Comparison of Commercial Test Kits for Detection of Salmonella and E. coli O157:H7 in Alfalfa Spent Sprout Irrigation Water

被引:1
作者
Fu, Tong-Jen [1 ]
Maks, Nicole [2 ]
Shazer, Arlette G. [1 ]
Chrysogelos, Christina [1 ]
机构
[1] US FDA, Div Food Proc Sci & Technol, 6502 South Archer Rd, Bedford Pk, IL 60501 USA
[2] IIT, Inst Food Safety & Hlth, 6502 South Archer Rd, Bedford Pk, IL 60501 USA
关键词
ESCHERICHIA-COLI; PATHOGEN DETECTION; MOLECULAR-DETECTION; RAPID DETECTION; CULTURE METHOD; GROUND-BEEF; FOODS; ENRICHMENT; VALIDATION; O157-H7;
D O I
10.1093/jaoacint/qsac008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Sprout growers in the United States are required to test spent sprout irrigation water (SSIW) or in-process sprouts for Escherichia coli O157:H7 and Salmonella species. Pathogen screening kits are commercially available; however, few have been validated for analysis of sprouts or SSIW. Objective This study evaluated AOAC-certified test kits (lateral flow devices [LFDs], enzyme immunoassays [EIAs], and molecular assays) in comparison with culture methods described in the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) for detection of Salmonella and E. coli O157:H7 in alfalfa SSIW. Method Twenty-five milliliter aliquots of alfalfa SSIW, either uninoculated or inoculated with Salmonella or E. coli O157:H7 at a low (similar to 0.5-0.7 CFU/25 mL) or high level (similar to 10-20 CFU/25 mL), were subjected to the enrichment and assay protocols recommended by each test. Pathogen presence was confirmed following FDA BAM procedures and, if applicable, test kit manufacturer protocols. Results Twelve of the 13 Salmonella test kits evaluated (except VIDAS UP) performed well and detected Salmonella in 100% of SSIW samples contaminated at 0.61 CFU/mL. Performance varied among E. coli O157:H7 test kits, with four (Reveal, MicroSEQ, GDS, MDA) of 12 kits designed for next-day detection, and four (Reveal, VIP Gold, MicroSEQ, GDS) of seven kits designed for same-day detection capable of detecting the pathogen in 100% samples contaminated at 0.90 CFU/mL. Conclusions Enrichment conditions play a key role in determining the performance of test kits and the success of confirmation.
引用
收藏
页码:1092 / 1104
页数:13
相关论文
共 50 条
  • [21] Detection of E. coli O157:H7 using its endogenous active membrane peroxidase
    Shim K.H.
    Kang M.
    Kim M.G.
    Chung B.H.
    An S.S.A.
    Toxicology and Environmental Health Sciences, 2011, 3 (2) : 80 - 85
  • [22] Aptamer-based SERS biosensor for whole cell analytical detection of E. coli O157:H7
    Diaz-Amaya, Susana
    Lin, Li-Kai
    Deering, Amanda J.
    Stanciu, Lia A.
    ANALYTICA CHIMICA ACTA, 2019, 1081 : 146 - 156
  • [23] Trace Detection of E. coli O157:H7 Cells by an Au Nanoparticle- Based SERS Aptasensor
    Tian, Cheng
    Zhao, Lei
    Qi, Guoliang
    Zhang, Shusheng
    ACS APPLIED NANO MATERIALS, 2023, 6 (02) : 1386 - 1394
  • [24] Inhibition of Beef Isolates of E. coli O157:H7 by Orange Oil at Various Temperatures
    Pendleton, Sean J.
    Crandall, Philip G.
    Ricke, Steven C.
    Goodridge, Lawrence
    O'Bryan, Corliss A.
    JOURNAL OF FOOD SCIENCE, 2012, 77 (06) : M308 - M311
  • [25] Evaluation of post-contamination survival and persistence of applied attenuated E. coli O157:H7 and naturally-contaminating E. coli O157:H7 on spinach under field conditions and following postharvest handling
    Gutierrez-Rodriguez, Eduardo
    Gundersen, Amy
    Sbodio, Adrian
    Koike, Steven
    Suslow, Trevor, V
    FOOD MICROBIOLOGY, 2019, 77 : 173 - 184
  • [26] Simultaneous detection of Salmonella spp and Escherichia coli O157:H7 by multiplex PCR
    Fratamico, PM
    Strobaugh, TP
    JOURNAL OF INDUSTRIAL MICROBIOLOGY & BIOTECHNOLOGY, 1998, 21 (03) : 92 - 98
  • [27] Novel Biosensor Based on Electrospun Nanofiber and Magnetic Nanoparticles for the Detection of E. coli O157:H7
    Luo, Yilun
    Nartker, Steven
    Wiederoder, Michael
    Miller, Hanna
    Hochhalter, David
    Drzal, Lawrence T.
    Alocilja, Evangelyn C.
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2012, 11 (04) : 676 - 681
  • [28] A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7
    Sobhan, Abdus
    Jia, Fei
    Kelso, Lisa Cooney
    Biswas, Sonatan Kumar
    Muthukumarappan, Kasiviswanathan
    Cao, Changyong
    Wei, Lin
    Li, Yanbin
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [29] Characterization and Antibiotic Resistance Profile of E. coli O157:H7 Isolates in Water Buffalo Carcasses
    Inac, Servet
    Gucukoglu, Ali
    EGYPTIAN JOURNAL OF VETERINARY SCIENCE, 2023, 54 (04): : 689 - 702
  • [30] Label free polyaniline based impedimetric biosensor for detection of E. coli O157:H7 Bacteria
    Chowdhury, Ankan Dutta
    De, Amitabha
    Chaudhuri, Chirosree Roy
    Bandyopadhyay, Krishnan
    Sen, Pintu
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 916 - 923