Practical PET Respiratory Motion Correction in Clinical PET/MR

被引:64
作者
Manber, Richard [1 ]
Thielemans, Kris [2 ]
Hutton, Brian F. [2 ,3 ]
Barnes, Anna [2 ]
Ourselin, Sebastien [4 ]
Arridge, Simon [4 ]
O'Meara, Celia [5 ]
Wan, Simon [2 ]
Atkinson, David [1 ]
机构
[1] UCL, Ctr Med Imaging, Div Med, London, England
[2] UCL Hosp, Inst Nucl Med, London, England
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[4] Univ Coll London Hosp, Fac Engn, Ctr Med Imaging Comp, London NW1 2BU, England
[5] Sidra Med & Res Ctr, Doha, Qatar
基金
英国工程与自然科学研究理事会;
关键词
motion correction; PET/MR; lesion detection; lesion quantification; IMAGE-RECONSTRUCTION; MRI; LUNG;
D O I
10.2967/jnumed.114.151779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion during PET acquisition may lead to blurring in resulting images and underestimation of uptake parameters. The advent of integrated PET/MR scanners allows us to exploit the integration of modalities, using high spatial resolution and high-contrast MR images to monitor and correct PET images degraded by motion. We proposed a practical, anatomy-independent MR-based correction strategy for PET data affected by respiratory motion and showed that it can improve image quality both for PET acquired simultaneously to the motion-capturing MR and for PET acquired up to 1 h earlier during a clinical scan. Methods: To estimate the respiratory motion, our method needs only an extra 1-min dynamic MR scan, acquired at the end of the clinical PET/MR protocol. A respiratory signal was extracted directly from the PET list-mode data. This signal was used to gate the PET data and to construct a motion model built from the dynamic MR data. The estimated motion was then incorporated into the PET image reconstruction to obtain a single motion-corrected PET image. We evaluated our method in 2 steps. The PET-derived respiratory signal was compared with an MR measure of diaphragmatic displacement via a pencil-beam navigator. The motion-corrected images were compared with uncorrected images with visual inspection, line profiles, and standardized uptake value (SUV) in focally avid lesions. Results: We showed a strong correlation between the PET-derived and MR-derived respiratory signals for 9 patients, with a mean correlation of 0.89. We then showed 4 clinical case study examples (F-18-FDG and Ga-68-DOTATATE) using the motion-correction technique, demonstrating improvements in image sharpness and reduction of respiratory artifacts in scans containing pancreatic, liver, and lung lesions as well as cardiac scans. The mean increase in peak SUV (SUVpeak) and maximum SUV (SUVmax) in a patient with 4 pancreatic lesions was 23.1% and 34.5% in PET acquired simultaneously with motion-capturing MR, and 17.6% and 24.7% in PET acquired 50 min before as part of the clinical scan. Conclusion: We showed that a respiratory signal can be obtained from raw PET data and that the clinical PET image quality can be improved using only a short additional PET/MR acquisition. Our method does not need external respiratory hardware or modification of the normal clinical MR sequences.
引用
收藏
页码:890 / 896
页数:7
相关论文
共 50 条
  • [41] Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
    Petibon, Yoann
    Guehl, Nicolas J.
    Reese, Timothy G.
    Ebrahimi, Behzad
    Normandin, Marc D.
    Shoup, Timothy M.
    Alpert, Nathaniel M.
    El Fakhri, Georges
    Ouyang, Jinsong
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02) : 326 - 343
  • [42] Respiratory motion correction with an improved demons algorithm for PET images
    Gao Juan
    Chai Pei
    Yun Ming-Kai
    Liu Shuang-Quan
    Shan Bao-Ci
    Wei Long
    CHINESE PHYSICS C, 2012, 36 (10) : 1025 - 1030
  • [43] Attenuation correction for PET/MR: Problems, novel approaches and practical solutions
    Martinez-Moeller, Axel
    Nekolla, Stephan G.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (04): : 299 - 310
  • [44] Attenuation Correction of the Cerebellum in PET/MR Data
    Kops, Elena Rota
    Alrakh, Heba
    Brambilla, Claudia Regio
    Scheins, Jurgen
    Herzog, Hans
    Shah, N. Jon
    Lerche, Christoph
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (06) : 618 - 631
  • [45] Investigation of MR-Based Attenuation Correction and Motion Compensation for Hybrid PET/MR
    Buerger, Christian
    Tsoumpas, Charalampos
    Aitken, Andrew
    King, Andrew Peter
    Schleyer, Paul
    Schulz, Volkmar
    Marsden, Paul K.
    Schaeffter, Tobias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1967 - 1976
  • [46] Statistical evaluation of PET motion correction methods using MR derived motion fields
    Polycarpou, Irene
    Tsoumpas, Charalampos
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3579 - 3585
  • [47] Potential Clinical Applications of PET/MR
    Mader, Caecilia E.
    Fuchs, Tobias
    Ferraro, Daniela A.
    Burger, Irene A.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (03) : 293 - 299
  • [48] MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
    Petibon, Y.
    Sun, T.
    Han, P. K.
    Ma, C.
    El Fakhri, G.
    Ouyang, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19)
  • [49] Lung motion correction on respiratory gated 3-D PET/CT images
    Dawood, M
    Lang, N
    Jiang, XY
    Schäfers, KP
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) : 476 - 485
  • [50] Data-driven, projection-based respiratory motion compensation of PET data for cardiac PET/CT and PET/MR imaging
    Lassen, Martin Lyngby
    Beyer, Thomas
    Berger, Alexander
    Beitzke, Dietrich
    Rasul, Sazan
    Buether, Florian
    Hacker, Marcus
    Cal-Gonzalez, Jacobo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (06) : 2216 - 2230