Miniaturized Membrane Sensors for Potentiometric Determination of Metoprolol Tartrate and Hydrochlorothiazide

被引:0
|
作者
Ramadan, Nesrin K. [1 ]
Mohamed, Heba M. [1 ]
Mostafa, Azza A. [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, Cairo 11562, Egypt
关键词
Metoprolol tartrate; Hydrochlorothiazide; microsized electrodes; cyclodextrin; human plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; ION-SELECTIVE ELECTRODES; SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; HPLC METHOD; BENAZEPRIL HYDROCHLORIDE; BINARY-MIXTURE; BETA-BLOCKERS; DOSAGE FORMS; HUMAN PLASMA;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Four microsized graphite and platinum wire poly(vinyl chloride) matrix membrane electrodes responsive to some drugs affecting cardiovascular system, Metoprolol tartrate (MT) and Hydrochlorothiazide (HZ) were developed, described and characterized. These sensors were constructed by using (2-Hydroxypropyl)-beta-cyclodextrin (2HP beta-CD) as an ionophore which has a significant influence on increasing both membrane sensitivity and selectivity. The four sensors were fabricated in a polymeric matrix of carboxylated polyvinyl chloride (PVC-COOH) and dioctylphthalate (DOP) as a plasticizer, based on the interaction between the drugs and the dissociated COOH groups in the PVC-COOH. Fast and stable Nernstian responses of 1.0 x 10(-6)-1.0 x 10(-2) M for MT (sensors 1 and 2) and of 1.0 x 10(-7)-1.0 x 10(-3) M for HZ (sensors 3 and 4) over pH range 3.0-9.0 and 3.0-7.0 for the MT and HZ sensors respectively were obtained. Nernstian slopes of 56.2, 54.6, 19.0 and 20.8 mV/decade for electrodes 1-4 respectively were observed. The proposed method displayed useful analytical characteristics for the determination of MT and HZ in their pure powder forms with average recoveries of 99.11 +/- 0.357, 99.21 +/- 0.389, 100.08 +/- 0.459 and 100.28 +/- 0.438% for sensors 1-4 respectively. The lower limit of detection (LOD) were 5.5 x 10(-6), 4.5 x 10-6, 4.8 x 10(-8) and 5.0 x 10-8 M for sensors 1-4 respectively indicated high sensitivity. The four sensors displayed a good stability over a period of 6 weeks. The selectivity coefficients of the developed sensors indicated excellent selectivity. Results obtained by the four electrodes revealed the performance characteristics of these electrodes which evaluated according to IUPAC recommendations. The method was successively applied for the determination of MT and HZ in presence of each other, in presence of Salamide (SA), the main degradation product of HZ, in their pharmaceutical formulations and in human plasma samples. Statistical comparison between the results obtained by this method and those obtained by the official methods of the drugs was done and no significant difference was found.
引用
收藏
页码:344 / 352
页数:9
相关论文
共 50 条
  • [41] Potentiometric Sensors for Iron(III) Cations Determination
    Paut, Andrea
    Prkic, Ante
    Mitar, Ivana
    Guc, Lucija
    KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS, 2023, 72 (5-6): : 359 - 368
  • [42] Potentiometric Sensors and Multisensor Systems for the Determination of Lanthanides
    Yaroshenko, I. S.
    Alyapyshev, M. Yu.
    Babain, V. A.
    Legin, A. V.
    Kirsanov, D. O.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (10) : 1003 - 1018
  • [43] Novel potentiometric sensors for the selective determination of domperidone
    Kumar, K. Girish
    Augustine, Pearl
    John, Sareena
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (01) : 65 - 71
  • [44] Potentiometric Determination of Cholesterol-Reducing Drug, Ezetimibe Using Coated Wire Membrane Sensors
    Alarfaj, Nawal A.
    Aly, Fatma A.
    El-Tohamy, Maha F.
    SENSOR LETTERS, 2011, 9 (05) : 1830 - 1837
  • [45] Recent Advances on Potentiometric Membrane Sensors for Pharmaceutical Analysis
    Gupta, Vinod K.
    Nayak, Arunima
    Agarwal, Shilpi
    Singhal, Barkha
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2011, 14 (04) : 284 - 302
  • [46] RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS
    COSOFRET, VV
    BUCK, RP
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) : 1 - 58
  • [47] Spectrophotometric Determination of Metoprolol Tartrate in Pharmaceutical Dosage Forms on Complex Formation with Cu(II)
    Cesme, Mustafa
    Tarinc, Derya
    Golcu, Aysegul
    PHARMACEUTICALS, 2011, 4 (07): : 964 - 975
  • [48] Pramipexole Symmetric and Asymmetric Potentiometric PVC Membrane Sensors
    Faridbod, Farnoush
    Jamshidpour, Tahereh
    Ganjali, Mohammad Reza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (09): : 7990 - 8001
  • [49] A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine
    Hassan, Saad S. M.
    Fathy, Mahmoud Abdelwahab
    MICROCHIMICA ACTA, 2024, 191 (12)
  • [50] Polymeric membrane potentiometric sensors based on template-removal-free imprinted receptors for determination of antibiotics
    Wang, Xinyao
    Cui, Guohua
    Liang, Rongning
    Qin, Wei
    ANALYTICAL METHODS, 2024, 16 (20) : 3240 - 3248