Miniaturized Membrane Sensors for Potentiometric Determination of Metoprolol Tartrate and Hydrochlorothiazide

被引:0
|
作者
Ramadan, Nesrin K. [1 ]
Mohamed, Heba M. [1 ]
Mostafa, Azza A. [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, Cairo 11562, Egypt
关键词
Metoprolol tartrate; Hydrochlorothiazide; microsized electrodes; cyclodextrin; human plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; ION-SELECTIVE ELECTRODES; SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; HPLC METHOD; BENAZEPRIL HYDROCHLORIDE; BINARY-MIXTURE; BETA-BLOCKERS; DOSAGE FORMS; HUMAN PLASMA;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Four microsized graphite and platinum wire poly(vinyl chloride) matrix membrane electrodes responsive to some drugs affecting cardiovascular system, Metoprolol tartrate (MT) and Hydrochlorothiazide (HZ) were developed, described and characterized. These sensors were constructed by using (2-Hydroxypropyl)-beta-cyclodextrin (2HP beta-CD) as an ionophore which has a significant influence on increasing both membrane sensitivity and selectivity. The four sensors were fabricated in a polymeric matrix of carboxylated polyvinyl chloride (PVC-COOH) and dioctylphthalate (DOP) as a plasticizer, based on the interaction between the drugs and the dissociated COOH groups in the PVC-COOH. Fast and stable Nernstian responses of 1.0 x 10(-6)-1.0 x 10(-2) M for MT (sensors 1 and 2) and of 1.0 x 10(-7)-1.0 x 10(-3) M for HZ (sensors 3 and 4) over pH range 3.0-9.0 and 3.0-7.0 for the MT and HZ sensors respectively were obtained. Nernstian slopes of 56.2, 54.6, 19.0 and 20.8 mV/decade for electrodes 1-4 respectively were observed. The proposed method displayed useful analytical characteristics for the determination of MT and HZ in their pure powder forms with average recoveries of 99.11 +/- 0.357, 99.21 +/- 0.389, 100.08 +/- 0.459 and 100.28 +/- 0.438% for sensors 1-4 respectively. The lower limit of detection (LOD) were 5.5 x 10(-6), 4.5 x 10-6, 4.8 x 10(-8) and 5.0 x 10-8 M for sensors 1-4 respectively indicated high sensitivity. The four sensors displayed a good stability over a period of 6 weeks. The selectivity coefficients of the developed sensors indicated excellent selectivity. Results obtained by the four electrodes revealed the performance characteristics of these electrodes which evaluated according to IUPAC recommendations. The method was successively applied for the determination of MT and HZ in presence of each other, in presence of Salamide (SA), the main degradation product of HZ, in their pharmaceutical formulations and in human plasma samples. Statistical comparison between the results obtained by this method and those obtained by the official methods of the drugs was done and no significant difference was found.
引用
收藏
页码:344 / 352
页数:9
相关论文
共 50 条
  • [31] Differential pulse voltammetric method for the individual and simultaneous determination of antihypertensive drug metoprolol and its association with hydrochlorothiazide in pharmaceutical dosage forms
    Rossi Salamanca-Neto, Carlos Alberto
    Pires Eisele, Ana Paula
    Resta, Vitoria Gouveia
    Scremin, Jessica
    Sartori, Elen Romao
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 630 - 638
  • [32] Development and validation of a RP-HPLC method for simultaneous determination of cimetidine, metoprolol tartrate and phenol red for intestinal perfusion studies
    Ermis, Meryem
    Kir, Fatma
    Sahin, Selma
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2025, 1252
  • [33] Stability indicating potentiometric method for the determination of palonosetron HCl using two different sensors
    Tantawy, Mahmoud A.
    Elshabasy, Dalia A.
    Youssef, Nadia F.
    Amer, Sawsan M.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [34] Selective Membrane Sensors for the Determination of Sildenafil, Tadalafil and Vardanafil
    Alharthi, Salman S.
    Khalil, Sabry
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 8336 - 8347
  • [35] Ionophore-based potentiometric PVC membrane sensors for determination of phenobarbitone in pharmaceutical formulations
    Alrabiah, Haitham
    Al-Majed, Abdulrahman
    Abounassif, Mohammed
    Mostafa, Gamal A. E.
    ACTA PHARMACEUTICA, 2016, 66 (04) : 503 - 514
  • [36] Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
    Ahmadi, Farhad
    Asaadi, Nasim
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2013, 12 (04): : 645 - 657
  • [37] Development and validation of kinetic spectrophotometric method for the determination of metoprolol tartrate in pharmaceutical preparations
    Rahman, N
    Ahmad, Y
    Azmi, SNH
    CHEMIA ANALITYCZNA, 2005, 50 (04): : 769 - 783
  • [38] Miniaturized ionophore-based potentiometric sensors for the flow-injection determination of metformin in pharmaceutical formulations and biological fluids
    Khaled, Elmorsy
    Kamel, Manal S.
    Hassan, Hassan N.
    Abd El-Alim, Sameh H.
    Aboul-Enein, Hassan Y.
    ANALYST, 2012, 137 (23) : 5680 - 5687
  • [39] Potentiometric Sensors for the Determination of Anionic Surfactants - A Review
    Jozanovic, Marija
    Sakac, Nikola
    Karnas, Maja
    Medvidovic-Kosanovic, Martina
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 51 (02) : 115 - 137
  • [40] Potentiometric Sensors and Multisensor Systems for the Determination of Lanthanides
    I. S. Yaroshenko
    M. Yu. Alyapyshev
    V. A. Babain
    A. V. Legin
    D. O. Kirsanov
    Journal of Analytical Chemistry, 2019, 74 : 1003 - 1018