Comparison of Commercial Test Kits for Detection of Salmonella and E. coli O157:H7 in Alfalfa Spent Sprout Irrigation Water

被引:1
作者
Fu, Tong-Jen [1 ]
Maks, Nicole [2 ]
Shazer, Arlette G. [1 ]
Chrysogelos, Christina [1 ]
机构
[1] US FDA, Div Food Proc Sci & Technol, 6502 South Archer Rd, Bedford Pk, IL 60501 USA
[2] IIT, Inst Food Safety & Hlth, 6502 South Archer Rd, Bedford Pk, IL 60501 USA
关键词
ESCHERICHIA-COLI; PATHOGEN DETECTION; MOLECULAR-DETECTION; RAPID DETECTION; CULTURE METHOD; GROUND-BEEF; FOODS; ENRICHMENT; VALIDATION; O157-H7;
D O I
10.1093/jaoacint/qsac008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Sprout growers in the United States are required to test spent sprout irrigation water (SSIW) or in-process sprouts for Escherichia coli O157:H7 and Salmonella species. Pathogen screening kits are commercially available; however, few have been validated for analysis of sprouts or SSIW. Objective This study evaluated AOAC-certified test kits (lateral flow devices [LFDs], enzyme immunoassays [EIAs], and molecular assays) in comparison with culture methods described in the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) for detection of Salmonella and E. coli O157:H7 in alfalfa SSIW. Method Twenty-five milliliter aliquots of alfalfa SSIW, either uninoculated or inoculated with Salmonella or E. coli O157:H7 at a low (similar to 0.5-0.7 CFU/25 mL) or high level (similar to 10-20 CFU/25 mL), were subjected to the enrichment and assay protocols recommended by each test. Pathogen presence was confirmed following FDA BAM procedures and, if applicable, test kit manufacturer protocols. Results Twelve of the 13 Salmonella test kits evaluated (except VIDAS UP) performed well and detected Salmonella in 100% of SSIW samples contaminated at 0.61 CFU/mL. Performance varied among E. coli O157:H7 test kits, with four (Reveal, MicroSEQ, GDS, MDA) of 12 kits designed for next-day detection, and four (Reveal, VIP Gold, MicroSEQ, GDS) of seven kits designed for same-day detection capable of detecting the pathogen in 100% samples contaminated at 0.90 CFU/mL. Conclusions Enrichment conditions play a key role in determining the performance of test kits and the success of confirmation.
引用
收藏
页码:1092 / 1104
页数:13
相关论文
共 50 条
  • [1] Validation of the ANSR® E. coli O157:H7 Method for Detection of E. coli O157:H7
    Viator, Ryan
    Alles, Susan
    Le, Quynh-Nhi
    Hosking, Edan
    Meister, Evan
    Pinkava, Lisa
    Tovar, Eric
    Mozola, Mark
    Rice, Jennifer
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 705 - 716
  • [2] Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples
    Mishra, Kundan Kumar
    Dhamu, Vikram Narayanan
    Jophy, Chesna
    Muthukumar, Sriram
    Prasad, Shalini
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [3] Application of Immunomagnetic Separation to E. coli O157: H7 Detection
    Tang Qian-qian
    Wang Jian-ping
    Ye Zun-zhong
    Gai Ling
    Ying Yi-bin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2614 - 2618
  • [4] Detection of E. coli O157:H7 by immunomagnetic separation coupled with fluorescence immunoassay
    Zhu, Peixuan
    Shelton, Daniel R.
    Li, Shuhong
    Adams, Daniel L.
    Karns, Jeffrey S.
    Amstutz, Platte
    Tang, Cha-Mei
    BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) : 337 - 341
  • [5] Internalization of E. coli O157:H7 and Salmonella spp. in plants: A review
    Deering, Amanda J.
    Mauer, Lisa J.
    Pruitt, Robert E.
    FOOD RESEARCH INTERNATIONAL, 2012, 45 (02) : 567 - 575
  • [6] Sharp Transition in the Immunoimmobilization of E. coli O157:H7
    Celikkol-Aydin, Sukriye
    Suo, Zhiyong
    Yang, Xinghong
    Ince, Bahar
    Avci, Recep
    LANGMUIR, 2014, 30 (26) : 7755 - 7761
  • [7] A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection
    Abu Bakar, M. H.
    Ibrahim, M. H.
    Kassim, N. M.
    Mohammad, A. B.
    2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 2009, : 51 - 54
  • [8] Indirect immunofluorescence detection of E. coli O157:H7 with fluorescent silica nanoparticles
    Chen, Ze-Zhong
    Cai, Li
    Chen, Min-Yan
    Lin, Yi
    Pang, Dai-Wen
    Tang, Hong-Wu
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 95 - 102
  • [9] CURING THE DRUG RESISTANCE PLASMID IN E. COLI O157:H7
    Ozdemir, K.
    APPLIED ECOLOGY AND ENVIRONMENTAL RESEARCH, 2019, 17 (06): : 14715 - 14727
  • [10] A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7
    Dastider, Shibajyoti Ghosh
    Barizuddin, Syed
    Dweik, Majed
    Almasri, Mahmoud
    RSC ADVANCES, 2013, 3 (48): : 26297 - 26306