An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position

被引:15
作者
Tetsunaga, Tomonori [1 ]
Yamada, Kazuki [2 ]
Tetsunaga, Tomoko [1 ]
Sanki, Tomoaki [1 ]
Kawamura, Yoshi [1 ]
Ozaki, Toshifumi [1 ]
机构
[1] Okayama Univ Hosp, Dept Orthopaed Surg, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Med Mat Musculoskeletal Reconstruct, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
关键词
Hip; Navigation system; Total hip replacement; Retrospective study; PELVIC TILT; SAFE ZONE; COMPONENT; REPLACEMENT; INCLINATION; DISLOCATION; RANGE; WEAR;
D O I
10.1186/s13018-020-01673-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Inadequate acetabular component orientation is associated with postoperative impingement, dislocation, and accelerated polyethylene wear. Computed tomography (CT)-based navigation systems provide accuracy for total hip arthroplasty (THA) but are not available in all facilities. Accelerometer-based navigation systems are inexpensive, but their accuracy remains undetermined. This study compares the accuracy of cup orientation in THA using CT-based and accelerometer-based navigation systems. Methods This retrospective study included 35 consecutive patients (11 males, 24 females; mean age, 65 years) who underwent primary cementless THA via an anterolateral approach in the supine position. Both CT-based and accelerometer-based navigation systems were used simultaneously. The accuracy of cup orientation was compared between the two systems using postoperative CT. Results The accuracy of cup inclination was 2.7 degrees +/- 2.0 degrees in the CT-based group and 3.3 degrees +/- 2.4 degrees in the accelerometer-based group. The accuracy of cup anteversion was 2.8 degrees +/- 2.6 degrees in the CT-based group and 3.4 degrees +/- 2.2 degrees in the accelerometer-based group. No significant difference was observed in cup inclination (p = 0.29) or cup anteversion (p = 0.34) between CT-based and accelerometer-based navigation. Conclusions The accuracy of cup positioning did not differ significantly between CT-based and accelerometer-based navigation systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device
    Nakasone, Satoshi
    Takaesu, Mika
    Ishihara, Masato
    Onaga, Masamichi
    Igei, Takahiro
    Miyata, Yoshihide
    Nishida, Kotaro
    ARTHROPLASTY TODAY, 2022, 16 : 46 - 52
  • [42] Accurate cup placement using a portable navigation system during total hip arthroplasty based on pelvic orientation in the lateral decubitus position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Uchida, Soshi
    Sakai, Akinori
    ARTIFICIAL ORGANS, 2022, 46 (12) : 2412 - 2422
  • [43] How Much Does a Computed Tomography-Based Mixed-Reality Navigation System Change Freehand Acetabular Component Position?
    Leal, Justin
    Heimann, Alexander F.
    Dilbone, Eric S.
    Ryan, Sean P.
    Wellman, Samuel S.
    ARTHROPLASTY TODAY, 2025, 32
  • [44] Isolated acetabular revision with femoral stem retention using computed tomography-based navigation
    Kubota, Yuta
    Kaku, Nobuhiro
    Tagomori, Hiroaki
    Kataoka, Masashi
    Tsumura, Hiroshi
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (07) : 1311 - 1317
  • [45] Evaluation of the Accuracy of Computed Tomography-Based Navigation for Femoral Stem Orientation and Leg Length Discrepancy
    Kitada, Makoto
    Nakamura, Nobuo
    Iwana, Daiki
    Kakimoto, Akihiro
    Nishii, Takashi
    Sugano, Nobuhiko
    JOURNAL OF ARTHROPLASTY, 2011, 26 (05) : 674 - 679
  • [46] Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study
    Kiyohara, Masato
    Hamai, Satoshi
    Shiomoto, Kyohei
    Harada, Satoru
    Harada, Tetsunari
    Motomura, Goro
    Ikemura, Satoshi
    Fujii, Masanori
    Kawahara, Shinya
    Nakashima, Yasuharu
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (06) : 1007 - 1015
  • [47] Trends in cup position utilizing computer-assisted navigation during total hip arthroplasty: A retrospective observational study
    Mays, Rachel R.
    Benson, Jessica R.
    Muir, Jeffrey M.
    Meftah, Morteza
    CURRENT ORTHOPAEDIC PRACTICE, 2020, 31 (03): : 211 - 217
  • [48] Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia
    Kaku, Nobuhiro
    Tagomori, Hiroaki
    Tsumura, Hiroshi
    CLINICS IN ORTHOPEDIC SURGERY, 2021, 13 (02) : 144 - 151
  • [49] The Accuracy of Cup Placement in Total Hip Arthroplasty (THA) Using an Augmented Reality-Based Navigation System
    Shimizu, Junya
    Nagoya, Satoshi
    Kosukegawa, Ima
    Kanaizumi, Arata
    Nakahashi, Naoya
    Teramoto, Atsushi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [50] Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study
    Yamada, Kazuki
    Endo, Hirosuke
    Tetsunaga, Tomonori
    Miyake, Takamasa
    Sanki, Tomoaki
    Ozaki, Toshifumi
    JOURNAL OF ARTHROPLASTY, 2018, 33 (01) : 136 - 143