An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position

被引:15
作者
Tetsunaga, Tomonori [1 ]
Yamada, Kazuki [2 ]
Tetsunaga, Tomoko [1 ]
Sanki, Tomoaki [1 ]
Kawamura, Yoshi [1 ]
Ozaki, Toshifumi [1 ]
机构
[1] Okayama Univ Hosp, Dept Orthopaed Surg, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Med Mat Musculoskeletal Reconstruct, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
关键词
Hip; Navigation system; Total hip replacement; Retrospective study; PELVIC TILT; SAFE ZONE; COMPONENT; REPLACEMENT; INCLINATION; DISLOCATION; RANGE; WEAR;
D O I
10.1186/s13018-020-01673-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Inadequate acetabular component orientation is associated with postoperative impingement, dislocation, and accelerated polyethylene wear. Computed tomography (CT)-based navigation systems provide accuracy for total hip arthroplasty (THA) but are not available in all facilities. Accelerometer-based navigation systems are inexpensive, but their accuracy remains undetermined. This study compares the accuracy of cup orientation in THA using CT-based and accelerometer-based navigation systems. Methods This retrospective study included 35 consecutive patients (11 males, 24 females; mean age, 65 years) who underwent primary cementless THA via an anterolateral approach in the supine position. Both CT-based and accelerometer-based navigation systems were used simultaneously. The accuracy of cup orientation was compared between the two systems using postoperative CT. Results The accuracy of cup inclination was 2.7 degrees +/- 2.0 degrees in the CT-based group and 3.3 degrees +/- 2.4 degrees in the accelerometer-based group. The accuracy of cup anteversion was 2.8 degrees +/- 2.6 degrees in the CT-based group and 3.4 degrees +/- 2.2 degrees in the accelerometer-based group. No significant difference was observed in cup inclination (p = 0.29) or cup anteversion (p = 0.34) between CT-based and accelerometer-based navigation. Conclusions The accuracy of cup positioning did not differ significantly between CT-based and accelerometer-based navigation systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The Accuracy of the Computed Tomography-Based Navigation System in Total Hip Arthroplasty Is Comparable With Crowe Type IV and Crowe Type I Dysplasia: A Case-Control Study
    Ueoka, Ken
    Kabata, Tamon
    Kajino, Yoshitomo
    Yoshitani, Junya
    Ueno, Takuro
    Tsuchiya, Hiroyuki
    JOURNAL OF ARTHROPLASTY, 2019, 34 (11) : 2686 - 2691
  • [22] Portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position
    Takada, Ryohei
    Jinno, Tetsuya
    Miyatake, Kazumasa
    Hirao, Masanobu
    Yoshii, Toshitaka
    Okawa, Atsushi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (04) : 707 - 712
  • [23] Postsurgical infection from using a computed tomography-based hip navigation system during total hip arthroplasty
    Inoue, Daisuke
    Kabata, Tamon
    Kajino, Yoshitomo
    Ohmori, Takaaki
    Ueno, Takuro
    Taga, Tadashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueoka, Ken
    Yamamuro, Yuuki
    Tsuchiya, Hiroyuki
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (06) : 1097 - 1101
  • [24] Combined Anteversion Technique for Total Hip Arthroplasty With Handheld Accelerometer-Based Navigation System
    Perico, Diego Alarcon
    Warne, Christopher N.
    Lee, Sheng-Hsun
    Roberts, Heather J.
    Sierra, Rafael J.
    ARTHROPLASTY TODAY, 2023, 23
  • [25] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [26] Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position
    Okamoto, Masanori
    Kawasaki, Masashi
    Okura, Toshiaki
    Ochiai, Satoshi
    Yokoi, Hiroyuki
    HIP INTERNATIONAL, 2021, 31 (04) : 492 - 499
  • [27] Relationship between the Accuracy of the Acetabular Cup Angle and BMI in Posterolateral Total Hip Arthroplasty with CT-Based Navigation
    Ishikura, Hisatoshi
    Nakamura, Masaki
    Nakamura, Shigeru
    Tanaka, Takeyuki
    Kawano, Hirotaka
    Tanaka, Sakae
    MEDICINA-LITHUANIA, 2022, 58 (07):
  • [28] Robotic Arm-Assisted System Improved Accuracy of Cup Position and Orientation in Cementless Total Hip Arthroplasty for Dysplastic Hips: A Comparison Among Groups With Manual Placement, Computed Tomography-Based Navigation, and Robotic Surgery
    Konishi, Toshiki
    Sato, Taishi
    Hamai, Satoshi
    Kawahara, Shinya
    Hara, Daisuke
    Nakashima, Yasuharu
    ARTHROPLASTY TODAY, 2024, 28
  • [29] Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study
    Tanino, Hiromasa
    Nishida, Yasuhiro
    Mitsutake, Ryo
    Ito, Hiroshi
    JOURNAL OF ARTHROPLASTY, 2020, 35 (01) : 172 - 177
  • [30] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)