Validity, reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-BESTest and brief-BESTest in patients with end-stage renal disease

被引:10
|
作者
Jacome, Cristina [1 ,2 ]
Flores, Ines [2 ]
Martins, Filipa [2 ]
Castro, Conceicao [3 ]
McPhee, Charlotte C. [4 ]
Shepherd, Ellen [4 ]
Demain, Sara [4 ]
Figueiredo, Daniela [2 ,5 ]
Marques, Alda [1 ,2 ,6 ]
机构
[1] Univ Aveiro ESSUA, Resp Res & Rehabil Lab Lab 3R, Sch Hlth Sci, Agras Crasto Campus Univ Santiago,Edificio 30, P-3810193 Aveiro, Portugal
[2] Univ Aveiro ESSUA, Sch Hlth Sci, Aveiro, Portugal
[3] Ctr Hemodialise SA, Ctr Dial, Sao Joao Da Madeira, Portugal
[4] Univ Southampton, Fac Hlth Sci, Southampton, Hants, England
[5] Univ Aveiro, Ctr Hlth Technol & Serv Res Cintesis UA, Aveiro, Portugal
[6] Univ Aveiro, Inst Res Biomed iBiMED, Aveiro, Portugal
关键词
Chronic kidney failure; dialysis; postural balance; risk assessment; reproducibility of results; POSTURAL CONTROL; FALLS; INDIVIDUALS; OLDER; REHABILITATION; PEOPLE; CLASSIFICATION; PREVALENCE; DISABILITY; GUIDELINES;
D O I
10.1080/09638288.2017.1375034
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: This study determined the validity, test-retest reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-balance evaluation systems test (Mini-BESTest) and brief-balance evaluation systems test (Brief-BESTest) in patients with end-stage renal disease. Methods: A cross-sectional study with 74 patients with end-stage renal disease (male 66.2%; 63.9 +/- 15.1 years old) was conducted. Participants were asked to report the number of falls during the previous 12 months and to complete the activity-specific balance confidence (ABC) scale. The BESTest was administered, and the Mini-BESTest and Brief-BESTest scores were computed based on the BESTest performance. Validity was assessed by correlating balance tests with each other and with the ABC scale. Test-retest relative reliability and agreement were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level were established. Results: Balance test scores were significantly correlated with each other (spearman's correlation = 0.89-0.92) and with the ABC scale (spearman's correlation = 0.49-0.59). Balance tests presented high test-retest reliability (ICC = 0.84-0.94), with no evidence of bias. Minimal detectable change values were 10.8 (expressed as a percentage 13.5%), 5.3 (23.7%) and 5.6 (34%) points for the BESTest, Mini-BESTest and Brief-BESTest, respectively. Conclusions: All tests are valid and reliable to assess balance in patients with end-stage renal disease. Nevertheless, based on the minimal detectable changes found, BESTest and Mini-BESTest may be the most recommended tests for this specific population. .
引用
收藏
页码:3171 / 3176
页数:6
相关论文
共 39 条
  • [1] Reliability and validity of Persian versions of Mini-BESTest and Brief-BESTest in persons with Parkinson's disease
    Nakhostin-Ansari, Amin
    Ansari, Noureddin Nakhostin
    Mellat-Ardakani, Milad
    Nematizad, Mostafa
    Naghdi, Soofia
    Babaki, MohammadJavad
    Farhangian, Mehdi
    Habibi, Amir Hassan
    Tafakhori, Abbas
    Hasson, Scott
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (09) : 1264 - 1272
  • [2] ON THE STRUCTURAL VALIDITY OF BESTEST, MINI-BESTEST AND BRIEF-BESTEST: EXPLORE FIRST AND ONLY THEN CONFIRM
    Franchignoni, Franco
    Giordano, Andrea
    JOURNAL OF REHABILITATION MEDICINE, 2020, 52 (09)
  • [3] Validity, Reliability, and Ability to Identify Fall Status of the Berg Balance Scale, BESTest, Mini-BESTest, and Brief-BESTest in Patients With COPD
    Jacome, Cristina
    Cruz, Joana
    Oliveira, Ana
    Marques, Alda
    PHYSICAL THERAPY, 2016, 96 (11): : 1807 - 1815
  • [4] Reliability of the Mini-BESTest and Brief-BESTest for assessing patients with incomplete spinal cord injury
    Morooka, Yusuke
    Takakura, Yasuyuki
    Kunisawa, Yosuke
    Okubo, Yuya
    Araki, Shinta
    Obayashi, Shigeru
    SPINAL CORD, 2024, 62 (12) : 676 - 682
  • [5] Reliability, Validity, and Ability to Identity Fall Status of the Berg Balance Scale, Balance Evaluation Systems Test (BESTest), Mini-BESTest, and Brief-BESTest in Older Adults Who Live in Nursing Homes
    Pereira Viveiro, Larissa Alamino
    Vieira Gomes, Gisele Cristine
    Ribeiro Bacha, Jessica Maria
    Carvas Junior, Nelson
    Kallas, Marina Esteves
    Reis, Muriel
    Jacob Filho, Wilson
    Pompeu, Jose Eduardo
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2019, 42 (04) : E45 - E54
  • [6] Comparative Utility of the BESTest, Mini-BESTest, and Brief-BESTest for Predicting Falls in Individuals With Parkinson Disease: A Cohort Study
    Duncan, Ryan P.
    Leddy, Abigail L.
    Cavanaugh, James T.
    Dibble, Leland E.
    Ellis, Terry D.
    Ford, Matthew P.
    Foreman, K. Bo
    Earhart, Gammon M.
    PHYSICAL THERAPY, 2013, 93 (04): : 542 - 550
  • [7] Reproducibility of the Balance Evaluation Systems Test (BESTest) and the Mini-BESTest in school-aged children
    Dewar, R.
    Claus, A. P.
    Tucker, K.
    Ware, R.
    Johnston, L. M.
    GAIT & POSTURE, 2017, 55 : 68 - 74
  • [8] Reliability, validity and minimal detectable change of the Mini-BESTest in Greek participants with chronic stroke
    Lampropoulou, Sofia I.
    Billis, Evdokia
    Gedikoglou, Ingrid A.
    Michailidou, Christina
    Nowicky, Alexander V.
    Skrinou, Dimitra
    Michailidi, Fotini
    Chandrinou, Danae
    Meligkoni, Margarita
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (02) : 171 - 182
  • [9] Validity, reliability and minimal detectable change of Mini-BESTest Turkish version in neurological disorders
    Karatekin, Bilinc Dogruoz
    Icagasioglu, Afitap
    Pasin, Ozge
    ACTA NEUROLOGICA BELGICA, 2023, 123 (04) : 1519 - 1525
  • [10] Reliability and minimal detectable change of the mini-BESTest in adults with spinal cord injury in a rehabilitation setting
    Roy, Audrey
    Higgins, Johanne
    Nadeau, Sylvie
    PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (01) : 126 - 134