Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy

被引:23
作者
Diot, Quentin [1 ]
Kavanagh, Brian [1 ]
Timmerman, Robert [2 ]
Miften, Moyed [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
[2] Univ Texas SW Med Sch, Dept Radiat Oncol, Dallas, TX 75390 USA
关键词
VMAT; SBRT; lung; liver; prostate; biological-based optimization; RADIOTHERAPY; PROSTATE; IMRT; INDEX;
D O I
10.1118/1.3668059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To describe biological-based optimization and Monte Carlo (MC) dose calculation-based treatment planning for volumetric modulated arc therapy (VMAT) delivery of stereotactic body radiation therapy (SBRT) in lung, liver, and prostate patients. Methods: Optimization strategies and VMAT planning parameters using a biological-based optimization MC planning system were analyzed for 24 SBRT patients. Patients received a median dose of 45 Gy [range, 34-54 Gy] for lung tumors in 1-5 fxs and a median dose of 52 Gy [range, 48-60 Gy] for liver tumors in 3-6 fxs. Prostate patients received a fractional dose of 10 Gy in 5 fxs. Biological-cost functions were used for plan optimization, and its dosimetric quality was evaluated using the conformity index (CI), the conformation number (CN), the ratio of the volume receiving 50% of the prescription dose over the planning target volume (Rx/PTV50). The quality and efficiency of the delivery were assessed according to measured quality assurance (QA) passing rates and delivery times. For each disease site, one patient was replanned using physical cost function and compared to the corresponding biological plan. Results: Median CI, CN, and Rx/PTV50 for all 24 patients were 1.13 (1.02-1.28), 0.79 (0.70-0.88), and 5.3 (3.1-10.8), respectively. The median delivery rate for all patients was 410 MU/min with a maximum possible rate of 480 MU/min (85%). Median QA passing rate was 96.7%, and it did not significantly vary with the tumor site. Conclusions: VMAT delivery of SBRT plans optimized using biological-motivated cost-functions result in highly conformal dose distributions. Plans offer shorter treatment-time benefits and provide efficient dose delivery without compromising the plan conformity for tumors in the prostate, lung, and liver, thereby improving patient comfort and clinical throughput. The short delivery times minimize the risk of patient setup and intrafraction motion errors often associated with long SBRT treatment delivery times. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3668059]
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
[31]   Dual-gated volumetric modulated arc therapy [J].
Fahimian, Benjamin ;
Wu, Junqing ;
Wu, Huanmei ;
Geneser, Sarah ;
Xing, Lei .
RADIATION ONCOLOGY, 2014, 9
[32]   Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT) [J].
Men, Chunhua ;
Romeijn, H. Edwin ;
Jia, Xun ;
Jiang, Steve B. .
MEDICAL PHYSICS, 2010, 37 (11) :5787-5791
[33]   A fast optimization approach for treatment planning of volumetric modulated arc therapy [J].
Yan, Hui ;
Dai, Jian-Rong ;
Li, Ye-Xiong .
RADIATION ONCOLOGY, 2018, 13
[34]   Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis [J].
McGrath, Samuel D. ;
Matuszak, Martha M. ;
Yan, Di ;
Kestin, Larry L. ;
Martinez, Alvaro A. ;
Grills, Inga S. .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) :153-157
[35]   The Feasibility and Efficiency of Volumetric Modulated Arc Therapy-Based Breath Control Stereotactic Body Radiotherapy for Liver Tumors [J].
Qiu, Jian-Jian ;
Ge, Weiqiang ;
Zhang, Libo ;
Yao, Ye ;
Zheng, Xiangpeng .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (05) :674-682
[36]   Stereotactic body radiation therapy using a respiratory-gated volumetric-modulated arc therapy technique for small hepatocellular carcinoma [J].
Jeong, Yuri ;
Jung, Jinhong ;
Cho, Byungchul ;
Kwak, Jungwon ;
Jeong, Chiyoung ;
Kim, Jong Hoon ;
Park, Jin-hong ;
Kim, So Yeon ;
Shim, Ju Hyun ;
Kim, Kang Mo ;
Lim, Young-Suk ;
Lee, Han Chu ;
Yoon, Sang Min .
BMC CANCER, 2018, 18
[37]   Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy [J].
S. Clemente ;
M. Cozzolino ;
C. Oliviero ;
A. Fiorentino ;
C. Chiumento ;
V. Fusco .
Clinical and Translational Oncology, 2014, 16 :141-146
[38]   Analysis of Dose Distribution and Risk of Pneumonitis in Stereotactic Body Radiation Therapy for Centrally Located Lung Tumors: A Comparison of Robotic Radiosurgery, Helical Tomotherapy and Volumetric Modulated Arc Therapy [J].
Kannarunimit, Danita ;
Descovich, Martina ;
Garcia, Aaron ;
Chen, Josephine ;
Weinberg, Vivian ;
Mcguinness, Christopher ;
Pinnaduwage, Dilini ;
Murnane, John ;
Gottschalk, Alexander R. ;
Yom, Sue S. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (01) :49-60
[39]   Breathing-motion induced interplay effects for stereotactic body radiotherapy of liver tumours using flattening-filter free volumetric modulated arc therapy [J].
Edvardsson, A. ;
Scherman, J. ;
Nilsson, M. P. ;
Wennberg, B. ;
Nordstrom, F. ;
Ceberg, C. ;
Ceberg, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (02)
[40]   Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy [J].
Mallory, Matthew ;
Pokhrel, Damodar ;
Badkul, Rajeev ;
Jiang, Hongyu ;
Lominska, Christopher ;
Wang, Fen .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02) :54-61