Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination

被引:258
作者
Kobal, SL
Trento, L
Baharami, S
Tolstrup, K
Naqvi, TZ
Cercek, B
Neuman, Y
Mirocha, J
Kar, S
Forrester, JS
Siegel, RJ
机构
[1] Cedars Sinai Med Ctr, Div Cardiol, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
关键词
D O I
10.1016/j.amjcard.2005.05.060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared the accuracy of cardiovascular diagnoses by medical students operating a small hand-carried ultrasound (HCU) device with that of board-certified cardiologists using standard physical examinations. Sixty-one patients (38% women; mean age 70 19 years) with clinically significant cardiac disease had HCU studies performed by I of 2 medical students with 18 hours of training in cardiac ultrasound and physical examinations by 1 of 5 cardiologists. Diagnostic accuracy was determined by standard echocardiography. Two-hundred thirty-nine abnormal findings were detected by standard echocardiography. The students correctly identified 75% (180 of 239) of the pathologies, whereas cardiologists found 49% (116 of 239) (p <0.001). The students' diagnostic specificity of 87% was also greater than cardiologists' specificity of 76% (p <0.001). For nonvalvular pathologies (115 findings), students' sensitivity was 61 %, compared with 47% for cardiologists (p = 0.040). There were 124 clinically significant valvular lesions (111 regurgitations, 13 stenoses). Students' and cardiologists' sensitivities for recognizing lesions that cause a systolic murmur were 93% and 62% (p <0.001), respectively. Students' sensitivity for diagnosing lesions that produce a diastolic murmur was 75%; cardiologists recognized 16% of these lesions (p <0.001). The diagnostic accuracy of medical students using an HCU device after brief echocardiographic training to detect valvular disease, left ventricular dysfunction, enlargement, and hypertrophy was superior to that of experienced cardiologists performing cardiac physical examinations. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1002 / 1006
页数:5
相关论文
共 23 条
[1]   HEART SOUNDS IN AGED [J].
BETHEL, CS ;
CROW, EW .
AMERICAN JOURNAL OF CARDIOLOGY, 1963, 11 (06) :763-&
[2]   Utility of hand-carried ultrasound devices used by cardiologists with and without significant echocardiographic experience in the cardiology inpatient and outpatient settings [J].
Bruce, CJ ;
Montgomery, SC ;
Bailey, KR ;
Tajik, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (11) :1273-+
[3]  
DeCara J M, 2003, Eur J Echocardiogr, V4, P141, DOI 10.1053/euje.2002.0617
[4]   INTEROBSERVER AGREEMENT AND ACCURACY OF BEDSIDE ESTIMATION OF RIGHT AND LEFT-VENTRICULAR EJECTION FRACTION IN ACUTE MYOCARDIAL-INFARCTION [J].
GADSBOLL, N ;
HOILUNDCARLSEN, PF ;
NIELSEN, GG ;
BERNING, J ;
BRUUN, NE ;
STAGE, P ;
HEIN, E .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (18) :1301-1307
[5]   Clinical auscultation skills in pediatric residents [J].
Gaskin, PRA ;
Owens, SE ;
Talner, NS ;
Sanders, SP ;
Li, JS .
PEDIATRICS, 2000, 105 (06) :1184-1187
[6]   How useful is hand-carried bedside echocardiography in critically ill patients? [J].
Goodkin, GM ;
Spevack, DM ;
Tunick, PA ;
Kronzon, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) :2019-2022
[7]   DETECTION OF AORTIC-INSUFFICIENCY BY STANDARD ECHOCARDIOGRAPHY, PULSED DOPPLER ECHOCARDIOGRAPHY, AND ASCULTATION - A COMPARISON OF ACCURACIES [J].
GRAYBURN, PA ;
SMITH, MD ;
HANDSHOE, R ;
FRIEDMAN, BJ ;
DEMARIA, AN .
ANNALS OF INTERNAL MEDICINE, 1986, 104 (05) :599-605
[8]   ACCURACY AND REPRODUCIBILITY OF PRECORDIAL PERCUSSION AND PALPATION FOR DETECTING INCREASED LEFT-VENTRICULAR END-DIASTOLIC VOLUME AND MASS - A COMPARISON OF PHYSICAL FINDINGS AND ULTRAFAST COMPUTED-TOMOGRAPHY OF THE HEART [J].
HECKERLING, PS ;
WIENER, SL ;
WOLFKIEL, CJ ;
KUSHNER, MS ;
DODIN, EM ;
JELNIN, V ;
FUSMAN, B ;
CHOMKA, EV .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (16) :1943-1948
[9]   Echocardiography in the evaluation of systolic murmurs of unknown cause [J].
Jost, CHA ;
Turina, J ;
Mayer, K ;
Seifert, B ;
Amann, FW ;
Buechi, M ;
Facchini, M ;
Brunner-La Rocca, HP ;
Jenni, R .
AMERICAN JOURNAL OF MEDICINE, 2000, 108 (08) :614-620
[10]   CAUSES OF FALSE-NEGATIVE AUSCULTATION OF REGURGITANT LESIONS - A DOPPLER ECHOCARDIOGRAPHIC STUDY OF 294 PATIENTS [J].
KINNEY, EL .
JOURNAL OF GENERAL INTERNAL MEDICINE, 1988, 3 (05) :429-434