A Novel Stationary CT Scheme Based on High-Density X-Ray Sources Device

被引:11
|
作者
Duan, Yiting [1 ]
Cheng, Haitao [1 ]
Wang, Kai [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect & Informat Engn, Xian 710049, Peoples R China
关键词
Computed tomography; Detectors; Image reconstruction; X-ray imaging; Reconstruction algorithms; Iterative methods; Zinc oxide; Stationary CT scheme; high-density X-ray sources devices; source-detector plate; iterative reconstruction; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; CARBON NANOTUBES;
D O I
10.1109/ACCESS.2020.3003308
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the introduction of cold electron sources such as nanotubes, X-ray sources became small in size so that many sources are installed in array to form stationary CT, which brings benefits of simplicity in mechanism and fast response. However, the nanotube-based X-ray source is still singly packaged and hence density of X-ray sources is limited, which introduces severe sparse-view artifacts and could not be used in practice. With the invention of X-ray sources device based on ZnO nanowires as cold electron emitters, a large amount of X-ray sources is first integrated in a flat panel device. In this study, we design a stationary CT architecture using high-density sources devices, called HD-SCT, and develop corresponding reconstruction algorithm. Specifically, several flat panel detectors and X-ray sources devices are spliced together to form a source-detector plate. Multiple source-detector plates are organized as a polygon that encloses object to complete CT scanning. In HD-SCT, X-ray sources are close to object which can significantly decrease CT device volume. The X-ray beam emitted by each source just cover part of object and the spot sources alternately light to completely scan object. Simultaneously, we propose a reconstruction method for the specific configuration which adopts an iterative algorithm to resolve the reconstruction based on alterative part projections, as well as a novel correction process of projection completion for the shadowed area of placing X-ray source devices. To validate the design of the proposed HD-SCT, we execute a series of simulation experiments, which show that the proposed HD-SCT and corresponding reconstruction method effectively remove the artifacts caused by the embed X-ray source device. The results also disclose that with the increase of density of X-ray sources, the resolution of reconstruction has been dramatically improved, which demonstrates the practical value of introducing high-density X-ray sources device into stationary CT design.
引用
收藏
页码:112910 / 112921
页数:12
相关论文
共 50 条
  • [1] A new CT architecture with stationary x-ray sources
    Cao, Guohua
    Liu, Baodong
    Yu, Hengyong
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [2] A Novel Detector Geometry for X-Ray CT
    Hsieh, Jiang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (05) : 453 - 458
  • [3] Flat-Panel Addressable Cold-Cathode X-Ray Source-Based Stationary CT Architecture
    Wu, Weiwen
    Zhang, Jianjia
    Wang, Shaoyu
    Chen, Jun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [4] Evaluation of electrical crosstalk in high-density photodiode arrays for X-ray imaging applications
    Ji, Fan
    Juntunen, Mikko
    Hietanen, Iiro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 28 - 30
  • [5] An iterative projection-based motion estimation and compensation scheme for head x-ray CT
    Sun, Tao
    Kim, Jung-Ha
    Fulton, Roger
    Nuyts, Johan
    MEDICAL PHYSICS, 2016, 43 (10) : 5705 - 5716
  • [6] A Multiscale Reconstruction Framework Based on Edge-Enhanced Guidance for In-Line X-Ray Phase-Contrast CT With Limited-Angle Projections
    Li, Yimin
    Zhao, Yuanyuan
    Ma, Chenyang
    Li, Fangzhi
    Wang, Ziyao
    Lv, Wenjuan
    Ji, Dongjiang
    Jian, Jianbo
    Zhao, Xinyan
    Zhao, Yuqing
    Hu, Chunhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [7] A Parametric Physical Model-Based X-Ray Spectrum Estimation Approach for CT Imaging
    Chang, Shaojie
    Zhang, Chaoyang
    Mou, Xuanqin
    Xu, Qiong
    He, Lijun
    Chen, Xi
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (05) : 532 - 539
  • [8] A prior-based metal artifact reduction algorithm for x-ray CT
    Li, Ming
    Zheng, Jian
    Zhang, Tao
    Guan, Yihui
    Xu, Pin
    Sun, Mingshan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (02) : 229 - 241
  • [9] A Stationary Head CT Prototype with CNT X-ray Source Arrays
    Spronk, Derrek
    Luo, Yueting
    Billingsley, Alex
    Inscoe, Christina R.
    Zhou, Otto
    Lu, Jianping
    Lee, Yueh Z.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [10] Stationary Head CT Scanner using CNT X-ray Source Arrays
    Spronk, Derrek
    Luo, Yueting
    Inscoe, Christina R.
    Zhou, Otto
    Lu, Jianping
    Lee, Yueh Z.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595