A simple determination of trace mercury concentrations in natural waters using dispersive Micro-Solid phase extraction preconcentration based on functionalized graphene nanosheets

被引:26
|
作者
Duval, Bastien [1 ,2 ,3 ]
Gredilla, Ainara [4 ]
Fdez-Ortiz de Vallejuelo, Silvia [1 ]
Tessier, Emmanuel [3 ]
Amouroux, David [3 ]
de Diego, Alberto [1 ,2 ]
机构
[1] Univ Basque Country, Dept Analyt Chem, Leioa 48940, Basque Country, Spain
[2] Univ Basque Country, PiE, UPV EHU, Plentzia Marine Stn, Plentzia Bizkaia 48620, Basque Country, Spain
[3] Univ Pau & Pays Adour, IPREM, E2S UPPA, CNRS,UMR 5254, F-64000 Pau, France
[4] Univ Basque Country, Fac Chem, Dept Appl Chem, UPV EHU, Manuel de Lardissabal Pasealekua 3, Donostia San Sebastian 20018, Basque Country, Spain
关键词
Mercury; Preconcentration; Ultra-trace analysis; Graphene nanosheets; Dispersive Micro-Solid Phase Extraction (DMSPE); Water Sample; DISSOLVED ORGANIC-MATTER; RAY-FLUORESCENCE SPECTROMETRY; ORGANOMETALLIC COMPOUNDS; ISOCHRONOUS STABILITY; GAS-CHROMATOGRAPHY; CARBON NANOTUBES; RISK-ASSESSMENT; ADSORPTION; SORBENT; METHYLMERCURY;
D O I
10.1016/j.microc.2019.104549
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we developed an innovative analytical method for the trace and ultra-trace determination of total mercury (Hg) concentration in natural water samples (fresh and seawaters). In this method, Dispersive Micro-Solid Phase Extraction (DMSPE) is applied using graphene nanosheets to quantitatively preconcentrate dissolved Hg from natural water samples, before its direct analysis by commercially available pyrolysis gold amalgamation and atomic absorption spectroscopy (AAS). In this new methodology, only two easy steps are necessary, saving time and effort. First, the operator has to add 500 mu L of nanoparticles suspension containing graphene, Ammonium Pyrrolidine DithioCarbamate (APDC) and Triton-X-100 in the water sample. This solution is filtered under vacuum and the Hg complex on the functionalized graphene can be simply collected on a membrane filter (Polyethersulfone PES, 0.2 mu m). The filter obtained can then be analysed back at the laboratory by direct pyrolysis of the PES filter using a commercial mercury analyser. Different parameters have been tested to optimize this preconcentration procedure, such as the sample volume, the amount of nanoparticles suspension and the extraction time. The stability conditions of the Hg preconcentrated on PES filters during storage and before analysis has also been investigated. The influence of the occurrence of marine salts (sodium chloride), natural organic matter or competing metals (calcium) in the sample has also been evaluated to prevent possible matrix effects. This method is fully operational after application to real water sample matrices and exhibits suitable limit of detection, as low as 0.38 ng L-1 using 200 mL of the water sample, and excellent reproducibility (< 5% as RSD).
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Micro-solid phase extraction of chlorophenols using reduced graphene oxide functionalized with magnetic nanoparticles and graphitic carbon nitride as the adsorbent
    Zang, Xiaohuan
    Chang, Qingyun
    Liang, Weiqian
    Wu, Tong
    Wang, Chun
    Wang, Zhi
    MICROCHIMICA ACTA, 2018, 185 (01)
  • [32] Micro-solid phase extraction of ochratoxin A, and its determination in urine using capillary electrophoresis
    Tien Ping Lee
    Bahruddin Saad
    Baharuddin Salleh
    Ishak Mat
    Microchimica Acta, 2013, 180 : 1149 - 1156
  • [33] Solid phase extraction of trace amount of mercury from natural waters on silver and gold nanoparticles
    Panichev, N.
    Kalumba, M. M.
    Mandiwana, K. L.
    ANALYTICA CHIMICA ACTA, 2014, 813 : 56 - 62
  • [34] Solid phase extraction of trace amount of mercury from natural waters on silver and gold nanoparticles
    Kalumba, M.M. (Kalumba.merime1@gmail.com), 1600, Elsevier B.V., Netherlands (813):
  • [35] An innovative chemometric approach for simultaneous determination of polycyclic aromatic hydrocarbons in oil-contaminated waters based on dispersive micro-solid phase extraction followed by gas chromatography
    Saburouh, Nazanin
    Jabbari, Ali
    Parastar, Hadi
    MICROCHEMICAL JOURNAL, 2020, 159
  • [36] Deep Eutectic Solvent Micro-Functionalized Graphene Assisted Dispersive Micro Solid-Phase Extraction of Pyrethroid Insecticides in Natural Products
    Song, Xiaoyu
    Zhang, Rui
    Xie, Tian
    Wang, Shuling
    Cao, Jun
    FRONTIERS IN CHEMISTRY, 2019, 7
  • [37] The dispersive micro-solid phase extraction method for MS-based lipidomics of human breast milk
    Bakhytkyzy, Inal
    Hewelt-Belka, Weronika
    Kot-Wasik, Agata
    MICROCHEMICAL JOURNAL, 2020, 152
  • [38] Micro-solid phase extraction of ochratoxin A, and its determination in urine using capillary electrophoresis
    Lee, Tien Ping
    Saad, Bahruddin
    Salleh, Baharuddin
    Mat, Ishak
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1149 - 1156
  • [39] An automated magnetic dispersive micro-solid phase extraction in a fluidized reactor for the determination of fluoroquinolones in baby food samples
    Vakh, Christina
    Alaboud, Marcel
    Lebedinets, Sofya
    Korolev, Dmitry
    Postnov, Viktor
    Moskvin, Leonid
    Osmolovskaya, Olga
    Bulatov, Andrey
    ANALYTICA CHIMICA ACTA, 2018, 1001 : 59 - 69
  • [40] In-syringe dispersive micro-solid phase extraction method for the HPLC-fluorescence determination of aflatoxins in milk
    Shuib, Nor Shifa
    Saad, Bahruddin
    FOOD CONTROL, 2022, 132