Practical PET Respiratory Motion Correction in Clinical PET/MR

被引:64
作者
Manber, Richard [1 ]
Thielemans, Kris [2 ]
Hutton, Brian F. [2 ,3 ]
Barnes, Anna [2 ]
Ourselin, Sebastien [4 ]
Arridge, Simon [4 ]
O'Meara, Celia [5 ]
Wan, Simon [2 ]
Atkinson, David [1 ]
机构
[1] UCL, Ctr Med Imaging, Div Med, London, England
[2] UCL Hosp, Inst Nucl Med, London, England
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[4] Univ Coll London Hosp, Fac Engn, Ctr Med Imaging Comp, London NW1 2BU, England
[5] Sidra Med & Res Ctr, Doha, Qatar
基金
英国工程与自然科学研究理事会;
关键词
motion correction; PET/MR; lesion detection; lesion quantification; IMAGE-RECONSTRUCTION; MRI; LUNG;
D O I
10.2967/jnumed.114.151779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion during PET acquisition may lead to blurring in resulting images and underestimation of uptake parameters. The advent of integrated PET/MR scanners allows us to exploit the integration of modalities, using high spatial resolution and high-contrast MR images to monitor and correct PET images degraded by motion. We proposed a practical, anatomy-independent MR-based correction strategy for PET data affected by respiratory motion and showed that it can improve image quality both for PET acquired simultaneously to the motion-capturing MR and for PET acquired up to 1 h earlier during a clinical scan. Methods: To estimate the respiratory motion, our method needs only an extra 1-min dynamic MR scan, acquired at the end of the clinical PET/MR protocol. A respiratory signal was extracted directly from the PET list-mode data. This signal was used to gate the PET data and to construct a motion model built from the dynamic MR data. The estimated motion was then incorporated into the PET image reconstruction to obtain a single motion-corrected PET image. We evaluated our method in 2 steps. The PET-derived respiratory signal was compared with an MR measure of diaphragmatic displacement via a pencil-beam navigator. The motion-corrected images were compared with uncorrected images with visual inspection, line profiles, and standardized uptake value (SUV) in focally avid lesions. Results: We showed a strong correlation between the PET-derived and MR-derived respiratory signals for 9 patients, with a mean correlation of 0.89. We then showed 4 clinical case study examples (F-18-FDG and Ga-68-DOTATATE) using the motion-correction technique, demonstrating improvements in image sharpness and reduction of respiratory artifacts in scans containing pancreatic, liver, and lung lesions as well as cardiac scans. The mean increase in peak SUV (SUVpeak) and maximum SUV (SUVmax) in a patient with 4 pancreatic lesions was 23.1% and 34.5% in PET acquired simultaneously with motion-capturing MR, and 17.6% and 24.7% in PET acquired 50 min before as part of the clinical scan. Conclusion: We showed that a respiratory signal can be obtained from raw PET data and that the clinical PET image quality can be improved using only a short additional PET/MR acquisition. Our method does not need external respiratory hardware or modification of the normal clinical MR sequences.
引用
收藏
页码:890 / 896
页数:7
相关论文
共 50 条
  • [1] Joint PET-MR respiratory motion models for clinical PET motion correction
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    McClelland, Jamie
    Barnes, Anna
    Arridge, Simon
    Ourselin, Sebastien
    Atkinson, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17) : 6515 - 6530
  • [2] PRACTICAL PET RESPIRATORY MOTION CORRECTION IN CLINICAL SIMULTANEOUS PET/MR
    Manber, Richard
    Atkinson, David
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    O'Meara, Celia
    Wan, Simon
    Ourselin, Sebastien
    Arridge, Simon
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1580 - 1583
  • [3] Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    Fraioli, Francesco
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (09) : 1467 - 1473
  • [4] Clinical Evaluation of MR-Gated Respiratory Motion Correction in Simultaneous PET/MRI
    Li, Hui
    Meng, Xiangxi
    Guan, Xiangping
    Zhou, Nina
    Liu, Hui
    Zhang, Yan
    Yu, Boqi
    Zhu, Hua
    Li, Nan
    Yang, Zhi
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (04) : 297 - 302
  • [5] Respiratory motion correction of PET using MR-constrained PET-PET registration
    Balfour, Daniel R.
    Marsden, Paul K.
    Polycarpou, Irene
    Kolbitsch, Christoph
    King, Andrew P.
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [6] Motion Correction Strategies for Integrated PET/MR
    Fuerst, Sebastian
    Grimm, Robert
    Hong, Inki
    Souvatzoglou, Michael
    Casey, Michael E.
    Schwaiger, Markus
    Nekolla, Stephan G.
    Ziegler, Sibylle I.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (02) : 261 - 269
  • [7] Quantitative Evaluation of PET Respiratory Motion Correction Using MR Derived Simulated Data
    Polycarpou, Irene
    Tsoumpas, Charalampos
    King, Andrew P.
    Marsden, Paul K.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (06) : 3110 - 3116
  • [8] Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling
    Robson, Philip M.
    Trivieri, MariaGiovanna
    Karakatsanis, Nicolas A.
    Padilla, Maria
    Abgral, Ronan
    Dweck, Marc R.
    Kovacic, Jason C.
    Fayad, Zahi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (22)
  • [9] Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR
    Kolbitsch, Christoph
    Ahlman, Mark A.
    Davies-Venn, Cynthia
    Evers, Robert
    Hansen, Michael
    Peressutti, Devis
    Marsden, Paul
    Kellman, Peter
    Bluemke, David A.
    Schaeffter, Tobias
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (05) : 846 - 852
  • [10] PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections
    Gillman, Ashley
    Smith, Jye
    Thomas, Paul
    Rose, Stephen
    Dowson, Nicholas
    MEDICAL PHYSICS, 2017, 44 (12) : E430 - E445