LONG LOST MICRA LEADLESS PACEMAKER FOUND IN THE RIGHT PULMONARY ARTERY

被引:0
|
作者
Badejoko, Solomon O.
Singh, Parampreet K.
Williams, Jennifer J.
Chothia, Rashaad
机构
[1] St Josephs Med Ctr, Stockton, CA USA
[2] Stanford Univ, Stanford, CA 94305 USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:2499 / 2499
页数:1
相关论文
共 50 条
  • [1] Lost but Not Lost-Embolization of a Leadless Pacemaker to the Pulmonary Artery with Consecutive Endovascular Recovery
    Barbieri, Fabian
    Kranewitter, Christof
    Frech, Andreas
    Hintringer, Florian
    Stuehlinger, Markus
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (04)
  • [2] EVALUATING LONG TERM PERFORMANCE OF MICRA VA LEADLESS PACEMAKER
    Shaikh, Omar
    Silva, Sandra
    Karahacioglu, Berkay
    Patrick, Heck
    Begley, David
    Martin, Claire
    HEART, 2021, 107 : A81 - A82
  • [3] First in man right atrial appendage implantation of a Micra leadless pacemaker
    Pinon, Pauline
    Iserin, Laurence
    Hachem, Fatma
    Waldmann, Victor
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1232 - 1234
  • [4] Implantation of a MICRA Leadless Pacemaker Via Right Internal Jugular Vein
    Kolek, Matthew J.
    Crossley, George H.
    Ellis, Christopher R.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (03) : 420 - 421
  • [5] Long-term electrical performance of the Micra™ leadless cardiac pacemaker
    Ebner, J.
    Kiblboeck, D.
    Boetscher, J.
    Maier, J.
    Kellermair, J.
    Reiter, C.
    Saleh, K.
    Kammler, J.
    Fellner, A.
    Lambert, T.
    Steinwender, C.
    Blessberger, H.
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (SUPPL 3) : S129 - S130
  • [6] Cautionary tale of right ventricular perforation during Micra™ leadless pacemaker insertion
    Gulkarov, Iosif
    Stein, Louis H.
    Karanam, Ravindranath N.
    Lackey, Adam
    Dobesh, David
    Ahmad, Ahsanuddin
    Salemi, Arash
    HEALTH SCIENCE REPORTS, 2022, 5 (06)
  • [7] Retrieval of a leadless transcatheter pacemaker from the right pulmonary artery: A case report
    Romeo, Emanuele
    D'Alto, Michele
    Cappelli, Maurizio
    Nigro, Gerardo
    Correra, Anna
    Colonna, Diego
    Sarubbi, Berardo
    Golino, Paolo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (05): : 952 - 954
  • [8] Anesthetic Consideration for Patients with Micra Leadless Pacemaker
    Karuppiah, Sathappan
    Prielipp, Richard
    Banik, Ratan K.
    ANNALS OF CARDIAC ANAESTHESIA, 2020, 23 (04) : 494 - 496
  • [9] Mortality After Micra Leadless Pacemaker Implantation
    Kamath, Akshay R.
    Heard, Brittney Z.
    Darby, Andrew E.
    Malhotra, Rohit
    Mangrum, James M.
    Bilchick, Kenneth C.
    Mason, Pamela K.
    Ferguson, John D.
    Mehta, Nishaki K.
    CIRCULATION, 2018, 138
  • [10] Is the new Micra-leadless pacemaker entirely safe?
    Da Costa, Antoine
    Romeyer-Bouchard, Cecile
    Guichard, Jean Baptiste
    Gerbay, Antoine
    Isaaz, Karl
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 212 : 97 - 99