Characterization of a urea optical sensor based on polypyrrole

被引:25
|
作者
de Marcos, S [1 ]
Hortigüela, R
Galbán, J
Castillo, JR
Wolfbeis, OS
机构
[1] Univ Zaragoza, Fac Sci, Dept Analyt Chem, GEAS,Analyt Spectrometry & Sensors Grp, E-50009 Zaragoza, Spain
[2] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
optical sensor; urea; urease; polypyrrole;
D O I
10.1007/BF01242915
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical sensor for urea determination is presented. It is based on the enzymatic reaction with urease, which is first photoimmobilized with polyacrylamide onto a chemically polymerized polypyrrole (PPy) film. The main advantage of this sensor is that no indicator dye or pH indicator is needed, because PPy itself acts as the support and the indicator. These PPy films show an absorbance spectrum in the near IR range which is pH dependent. The variation of absorbance is thus directly related to the change of pH caused during the enzymatic reaction, which is also dependent on the urea concentration. The linear range of the sensor is from 0.06 to 1 M of urea, which is the common level of urea concentration found in blood and urine samples.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [21] Characterization of polypyrrole films for use in optical sensing
    deMarcos, S
    Wolfbeis, OS
    SENSORS AND MATERIALS, 1997, 9 (04) : 253 - 265
  • [23] ELECTROCHEMICAL SYNTHEZIS AND CHARACTERIZATION OF POLYPYRROLE FOR DODECYLSULFATE SENSOR MEMBRANE
    Watoni, Abdul Haris
    Gandasasmita, Suryo
    Noviandri, Indra
    Buchari
    INDONESIAN JOURNAL OF CHEMISTRY, 2007, 7 (03) : 249 - 253
  • [24] Amperometric urea biosensors based on the entrapment of urease in polypyrrole films
    Soares, Juliana Coatrini
    Brisolari, Andre
    Rodrigues, Valquiria da Cruz
    Sanches, Edgar Aparecido
    Goncalves, Debora
    REACTIVE & FUNCTIONAL POLYMERS, 2012, 72 (02): : 148 - 152
  • [25] Polypyrrole-based amperometric flow injection biosensor for urea
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) : 107 - 113
  • [26] Amperometric urea biosensor based on immobilized urease on polypyrrole and macroporous polypyrrole modified Pt electrode
    Hosseinian, Maliheh
    Najafpour, Ghasem
    Rahimpour, Ahmad
    TURKISH JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1063 - 1074
  • [27] Potentiometric Urea Biosensor Based on a Urease-Immobilized Polypyrrole
    Prissanaroon-Ouajai, Walaiporn
    Sirivat, Anuvat
    Pigram, Paul J.
    Brack, Narelle
    MACROMOLECULAR SYMPOSIA, 2015, 354 (01) : 334 - 339
  • [28] POLYPYRROLE-BASED SENSOR FOR HYDRAZINE AND AMMONIA
    RATCLIFFE, NM
    ANALYTICA CHIMICA ACTA, 1990, 239 (02) : 257 - 262
  • [29] Polypyrrole based gas sensor for ammonia detection
    Dunst, K. J.
    Cysewska, K.
    Kalinowski, P.
    Jasinski, P.
    39TH INTERNATIONAL MICROELECTRONICS AND PACKAGING IMAPS POLAND 2015 CONFERENCE, 2016, 104
  • [30] A novel paper pH sensor based on polypyrrole
    Yue, F
    Ngin, TS
    Hailin, G
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (01) : 33 - 39