Accuracy of a prediction model for heparin-induced thrombocytopenia (HIT): An analysis based on individual patient data

被引:3
|
作者
Garcia Junqueira, Daniela Rezende [1 ]
Viana, Thercia Guedes [1 ]
Carvalho, Maria das Gracas [2 ]
Perini, Edson [1 ]
机构
[1] Univ Fed Minas Gerais, Ctr Drug Studies Cemed, Dept Social Pharm, Sch Pharm, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Dept Clin & Toxicol Anal, Sch Pharm, Belo Horizonte, MG, Brazil
关键词
Heparin; Adverse drug reaction; Diagnosis; Thrombocytopenia; Diagnostic test accuracy; Algorithm; OPERATING CHARACTERISTIC CURVES; DIAGNOSIS; ANTIBODIES; MANAGEMENT; ASSAY;
D O I
10.1016/j.cca.2011.04.026
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Heparin-induced thrombocytopenia (HIT) is an adverse drug reaction associated with thrombosis, and its paradoxical nature is a challenging issue for the diagnosis. The '4Ts' scoring system represents a simple and efficient way to improve clinical diagnoses of the syndrome. This system classifies patients as having high, intermediate, and low clinical probability for HIT. However, uncertainty remains concerning its clinical meaning, thus weakening the diagnostic value of this screening instrument. Methods: We analyzed the diagnostic test accuracy based on individual patient data extracted from published primary scientific studies. This study focused on 186 cases of treatment with heparin, which later evolved into a clinical suspicion of HIT. Upon choosing the most appropriate reference laboratory, the accuracy of the 4Ts was analyzed using the receiver operator characteristic curve analysis. Results: Half of the positive cases (57.1%) were classified as having a high score, while 25.5% of the negative cases were classified as a having low score for HIT. Slightly more than half of all patients (53.2%) were classified as having an intermediate score. As such, the pre-test instrument would most likely fail to distinguish between diseased and nondiseased patients in a relevant number of cases. The calculated accuracy of the summary indicates that the 4Ts can be considered a good, but not a defining, test. Conclusion: Further studies are warranted regarding clinical score systems, either alone or in combination with laboratory tests, in an attempt to improve the early diagnosis of this adverse drug reaction and to provide better care for at-risk patients. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1521 / 1526
页数:6
相关论文
共 50 条
  • [1] Heparin-induced thrombocytopenia: Recent data
    Gruel, Y.
    Rollin, J.
    Leroux, D.
    Pouplard, C.
    REVUE DE MEDECINE INTERNE, 2014, 35 (03): : 174 - 182
  • [2] Heparin-induced thrombocytopenia (HIT)
    Evans, Natalie S.
    Gomes, Marcelo
    VASCULAR MEDICINE, 2017, 22 (04) : 353 - 355
  • [3] Heparin-induced thrombocytopenia (HIT) in 2011: An epidemic of overdiagnosis
    Cuker, Adam
    THROMBOSIS AND HAEMOSTASIS, 2011, 106 (06) : 993 - 994
  • [4] Accuracy of the functional, flow cytometer-based Emo-Test HIT Confirm® for the diagnosis of heparin-induced thrombocytopenia
    Brodard, Justine
    Benites, Vincent
    Zeerleder, Denise Stalder
    Nagler, Michael
    THROMBOSIS RESEARCH, 2021, 203 : 22 - 26
  • [5] Heparin-induced thrombocytopenia type II (HIT II). A medical-economic view
    Riedel, R.
    Schmieder, A.
    Koster, A.
    Kim, S.
    Baumgarten, G.
    Schewe, J. C.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2017, 112 (04) : 334 - 346
  • [6] The impact of the heparin-induced thrombocytopenia (HIT) computerized alert on provider behaviors and patient outcomes
    Austrian, Jonathan S.
    Adelman, Jason S.
    Reissman, Stan H.
    Cohen, Hillel W.
    Billett, Henny H.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2011, 18 (06) : 783 - 788
  • [7] Performance characteristics of two commercially available IgG-specific immunoassays in the assessment of heparin-induced thrombocytopenia (HIT)
    Bakchoul, Tamam
    Giptner, Astrid
    Bein, Gregor
    Santoso, Sentot
    Sachs, Ulrich J. H.
    THROMBOSIS RESEARCH, 2011, 127 (04) : 345 - 348
  • [8] Pathogenic heparin-induced thrombocytopenia and thrombosis (HIT) antibodies determined by rapid functional flow cytometry
    Cipok, Michal
    Tomer, Aaron
    Elalamy, Ismail
    Kirgner, Ilya
    Dror, Naama
    Kay, Sigi
    Deutsch, Varda R.
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2019, 103 (03) : 225 - 233
  • [9] Heparin-induced thrombocytopenia: Impact of bovine versus porcine heparin in HIT pathogenesis
    Ahmad, Sarfraz
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2007, 12 : 3312 - 3320
  • [10] ET gets HIT - thrombocytotic heparin-induced thrombocytopenia (HIT) in a patient with essential thrombocythemia (ET)
    Risch, L
    Pihan, H
    Zeller, C
    Huber, AR
    BLOOD COAGULATION & FIBRINOLYSIS, 2000, 11 (07) : 663 - 667