Fourier-Domain OCT in Multiple Sclerosis Patients: Reproducibility and Ability to Detect Retinal Nerve Fiber Layer Atrophy

被引:60
作者
Garcia-Martin, Elena [1 ,3 ]
Pueyo, Victoria [1 ,3 ]
Pinilla, Isabel [1 ,3 ]
Ara, Jose-Ramon [2 ]
Martin, Jesus [2 ]
Fernandez, Javier [1 ]
机构
[1] Miguel Servet Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
[2] Miguel Servet Univ Hosp, Dept Neurol, Zaragoza, Spain
[3] Aragones Inst Hlth Sci, Zaragoza, Spain
关键词
OPTICAL COHERENCE TOMOGRAPHY; CIRRUS HD-OCT; THICKNESS MEASUREMENTS; SPECTRAL-DOMAIN; GLAUCOMATOUS EYES; TIME-DOMAIN; LASER POLARIMETRY; STRATUS OCT; VARIABILITY; ACCURACY;
D O I
10.1167/iovs.10-6643
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the ability of Fourier-domain (FD) optical coherence tomography (OCT) to detect retinal nerve fiber layer (RNFL) atrophy in multiple sclerosis (MS) patients. To test the intrasession reproducibility of RNFL thickness measurements in MS and healthy subjects using Cirrus (Carl Zeiss Meditec, Dublin, CA) and Spectralis (Heidelberg Engineering, Heidelberg, Germany) OCT. METHODS. Two hundred twenty-two eyes of 111 subjects (50 MS patients and 61 healthy subjects) underwent three 360 degrees circular scans centered on the optic disc by the same experienced examiner using the Cirrus and Spectralis OCT instruments. Differences between healthy and MS eyes were compared. The relationship between average thicknesses with each OCT was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation (COV). RESULTS. RNFL atrophy was detected in the MS eyes for all OCT parameters (P < 0.05). Cirrus and Spectralis showed an RNFL average thickness of 99.4 and 102.5 mu m, respectively, in healthy subjects, and 86.0 and 90.4 mu m in the MS eyes. RNFL average thickness in the MS eyes determined by both OCTs correlated (r = 0.812; P < 0.001), but were significantly different (P < 0.001). Reproducibility was good. In the MS eyes, Cirrus measurements showed a mean COV of 5.85%, Spectralis 6.80%, and Spectralis with a progression feature 4.16%. Intraclass correlation coefficients were higher than 0.840. RNFL average thickness correlated with disease duration and an optic neuritis antecedent. CONCLUSIONS. There are significant differences in RNFL thickness measurements between Cirrus and Spectralis despite a high correlation of measurement between the two instruments. Fourier-domain OCT can be considered a valid device for detecting RNFL atrophy in MS patients. (Invest Ophthalmol Vis Sci. 2011; 52:4124-4131) DOI:10.1167/iovs.10-6643
引用
收藏
页码:4124 / 4131
页数:8
相关论文
共 41 条
  • [1] Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
    Blumenthal, EZ
    Williams, JM
    Weinreb, RN
    Girkin, CA
    Berry, CC
    Zangwill, LM
    [J]. OPHTHALMOLOGY, 2000, 107 (12) : 2278 - 2282
  • [2] Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    Budenz, DL
    Chang, RT
    Huang, XR
    Knighton, RW
    Tielsch, JM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2440 - 2443
  • [3] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Detection of Band Atrophy of the Optic Nerve
    Costa-Cunha, Luciana V. F.
    Cunha, Leonardo P.
    Malta, Roberto F. S.
    Monteiro, Mario L. R.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (01) : 56 - 63
  • [4] Quantifying tonal loss after optic neuritis with optical coherence tomography
    Costello, F
    Coupland, S
    Hodge, W
    Lorello, GR
    Koroluk, J
    Pan, YI
    Freedman, MS
    Zackon, DH
    Kardon, RH
    [J]. ANNALS OF NEUROLOGY, 2006, 59 (06) : 963 - 969
  • [5] Fourier analysis of optical coherence tomography and scanning laser polarimetry retinal nerve fiber layer measurements in the diagnosis of glaucoma
    Essock, EA
    Sinai, MJ
    Bowd, C
    Zangwill, LM
    Weinreb, RN
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (09) : 1238 - 1245
  • [6] Relation of visual function to retinal nerve fiber layer thickness in multiple sclerosis
    Fisher, JB
    Jacobs, DA
    Markowitz, CE
    Galetta, SL
    Volpe, NJ
    Nano-Schiavi, ML
    Baier, ML
    Frohman, EM
    Winslow, H
    Frohman, TC
    Calabresi, PA
    Maguire, MG
    Cutter, GR
    Balcer, LJ
    [J]. OPHTHALMOLOGY, 2006, 113 (02) : 324 - 332
  • [7] Relative course of retinal nerve fiber layer birefringence and thickness and retinal function changes after optic nerve transection
    Fortune, Brad
    Cull, Grant A.
    Burgoyne, Claude F.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) : 4444 - 4452
  • [8] Relationship of optic nerve and brain conventional and non-conventional MRI measures and retinal nerve fiber layer thickness, as assessed by OCT and GDx: A pilot study
    Frohman, Elliot M.
    Dwyer, Michael G.
    Frohman, Teresa
    Cox, Jennifer L.
    Salter, Amber
    Greenberg, Benjamin M.
    Hussein, Sara
    Conger, Amy
    Calabresi, Peter
    Balcer, Laura J.
    Zivadinov, Robert
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2009, 282 (1-2) : 96 - 105
  • [9] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurement with the RTVue-100 Optical Coherence Tomograph
    Garas, Anita
    Vargha, Peter
    Hollo, Gabor
    [J]. OPHTHALMOLOGY, 2010, 117 (04) : 738 - 746
  • [10] Intra and interoperator reproducibility of retinal nerve fibre and macular thickness measurements using Cirrus Fourier-domain OCT
    Garcia-Martin, Elena
    Pinilla, Isabel
    Idoipe, Miriam
    Fuertes, Isabel
    Pueyo, Victoria
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E23 - E29