Simultaneous nitrogen and dissolved methane removal from an upflow anaerobic sludge blanket reactor effluent using an integrated fixed-film activated sludge system

被引:12
|
作者
Allegue, T. [1 ]
Carballo-Costa, M. N. [1 ]
Fernandez-Gonzalez, N. [1 ]
Garrido, J. M. [1 ]
机构
[1] Univ Santiago de Compostela, Sch Engn, Dept Chem Engn, Campus Vida, E-15782 Santiago De Compostela, Spain
关键词
Upflow anaerobic sludge blanket; Methane oxidation; Denitrification; Integrated fixed-film activated sludge; Biofilm carriers; Greenhouse gas; MEMBRANE BIOREACTOR; NITRATE REDUCTION; OXIDATION; DENITRIFICATION; AMMONIA;
D O I
10.1016/j.jenvman.2020.110395
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
One of the main drawbacks of upflow anaerobic sludge blanket (UASB) reactors that treat low-strength sewage at room temperature is related to the low quality of their effluents in terms of dissolved methane, organic matter, and nitrogen content. The present study aims to evaluate the feasibility of using an integrated fixed-film activated sludge (IFAS) system as an alternative post-treatment technology to mitigate the environmental impact of such effluents. For this purpose, a pilot plant composed of a UASB (120 L) followed by an IFAS (66 L) system was operated for 407 days. Special attention was paid to the suspended biomass retention capacity and the dissolved methane and nitrogen removal potential of the IFAS post-treatment system. Furthermore, the role of carriers on denitrification and nitrification processes and the microbial communities present in the biofilm were also analyzed. Average total chemical oxygen demand (CODT) and ammonium removal efficiencies of 92 +/- 3% and around 57 +/- 16% were attained throughout the entire operation, respectively. During a first period in which biomass was maintained in both biofilms and suspension, and nitrite was the main electron acceptor, maximum nitrogen removal and methane removal efficiencies of 32.5 mg TN L-1 and 93% were observed in the IFAS system, respectively. However, throughout the second period, in which suspended biomass was completely washed out from the IFAS system, and nitrate became the main electron acceptor, these values decreased to 18 +/- 4 mg TN Lfeed-1 and 77 +/- 12%, respectively. Surprisingly, throughout the entire operation, it was observed that around 50 and 41% of the total nitrogen and methane removals observed in the IFAS system, respectively, were carried out in the aerobic compartment. Aerobic methane oxidizers and anammox were detected with significant relative abundances in the biofilm carriers used in the anoxic and aerobic compartments using 16S rRNA gene amplicon sequencing analysis. Therefore, the use of an IFAS system could be suited to diminish greenhouse gas emissions and nutrients concentration for those sewage treatment plants that used UASB systems, especially in countries with temperate and warm climates.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Modified integrated fixed-film activated sludge process: Advanced nitrogen removal for low-C/N domestic wastewater
    Liang, Zixuan
    Han, Hongbo
    Yi, Jing
    Dai, Xiaohu
    CHEMOSPHERE, 2022, 307
  • [42] Enhancing activated sludge nitrification through seeding from a downstream nitrifying fixed-film reactor
    Department of Agricultural Chemcial Technology, Budapest University of Technology and Ecomonics, Szt. Gellért tér 4, H-1111 Budapest, Hungary
    不详
    Period. Polytech. Chem. Eng., 2007, 1 (33-37): : 33 - 37
  • [43] Performance and microbial characteristics of integrated fixed-film activated sludge system treating industrial wastewater
    Li, C.
    Li, X. L.
    Ji, M.
    Liu, J.
    WATER SCIENCE AND TECHNOLOGY, 2012, 66 (12) : 2785 - 2792
  • [44] Effects of dissolved oxygen on biological nitrogen removal in Integrated Fixed Film Activated Sludge (IFAS) wastewater treatment process
    Sriwiriyarat, Tongchai
    Ungkurarate, Wiyaporn
    Fongsatitkul, Prayoon
    Chinwetkitvanich, Sopa
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2008, 43 (05): : 518 - 527
  • [45] Analysis of biohydrogen production from palm oil mill effluent using a pilot-scale up-flow anaerobic sludge blanket fixed-film reactor in life cycle perspective
    Akhbari, Azam
    Onn, Chiu Chuen
    Ibrahim, Shaliza
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (68) : 34059 - 34072
  • [46] Enhancing anaerobic digestion in anaerobic integrated floating fixed-film activated sludge (An-IFFAS) system using novel electron mediator suspended biofilm carriers
    Liu, Jifu
    Liu, Tao
    Chen, Shuo
    Yu, Hongtao
    Zhang, Yaobin
    Quan, Xie
    WATER RESEARCH, 2020, 175 (175)
  • [47] Biodegradation and nutrients removal from greywater by an integrated fixed-film activated sludge (IFAS) in different organic loadings rates
    Eslami, Hadi
    Ehrampoush, Mohammad Hassan
    Falahzadeh, Hossein
    Hematabadi, Parvaneh Talebi
    Khosravi, Rasoul
    Dalvand, Arash
    Esmaeili, Abbas
    Taghavi, Mahmoud
    Ebrahimi, Ali Asghar
    AMB EXPRESS, 2018, 8
  • [48] Biodegradation and nutrients removal from greywater by an integrated fixed-film activated sludge (IFAS) in different organic loadings rates
    Hadi Eslami
    Mohammad Hassan Ehrampoush
    Hossein Falahzadeh
    Parvaneh Talebi Hematabadi
    Rasoul Khosravi
    Arash Dalvand
    Abbas Esmaeili
    Mahmoud Taghavi
    Ali Asghar Ebrahimi
    AMB Express, 8
  • [49] Research progress of anaerobic ammonium oxidation (Anammox) process based on integrated fixed-film activated sludge (IFAS)
    Li, Guang
    Yu, Yunyong
    Li, Xingyu
    Jia, Hongsheng
    Ma, Xiaoning
    Opoku, Prince Atta
    ENVIRONMENTAL MICROBIOLOGY REPORTS, 2024, 16 (02):
  • [50] Simultaneous bioenergy (CH4) production and nitrogen removal in a combined upflow anaerobic sludge blanket and aerobic membrane bioreactor
    An, Yingyu
    Yang, Fenglin
    Wong, Fook Sin
    Chua, Hwee Chuan
    ENERGY & FUELS, 2008, 22 (01) : 103 - 107