Biomechanical evaluation of the reconstruction of the calcar femorale in femoral neck fractures: a comparative finite element analysis

被引:2
|
作者
Gao, Zhihao [1 ,2 ,3 ]
Ma, Jianxiong [1 ,2 ,3 ]
Wang, Ying [1 ,2 ]
Lu, Bin [1 ,2 ]
Bai, Haohao [1 ,2 ]
Sun, Lei [1 ,2 ]
Jin, Hongzhen [1 ,2 ]
Zhang, Zijian [1 ,2 ,3 ]
Ma, Xinlong [1 ,2 ,3 ]
机构
[1] Tianjin Univ, Tianjin Hosp, 406 Jiefang South Rd, Tianjin 300211, Peoples R China
[2] Tianjin Univ, Tianjin Hosp, Tianjin Key Lab Orthoped Biomech & Med Engn, 155 MuNan Rd, Tianjin, Peoples R China
[3] Tianjin Univ, Acad Med Engn & Translat Med, 92 WeiJin Rd, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanics; femoral neck fractures; finite element analysis; internal fixators; model; cannulated screws; INTERNAL-FIXATION; SCREW FIXATION; ANGLE; RISK;
D O I
10.1177/03000605221112043
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective Femoral neck fractures are common. We evaluated the biomechanical performance of an internal fixation method based on traditional three cannulated screws (3CS) inserted from below the fracture in the direction of the calcar femorale in the treatment of Pauwels III femoral neck fracture. Methods We constructed and evaluated a three-dimensional model of a Pauwels III femoral neck fracture with four models of internal fixation (3CS, and 150 degrees, 155 degrees, and 160 degrees nailing angles) for reconstruction of the calcar femorale, by finite element analysis (FEA). Results The peak stress values at the fracture ends in the 3CS, 150 degrees, 155 degrees, and 160 degrees nailing angle models were 30.052 MPa, 33.382 MPa, 34.012 MPa, and 29.858 MPa; peak stress values for internal fixed stress were 315.121 MPa, 228.819 MPa, 198.173 MPa, and 208.798 MPa; and the maximum displacement of the femoral head was 13.190 mm, 13.183 mm, 12.443 mm, and 12.896 mm, respectively. Conclusion FEA showed that the new nailing methods and the 160 degrees nailing angle for reconstruction of the calcar femorale showed better performance in resisting shearing force for Pauwels III femoral neck fracture, with better mechanical properties, than those with the other three models. These findings can provide a clinical reference.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Biomechanical evaluation of implant techniques for ipsilateral femoral neck and shaft fractures: A finite element analysis
    Xiao, Yukun
    He, Kui
    Tan, Xiaoqi
    Wei, Daiqing
    Yan, Jiyuan
    Yang, Yunkang
    Xiang, Feifan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2025, 164
  • [2] Biomechanical analysis of various internal fracture fixation devices used for treating femoral neck fractures: A comparative finite element analysis
    Mahapatra, Biswajit
    Pal, Bidyut
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (10):
  • [3] Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis
    Zhong, Zhou
    Lan, Xuejun
    Xiang, Zhou
    Duan, Xin
    CLINICAL BIOMECHANICS, 2023, 108
  • [4] Biomechanical evaluation of femoral neck system versus non-sliding fixation in the treatment of young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Yang Gao
    Zhiyuan Lou
    Peng Jia
    Xiaohu Chang
    Xiaoteng Li
    Xin Tang
    BMC Musculoskeletal Disorders, 26 (1)
  • [5] Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element
    Fan, Zhirong
    Chen, Ping
    Yu, Xiubing
    Li, Xing
    Su, Haitao
    Chen, Haiyun
    Yang, Bing
    Qi, Ji
    Wang, Haizhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [6] Biomechanical evaluation of locked plating fixation for unstable femoral neck fractures
    Bliven, E.
    Sandriesser, S.
    Augat, P.
    von Rueden, C.
    Hackl, S.
    BONE & JOINT RESEARCH, 2020, 9 (06): : 314 - 321
  • [7] Biomechanical difference analysis of new and classic intramedullary nail devices in the treatment of basal femoral neck fractures: finite element analysis
    Tang, Zhongjian
    Zhu, Zhexi
    Lv, Yongxiang
    Lu, Yafei
    Huang, Shaolong
    Zhou, Chengqiang
    Zhang, Yazhong
    Wang, Bin
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [8] Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis
    Huang, Bo-Xuan
    Zhan, Si-Zheng
    Yang, Ming
    Zhang, Dian-Ying
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [9] A quantitative biomechanical study of positive buttress techniques for femoral neck fractures: a finite element analysis
    Wang, Gang
    Wang, Bin
    Tang, Yong
    Yang, Hui-Lin
    CHINESE MEDICAL JOURNAL, 2019, 132 (21) : 2588 - 2593
  • [10] A quantitative biomechanical study of positive buttress techniques for femoral neck fractures: a finite element analysis
    Wang Gang
    Wang Bin
    Tang Yong
    Yang Hui-Lin
    中华医学杂志英文版, 2019, 132 (21) : 2588 - 2593