray CT based on fuzzy logical in stationary wavelet domain
    Liu, Yi
    Gui, Zhiguo
    Zhang, Quan
    OPTIK, 2013, 124 (18): : 3348 - 3352
  • [13] Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction
    Fahimian, Benjamin P.
    Zhao, Yunzhe
    Huang, Zhifeng
    Fung, Russell
    Mao, Yu
    Zhu, Chun
    Khatonabadi, Maryam
    DeMarco, John J.
    Osher, Stanley J.
    McNitt-Gray, Michael F.
    Miao, Jianwei
    MEDICAL PHYSICS, 2013, 40 (03)
  • [14] Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
    Yu, Zhou
    Thibault, Jean-Baptiste
    Bouman, Charles A.
    Sauer, Ken D.
    Hsieh, Jiang
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2011, 20 (01) : 161 - 175
  • [15] Feasibility of a stationary head CT scanner using a CNT x-ray source array
    Spronk, Derrek
    Luo, Yueting
    Inscoe, Christy
    Billingsley, Alex
    Lee, Yueh Z.
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [16] Volumetric Imaging and Reconstruction with Stationary Head CT System using Carbon Nanotube X-ray Source Arrays
    Luo, Yueting
    Spronk, Derrek
    Billingsley, Alex
    Inscoe, Christina R.
    Lee, Yueh Z.
    Zhou, Otto
    Lu, Jianping
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [17] A new imaging mode based on X-ray CT as prior image and sparsely sampled projections for rapid clinical proton CT
    Yang, Yu-Qing
    Fang, Wen-Cheng
    Huang, Xiao-Xia
    Du, Qiang
    Li, Ming
    Zheng, Jian
    Zhao, Zhen-Tang
    NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (08)
  • [18] Directional information of the simultaneously active X-ray sources and fast CT reconstruction
    Saha, Sajib
    Tahtali, Murat
    Lambert, Andrew
    Pickering, Mark
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [19] Rectangular Fixed-Gantry CT Prototype: Combining CNT X-Ray Sources and Accelerated Compressed Sensing-Based Reconstruction
    Gonzales, Brian
    Spronki, Derrek
    Cheng, Yuan
    Tucker, Andrew W.
    Beckman, Moritz
    Zhou, Otto
    Lu, Jianping
    IEEE ACCESS, 2014, 2 : 971 - 981
  • [20] A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning
    Zhang, Cheng
    Zhang, Tao
    Zheng, Jian
    Li, Ming
    Lu, Yanfei
    You, Jiali
    Guan, Yihui
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2015, 2015