Determination of Ni(II) with picolinaldehyde-4-phenyl-3-thiosemicarbazone used as a chromogenic reagent in a nonionic micellar system

被引:3
作者
Balouch, Aamna [1 ]
Bhanger, Muhammad Iqbal [1 ]
Talpur, Farah Naz [1 ]
Hinze, Willie L. [2 ]
机构
[1] Univ Sindh, Natl Ctr Excellence Analyt Chem, Jamshoro, Pakistan
[2] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
关键词
Spectrophotometry; surfactant; Ni(II); PAPT; ATOMIC-ABSORPTION-SPECTROMETRY; SODIUM DODECYL-SULFATE; SPECTROPHOTOMETRIC DETERMINATION; NICKEL; COBALT; COMPLEX; ACID; SEPARATION; EXTRACTION; COPPER;
D O I
10.3906/kim-1005-643
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Spectrophotometric determination of Ni(II) was carried out using picolinaldehyde-4-phenyl-3-thiosemicarbazone (PAPT) as a complexing/chromogenic reagent. The possibility of using a micellar system was explored to enhance the degree of detection and allow a more sensitive spectrophotometric method for the determination of nickel ions. The anionic surfactant Triton X-100 greatly enhanced the molar absorptivity and limit of detection relative to that observed with bulk water or an organic solvent. The linear calibration graphs were obtained for 0.5-2.0 mg L-1 and 0.001-1.0 mg L-1 of Ni(II) in aqueous and surfactant media, respectively. Using this approach, the limit of detection for the PAPT-Ni(II) complex (based on 3 sigma of blank absorbance/slope) was found to be 0.0008 mg L-1 with a micellar enhancement reagent. The interference from over 50 cations, anions, and complexing agents was studied at 0.50 mg L-1 of Ni(II); most metal ions can be tolerated in considerable amounts in aqueous micellar solutions.
引用
收藏
页码:925 / 937
页数:13
相关论文
共 32 条