Electrocatalytic oxidation of glucose on bronze for monitoring of saliva glucose using a smart toothbrush

被引:64
作者
Chen, Jian [1 ]
Zhu, Xiaofei [1 ]
Ju, Yinhui [1 ]
Ma, Biao [1 ]
Zhao, Chao [1 ]
Liu, Hong [1 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, State Key Lab Bioelect, Nanjing 210096, Jiangsu, Peoples R China
关键词
Bronze; Smart toothbrush; Glucose; Long term; Non-enzyme; ELECTROCHEMICAL DETECTION; AMPEROMETRIC DETECTION; GOLD; SENSOR; ELECTRODE; ANODE;
D O I
10.1016/j.snb.2019.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bronze is one of copper alloy materials that have been widely used not only in the Bronze Age, but also nowadays because they are hard, easy to cast and resistant against corrosion. For bronze, tin is commonly used as the major non-copper ingredient of bronze because of many highly desirable characteristics including the fact that metallic tin is not toxic. We find that the tin bronze is a suitable electrode material for non-enzymatic electrochemical glucose sensing in saliva. For electrocatalytic oxidation of glucose on the bronze electrode, a negative potential is applied for proton reduction which creates a temporary alkaline condition. The sensor has a linear range from 0 to 320 mu M with the regression equation: i = 11 + 0.015 C (i is the current in mu A and C is the concentration in mu M) with a correlation coefficient of 0.994. The sensitivity is found to be 480 mu A mM(-1) cm(-2), and the detection limit is 6.6 mu M with a signal-to-noise ratio of 3. The electrode is found to be highly selective towards glucose oxidation in the presence of interfering species such as ascorbic acid and uric acid. The electrochemical senor is integrated into a smart toothbrush for monitoring of saliva glucose, which is potentially useful for non-invasive screening of diabetes. Compared with other electrochemical glucose sensors, a naked bronze electrode is used as the working electrode to ensure the robustness of the sensor. No additional reagent is involved for the electrochemical determination of saliva glucose and the electrode can be regenerated simply by mechanically polishing for long-term uses.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 33 条
  • [1] [Anonymous], ELECTROANALYSIS
  • [2] Single step modification of copper electrode for the highly sensitive and selective non-enzymatic determination of glucose
    Babu, T. G. Satheesh
    Ramachandran, T.
    Nair, Bipin
    [J]. MICROCHIMICA ACTA, 2010, 169 (1-2) : 49 - 55
  • [3] The use of copper(II) oxide nanorod bundles for the non-enzymatic voltammetric sensing of carbohydrates and hydrogen peroxide
    Batchelor-McAuley, Christopher
    Du, Yi
    Wildgoose, Gregory G.
    Compton, Richard G.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) : 230 - 235
  • [4] Amperometric glucose biosensor based on ultrafine platinum nanoparticles
    Cao, Zhaoxia
    Zou, Yongjin
    Xiang, Cuili
    Sun, Li-Xian
    Xu, Fen
    [J]. ANALYTICAL LETTERS, 2007, 40 (11) : 2116 - 2127
  • [5] Cho S., 2010, ELECTROANAL, V19, P2315
  • [6] Electrocatalytic oxidation of methanol on Ni and NiCu alloy modified glassy carbon electrode
    Danaee, I.
    Jafarian, M.
    Forouzandeh, F.
    Gobal, F.
    Mahjani, M. G.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (16) : 4367 - 4376
  • [7] Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination
    El Khatib, K. M.
    Hameed, R. M. Abdel
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) : 3542 - 3548
  • [8] FLEISCHMANN M, 1972, J ELECTROANAL CHEM, V34, P499, DOI 10.1016/S0022-0728(72)80425-X
  • [9] CORROSION OF GOLD AND AMALGAM PLACED IN CONTACT WITH EACH OTHER
    FUSAYAMA, T
    NOMOTO, S
    KATAYORI, T
    [J]. JOURNAL OF DENTAL RESEARCH, 1963, 42 (05) : 1183 - &
  • [10] An Improved Sensitivity Non-enzymatic Glucose Sensor Based on a Nano-Gold Modified Ag Electrode
    He Jia-hong
    Xu Qiang
    Gao Zhi-qiang
    Song Zhong-rong
    [J]. MICRO-NANO TECHNOLOGY XIII, 2012, 503 : 427 - 431