Efficient Similarity Measurement between Digitally Reconstructed Radiograph and Fluoroscopy for 3D-2D Registration

被引:0
|
作者
Rao, Chaitanya R. H. [1 ]
Anitha, H. [1 ]
Bhat, Shyamasunder N. [2 ]
Bhat, Vidya [1 ]
机构
[1] Manipal Inst Technol, Dept Elect & Commun, Manipal, Karnataka, India
[2] Kasturba Med Coll & Hosp, Dept Orthopaed, Manipal, Karnataka, India
来源
2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI) | 2018年
关键词
3D-2D registration; Digitally Reconstructed Radiographs; Compressed Sensing; Sparsity; Similarity measures; IMAGE REGISTRATION; LOCALIZATION;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This work aims to make use of compressed sensing to exploit the redundant nature hidden in the image and reduce the computational complexity involved in DRR generation. As a result, radiation risk to the patient can be reduced whilst maintaining an acceptable level of accuracy thus resulting in speed-up in DRR generation using the multi-resolution approach compared to the conventional ray casting approach. Also in this research, different gradient based similarity metrics were compared on the basis of accuracy to achieve robustness against image content mismatch.
引用
收藏
页码:611 / 616
页数:6
相关论文
共 50 条
  • [21] Similarity metrics based on nonadditive entropies for 2D-3D multimodal biomedical image registration
    Wachowiak, MP
    Smolilcova, R
    Tourassi, GD
    Elmaghraby, AS
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1090 - 1100
  • [22] Known-component 3D-2D registration for quality assurance of spine surgery pedicle screw placement
    Uneri, A.
    De Silva, T.
    Stayman, J. W.
    Kleinszig, G.
    Vogt, S.
    Khanna, A. J.
    Gokaslan, Z. L.
    Wolinsky, J-P
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 8007 - 8024
  • [23] Self-calibration of cone-beam CT geometry using 3D-2D image registration
    Ouadah, S.
    Stayman, J. W.
    Gang, G. J.
    Ehtiati, T.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2613 - 2632
  • [24] Determination of Error in 3D CT to 2D Fluoroscopy Image Registration for Endobronchial Guidance
    Varble, Nicole
    Chen, Alvin
    Sinha, Ayushi
    Lee, Brian
    de Ruiter, Quirina
    Wood, Bradford
    Bydlon, Torre
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VII, 2021, 12907 : 335 - 344
  • [25] 2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment
    Bifulco, P.
    Cesarelli, M.
    Allen, R.
    Romano, M.
    Fratini, A.
    Pasquariello, G.
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2010,
  • [26] Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration
    Uneri, A.
    De Silva, T.
    Goerres, J.
    Jacobson, M. W.
    Ketcha, M. D.
    Reaungamornrat, S.
    Kleinszig, G.
    Vogt, S.
    Khanna, A. J.
    Osgood, G. M.
    Wolinsky, J-P
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08) : 3330 - 3351
  • [27] 3D-2D Image Registration for Craniofacial Superimposition in Forensic Medicine using Covariance Matrix Adaptation Evolution Strategy
    Santamaria, Jose
    Cordon, Oscar
    Damas, Sergio
    Ibanez, Oscar
    2009 9TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, 2009, : 622 - +
  • [28] Dual-Projection 3D-2D Registration for Surgical Guidance: Preclinical Evaluation of Performance and Minimum Angular Separation
    Uneri, A.
    Otake, Y.
    Wang, A. S.
    Kleinszig, G.
    Vogt, S.
    Gallia, G. L.
    Rigamonti, D.
    Wolinsky, J. -P.
    Gokaslan, Z. L.
    Khanna, A. J.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [29] A Fast and Robust Framework for 3D/2D Model to Multi-Frame Fluoroscopy Registration
    Saadat, Shabnam
    Asikuzzaman, Md.
    Pickering, Mark R.
    Perriman, Diana M.
    Scarvell, Jennie M.
    Smith, Paul N.
    IEEE ACCESS, 2021, 9 : 134223 - 134239
  • [30] Toward Semantically-Consistent Deformable 2D-3D Registration for 3D Craniofacial Structure Estimation From a Single-View Lateral Cephalometric Radiograph
    Jiang, Yikun
    Pei, Yuru
    Xu, Tianmin
    Yuan, Xiaoru
    Zha, Hongbin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2025, 44 (02) : 685 - 697