Characterization of some physical and chromatographic properties of monolithic poly(styrene-co-divinylbenzene) columns

被引:0
作者
Oberacher, H
Premstaller, A
Huber, CG
机构
[1] Univ Saarland, D-66123 Saarbrucken, Germany
[2] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
monolithic columns; capillary columns; stationary phases; LC; poly(styrene-divinylbenzene); peptides; nucleic acids;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 mum i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C-18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C-18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [31] Silica particles encapsulated poly(styrene-divinylbenzene) monolithic stationary phases for μ-high performance liquid chromatography
    Bakry, R.
    Stoeggl, W. M.
    Hochleitner, E. O.
    Stecher, G.
    Huck, C. W.
    Bonn, G. K.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1132 (1-2) : 183 - 189
  • [32] Comments on the Implementation of a Simple Peak Capacity Optimization Procedure and Comparison of Poly(styrene-divinylbenzene) and RP-18 Silica Monolithic Capillary Columns of 5-cm for the Analysis of Protein Digests
    Rozenbrand, Johan
    van Bennekom, Wouter P.
    CHROMATOGRAPHIA, 2013, 76 (23-24) : 1595 - 1602
  • [33] Monolithic poly(p-methylstyrene-co-1,2-bis(p-vinylphenyl)ethane) capillary columns as novel styrene stationary phases for biopolymer separation
    Trojer, Lukas
    Lubbad, Said H.
    Bisjak, Clemens P.
    Bonn, Guenther K.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (01) : 56 - 66
  • [34] Poly(HEMA-co-NBMI) Monolithic Cryogel Columns for IgG Adsorption
    Murat Uygun
    R. Hilal Şenay
    Nesibe Avcıbaşı
    Sinan Akgöl
    Applied Biochemistry and Biotechnology, 2014, 172 : 1574 - 1584
  • [35] Poly(HEMA-co-NBMI) Monolithic Cryogel Columns for IgG Adsorption
    Uygun, Murat
    Senay, R. Hilal
    Avcibasi, Nesibe
    Akgol, Sinan
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 172 (03) : 1574 - 1584
  • [36] Solid-phase extraction method for the isolation of plant thionins from European mistletoe, wheat and barley using zirconium silicate embedded in poly(styrene-co-divinylbenzene) hollow-monoliths
    Hussain, Shah
    Guezel, Yueksel
    Schoenbichler, Stefan A.
    Rainer, Matthias
    Huck, Christian W.
    Bonn, Guenther K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (23) : 7509 - 7521
  • [37] Comments on the Implementation of a Simple Peak Capacity Optimization Procedure and Comparison of Poly(styrene–divinylbenzene) and RP-18 Silica Monolithic Capillary Columns of 5-cm for the Analysis of Protein Digests
    Johan Rozenbrand
    Wouter P. van Bennekom
    Chromatographia, 2013, 76 : 1595 - 1602
  • [38] Basic Chromatographic Properties of Polyethylene Glycol-type, Polymer-based Monolithic Columns
    Mori, Tomoko
    Kubo, Takuya
    Hosoya, Ken
    ANALYTICAL SCIENCES, 2010, 26 (03) : 311 - 316
  • [39] Influence of the polymerisation time on the porous and chromatographic properties of monolithic poly(1,2-bis(p-vinylphenyl))ethane capillary columns
    Greiderer, Andreas
    Trojer, Lukas
    Huck, Christian W.
    Bonn, Guenther K.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (45) : 7747 - 7754
  • [40] Influence of polyvinylpyrrolidone on the hydrophobic properties of partially porous poly(styrene-divinylbenzene) particles for biological applications
    Kao, CY
    Lo, TC
    Lee, WC
    JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 87 (11) : 1818 - 1824