An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position

被引:15
作者
Tetsunaga, Tomonori [1 ]
Yamada, Kazuki [2 ]
Tetsunaga, Tomoko [1 ]
Sanki, Tomoaki [1 ]
Kawamura, Yoshi [1 ]
Ozaki, Toshifumi [1 ]
机构
[1] Okayama Univ Hosp, Dept Orthopaed Surg, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Med Mat Musculoskeletal Reconstruct, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
关键词
Hip; Navigation system; Total hip replacement; Retrospective study; PELVIC TILT; SAFE ZONE; COMPONENT; REPLACEMENT; INCLINATION; DISLOCATION; RANGE; WEAR;
D O I
10.1186/s13018-020-01673-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Inadequate acetabular component orientation is associated with postoperative impingement, dislocation, and accelerated polyethylene wear. Computed tomography (CT)-based navigation systems provide accuracy for total hip arthroplasty (THA) but are not available in all facilities. Accelerometer-based navigation systems are inexpensive, but their accuracy remains undetermined. This study compares the accuracy of cup orientation in THA using CT-based and accelerometer-based navigation systems. Methods This retrospective study included 35 consecutive patients (11 males, 24 females; mean age, 65 years) who underwent primary cementless THA via an anterolateral approach in the supine position. Both CT-based and accelerometer-based navigation systems were used simultaneously. The accuracy of cup orientation was compared between the two systems using postoperative CT. Results The accuracy of cup inclination was 2.7 degrees +/- 2.0 degrees in the CT-based group and 3.3 degrees +/- 2.4 degrees in the accelerometer-based group. The accuracy of cup anteversion was 2.8 degrees +/- 2.6 degrees in the CT-based group and 3.4 degrees +/- 2.2 degrees in the accelerometer-based group. No significant difference was observed in cup inclination (p = 0.29) or cup anteversion (p = 0.34) between CT-based and accelerometer-based navigation. Conclusions The accuracy of cup positioning did not differ significantly between CT-based and accelerometer-based navigation systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Precision of Cup Positioning Using a Novel Computed Tomography Based Navigation System in Total Hip Arthroplasty
    Nemati, Hassan M.
    Christensson, Albin
    Pettersson, Andreas
    Nemeth, Gunnar
    Flivik, Gunnar
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [32] The value of computed tomography based navigation in revision total hip arthroplasty
    Kuroda, Kazunari
    Kabata, Tamon
    Maeda, Toru
    Kajino, Yoshitomo
    Watanabe, Shin
    Iwai, Shintaro
    Kenji, Fujita
    Hasegawa, Kazuhiro
    Inoue, Daisuke
    Tsuchiya, Hiroyuki
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 711 - 716
  • [33] Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty
    Huang, Eddie H.
    Copp, Steven N.
    Bugbee, William D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (11) : 1906 - 1910
  • [34] Accuracy of leg length changes in total hip arthroplasty using a computed tomography-based augmented reality navigation system
    Kobayashi, Gai
    Ichikawa, Shintaro
    Tone, Shine
    Naito, Yohei
    Sudo, Akihiro
    Hasegawa, Masahiro
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 145 (01)
  • [35] Usefulness of an accelerometer-based portable navigation system in total knee arthroplasty
    Ikawa, T.
    Takemura, S.
    Kim, M.
    Takaoka, K.
    Minoda, Y.
    Kadoya, Y.
    BONE & JOINT JOURNAL, 2017, 99B (08) : 1047 - 1052
  • [36] Is a portable accelerometer-based navigation system useful in total hip arthroplasty?: A systematic review and meta-analysis
    Shigemura, Tomonori
    Baba, Yoshihiko
    Murata, Yasuaki
    Yamamoto, Yohei
    Shiratani, Yuki
    Hamano, Hiroyuki
    Wada, Yuichi
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)
  • [37] Accuracy of computer navigation in total knee arthroplasty: A prospective computed tomography-based study
    Hannan, Richard
    Free, Matthew
    Arora, Varun
    Harle, Robin
    Harvie, Paul
    MEDICAL ENGINEERING & PHYSICS, 2020, 79 : 52 - 59
  • [38] Does Degree of the Pelvic Deformity Affect the Accuracy of Computed Tomography-Based Hip Navigation?
    Kajino, Yoshitomo
    Kabata, Tamon
    Maeda, Toru
    Iwai, Shintaro
    Kuroda, Kazunari
    Tsuchiya, Hiroyuki
    JOURNAL OF ARTHROPLASTY, 2012, 27 (09) : 1651 - 1657
  • [39] Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis
    Miyasaka, Teruyuki
    Kurosaka, Daisaburo
    Saito, Mitsuru
    Omori, Toshiyuki
    Ikeda, Ryo
    Marumo, Keishi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01) : 47 - 52
  • [40] Improvement of activities of daily living after total hip arthroplasty using a computed tomography-based navigation system
    Maeda, Yuki
    Nakamura, Nobuo
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (02) : 152 - 157